SMC Corporation of America
Elite Part Number Search
Search Results "ZA1051-J15LB-P1-55"

(mm) D1 Note) A Weight (g) 6-applicable tubing D2 P2 L2 L3 M P1 L1 Model L1 1 8 1 4 3 8 1 8 1 4 3 8 1 8 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 KQ2ZT04-01S 18.5 54.5 50.5 25 31 44 27 33 46 56 54 62 P2 14 KQ2ZT04-02S 10.4 13.4 21 16 13.4 10.4 4 21.5 57.5 51.5 KQ2ZT04-03S 17 23.5 59.5 53.5 L2 P1 P1 D1 KQ2ZT06-01S 18.5 54.5 50.5 14 6 KQ2ZT06-02S 21.5 57.5 51.5 12.8 13.4 22 17 13.4 12.8 KQ2ZT06-03S

62.5 10.3 10.9 10.3 10.9 12.3 13.4 12.3 13.4 36.5 44 55 62.5 Note 1) ;in the table indicates the pad material "N, S, U, F, GN, GS."

V B A B A P1 Hysteresis setting trimmer 28.1 Pressure setting trimmer 28.5 25 15.8 8 Accessory (packed together) 1. Silencer (AN203-KM81 pc.) 51 26 16 2.

demand = 1000 n/min (N)VBA2, (N)VBA4 C H A R G E C H A R A C T E R I S T I C S NVBA1 C H A R G E C H A R A C T E R I S T I C S Charging time for 10l t(s) Charging time for 10l t(s) Pressure increase ratio (P2/P1) Pressure increase ratio (P2/P1) These graphs illustrate the time required to inrease pressure in a closed tank e.g.

Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: J1 (Supply: NC, Release: None), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: P1 (Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S.), Air Pressure

Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: J1 (Supply: NC, Release: None), Pilot Valve: Y (DC Low Wattage Type (0.5W), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: P1 (Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S.

Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: Supply: NC, Release: None, Pilot Valve: Standard (1W for DC), Power Supply Voltage: 24VDC, Electrical Entry: L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S., Air Pressure Supply, P Port

Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: Supply: NC, Release: None, Pilot Valve: DC Low Wattage Type (0.5W, Power Supply Voltage: 24VDC, Electrical Entry: L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S., Air Pressure Supply

105 120 140 77 96 113 53 60 74 26.5 30 37 120.5 137 160 20 24 24 129.5 147 170 170.1 187.6 210.6 211.5 229 252 55 63 74 Port size: Flange: 32F, 40F, 50F Standard/Vacuum pilot Applicable cable O.D. 6 to 8 (D, DZ) Pg9 Pilot port 12 (P1), 10 (P2) Port size: refer to table below Manual override (Non-locking push type) E P2 P1 C I (Grommet: G) J (DIN terminal: D, DZ) VNA H H VNB VNB D B (Air operated

A A A B A B P1 B B Section A-A (ejector) Section B-B (solenoid valve) Replacement parts list Parts list No. 1 2 3 4 5 6 7 8 Description Material No. Description Part No.

55 60.5 73 Note) ( ): CE-compliant product (-Q) Threaded Type/Port size: 32A, 40A, 50A Pg9 Applicable cable O.D. 6 to 8 Pilot port 12(P1), 10(P2) Port size: refer to table below F H (Air operated) J (External pilot solenoid) Light/surge voltage suppressor (For DZ) Manual override (Non-locking push type) P2 P1 E D 32 A K B C Main port 1(A) [Back side 2(B)] Port size: refer to table below

62.5 10.3 10.9 10.3 10.9 12.3 13.4 12.3 13.4 36.5 44 55 62.5 Note 1) ;in the table indicates the pad material "N, S, U, F, GN, GS."

How to Find the Flow Rate (at air temperature of 20C) Subsonic flow when P1 + 0.1013 < 1.89 (P2 + 0.1013) Q = 226S P(P2 + 0.1013) Sonic flow when P1 +0.1013 1.89 (P2 + 0.1013) Q = 113S (P1 + 0.1013) Q : Air flow rate [l/min (ANR)] S : Effective area (mm) P : Pressure drop (P1 P2) [MPa] P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] Correction for different air temperatures Multiply

Pilot port P1 and P2 piping Please arrange P1 and P2 piping as follows according to the model.

Analog Output Characteristics Hysteresia mode when the values of P1 and P2 are equal or when P1>P2 but within 3 digits, the hysteresis will be automatically set to 3 digits tor the set value ot P1. Window comparator mods The hysteresis is automatically set to 3 digits, so separate P1 trom P2 by 7 digils or more when programming.

Analog Output Characteristics Hysteresia mode when the values of P1 and P2 are equal or when P1>P2 but within 3 digits, the hysteresis will be automatically set to 3 digits tor the set value ot P1. Window comparator mods The hysteresis is automatically set to 3 digits, so separate P1 trom P2 by 7 digils or more when programming.

(Copper-free) VH VHS IN P1 Flow Rate and Effective Area OUT IN P2 VR1211F Model Metric size 6 3.2 4 Applicable tubing O.D. If air is only supplied only to either P1 or P2 it, does not flow to the OUT side.

Working Principle: Air Operated Type (PAF3413, 5413) Air supply port (AIR SUP) 5 port solenoid valve External solenoid valve P1 P2 Discharge port (FLUID OUT) Drive unit Pump chamber B Pump chamber A Check valve Shaft Suction port (FLUID IN) Drive chamber A Drive chamber B Diaphragm B Diaphragm A 1. When air is supplied to P1 port, it enters drive chamber A. 2.

N.C. 12 (P2) 12 (P1) 12 (P1) 12 (P1) VX2 VX (1) (2) (1) (2) (1) (2) (1) (2) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VX3 VXA VN LVC Wide selection of port size and variations LVA LVH Threaded type (6A to 50A) Flange type (32F to 80F) LVD LVQ LQ LVN Low water

v=l t P"p1 + 147 Where V = capacity of rceiver Q = compressor outpul (clm) Pa = atmosphric plsssurc P1 = compressor outsul pressure V = (600'14.7y(10O+14.7) =77lf as a minimum number, a prudent suggestion might begin with 120 ft".