SMC Corporation of America
Elite Part Number Search
Search Results "ZA1051-K15GB-P3-22"

Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: LO (L Plug Connector w/o Connector, Light/Surge Voltage Suppressor), Manual Override: B (Locking Type), Suction Filter: None, Pressure Sensor Specs: P3 (Pressure Sensor, -100 to 100kPa, Accuracy ±2% F.S.), Air Pressure

Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: J1 (Supply: NC, Release: None), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: P3 (Pressure Sensor, -100 to 100kPa, Accuracy ±2% F.S.), Air

Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: Supply: NC, Release: NC, Pilot Valve: Standard (1W for DC), Power Supply Voltage: 24VDC, Electrical Entry: L Plug Connector w/o Connector, Light/Surge Voltage Suppressor, Manual Override: Locking Type, Suction Filter: None, Pressure Sensor Specs: Pressure Sensor, -100 to 100kPa, Accuracy ±2% F.S., Air Pressure Supply, P Port: w/o Supply

Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: Supply: NC, Release: None, Pilot Valve: Standard (1W for DC), Power Supply Voltage: 24VDC, Electrical Entry: L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: Pressure Sensor, -100 to 100kPa, Accuracy ±2% F.S., Air Pressure Supply, P

Nozzle Nominal Size: ø0.7, Solenoid Valve Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: P3 (Pressure Sensor, -100 to 100kPa, Accuracy ±2% F.S.), Air Pressure

Nozzle Nominal Size: ø0.7, Solenoid Valve Combination: Supply: NC, Release: NC, Pilot Valve: Standard (1W for DC), Power Supply Voltage: 24VDC, Electrical Entry: L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: Pressure Sensor, -100 to 100kPa, Accuracy ±2% F.S., Air Pressure Supply, P Port

The pilot solenoid valve c remains energized (or pilot pressure remains applied to the port P3 of the air operated type).

P1 (P3) P2 (P4) P1 (P3) P2 (P4) Pressure low Pressure high Vacuum low Vaccum high Pressure low Pressure high Vacuum low Vacuum high Filter gasket (ZX1-FG) : Hysteresis mode (same as for positive pressure use) When the value of hysteresis is set to 2 digits or less, the switching output might chatter due to fluctuation of the input pressure around its set point.

When more than 3 types of nozzle are needed, A and B channels are available for selection; thus 2 outputs x 2 channels = 4 outputs are available. 50 ISA2 IS 0 0 Time AUTO-SHIFT terminal ZSM Set value of OUT2 (CH.B) Set value of OUT1 (CH.B) Set value of OUT2 (CH.A) Set value of OUT1 (CH.A) 10 [ms] Nozzle 1 Nozzle 2 Nozzle 3 Nozzle 4 50 GND PF2 P3 P4 P1 P3 P4 P1 After 10 [ms] is passed, display

A B ZCUK AMJ Rc 1/8 Rc 1/8 AFJ AMV P1 P1 ZH -X185 P1 P2 P3 Base part no. Adsorption surface size SP1130 SP1230 SP1330 SP1430 SP1530 SP1630 50 x 50 55 40 10 Related Products 100 x 100 95 50 10 P2 P3 P2 P3 150 x 150 120 75 10 200 x 200 145 100 10 Rc 1/8 Rc 1/8 P3 P3 250 x 250 170 125 10 300 x 300 195 150 10 Square Rc 1/8 Rc 1/8 P1 P2 Base part no.

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VACUUM EJECTOR, COMPACT, VACUUM SERIES, ZA COMPACT VACUUM EJECTOR, AG, ZA NOZZLE SIZE 0.5, .22308 lb

P3 [MPa]: Max. booster press. (Smaller one between inlet press. x Intensified press. ratio and Max. operating pressure.)

Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: J1 (Supply: NC, Release: None), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 6 (12VDC), Electrical Entry: G (Grommet w/0.3m Lead Wire), Manual Override: Non-locking Push Type, Suction Filter: F (Suction Filter), Pressure Sensor Specs: B (w/o Pressure Sensor), Air Pressure Supply, P Port: 2 (ø4, Straight), Vacuum, V Port: 2

Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: J1 (Supply: NC, Release: None), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: B (w/o Pressure Sensor), Air Pressure Supply, P Port: 2 (ø4, Straight

Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: B (w/o Pressure Sensor), Air Pressure Supply, P Port: 2 (ø4, Straight

Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: F (Suction Filter), Pressure Sensor Specs: B (w/o Pressure Sensor), Air Pressure Supply, P Port

Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: F (Suction Filter), Pressure Sensor Specs: P1 (Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S

Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: J1 (Supply: NC, Release: None), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: M (M Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: B (w/o Pressure Sensor), Air Pressure Supply, P Port: 2 (ø4, Straight

Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Y (DC Low Wattage Type (0.5W), Power Supply Voltage: 5 (24VDC), Electrical Entry: M (M Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: F (Suction Filter), Pressure Sensor Specs: B (w/o Pressure Sensor), Air Pressure Supply

Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: J1 (Supply: NC, Release: None), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: M (M Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: B (Locking Type), Suction Filter: F (Suction Filter), Pressure Sensor Specs: P1 (Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S.