If the input signal is not connected (open), the controller may be affected by the surrounding noise, and the circuit in the controller may incorrectly recognize that the input has been activated. 25 -
(2) Parallel I/O output circuit -NPN type Outside Inside the controller DC2(+)
Model B3 C1 14 20 22 C2 39 44 54 E1 1 1 1 E2 1 1 1 B1 28 40 44 78 88 108 96 111 131 MY-J25 MY-J32 MY-J40 8-11-29 29 Series MY1B Floating Bracket Facilitates connection to other guide systems. Applicable bore size Floating Bracket Operating Precautions Caution Make sure that the amount of divergence from the external guide is within the adjustable range.
Fixed mounting Pivot mounting DIN rail mounting bracket IZN10-B3 Single unit Manifold*1 *1 The L-bracket and the DIN rail mounting bracket can be used with the manifold.
OUT2 B3 OUT2 B4 OUT3 B4 OUT3 B5 OUT4 B5 OUT4 B6 OUT5 B6 OUT5 B7 BUSY B7 BUSY B8 AREA B8 AREA B9 SETON B9 SETON B10 INP B10 INP B11 SVRE B11 SVRE B12 ESTOP B12 ESTOP B13 ALARM B13 ALARM CN1 DC24V CN5 DC24V 27 - 7
Auto Switch Made to Order 62 C75 Series Dimensions of Accessories Rod End dH7 45 d3 b1 b3 l l3 d7 d6 h [mm] Bore size Part no. b1 b3 dH7 d6 d7 h l l3 d3 a 32 KJ10DA 14 10.5 10 28 19 43 20 15 M10 x 1.5 13 40 KJ12DA 16 12 12 32 22 50 22 17 M12 x 1.75 13 Floating Joint: JA M M U U D F G H B P E A [mm] Bore size Part no.
41 8.2 14 28 19.8 18 65.3 15.5 13 Up to 300 13 26 5 8 20 0 0.033 120 62 M26 x 1.5 30 15 M10 x 1.25 45 10.2 14 33.5 22 22 70.5 19.5 13 Up to 300 17 32 6 8 26 0 0.033 122 64 M26 x 1.5 34.5 15 M10 x 1.25 45 12.2 16 37.5 25.8 22 76.5 19.5 13 Up to 300 17 32 6 8 26 0 0.039 154 88 M32 x 2 42.5 21.5 M14 x 1.5 50 14.2 16 46.5 29.8 24 84.5 21 16 Up to 300 22 41 8 10 32 With Rod Boot h Bore (mm) B3
CM Note 1) L3 L4 L6 L8 L5 B3 B4 B6 B8 B5 Metric size Inch size Note 10) G1, G2, or G3 cannot be combined with N.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com S + Stroke ZZ + Stroke RHC MK(2) Built-in One-touch fitting One-touch fitting port size 6 RS Q G RS H A RZQ MI W S CEP1 CE1 With rod boot CE2 Width across flats B3 ML2B C J G5-S CV 9 9 l MVGQ ZZ + Stroke CC For DIN terminal and double solenoid, refer
CJ2 series (mm) HA 37 37 S 49 50 ZZ 114 115 Bore size (mm) 10 16 S + Stroke ZZ + 2 x Stroke HA + Stroke Width across flats B3 CM2 series Width across flats MA MM2 MI H3 MK 3 1.5 Stroke ML + Adjustment MT MH + Stroke + Adjustment ZZ + 2 x Stroke + Adjustment (A: 25 mm, B: 50 mm) CM2 Series (mm) B3 10 13 13 17 H3 3.6 5 5 6 MA 12 17 17 19 MI 14 20 20 25 MK 7 9 9 10 MM2 M6 x 1 M8 x 1.25 M8 x
With L-bracket B1 With pivoting bracket B2 With DIN rail mounting bracket B3 Output specification Refer to page 450.
115.5 D-F9, D-F9V (mm) Mounting patternq Bore size Mounting patternq A1 Mounting patternw A2 Mounting patterne A3 B1 A1 Operating range B1 B2 B3 (mm) 10 15 25 5.5 34 64 22 76 34 76 5 35 70 23 82 35 82 5 40.5 99.5 28.5 111.5 40.5 111.5 Mounting patternw B2 A2 D-F9W, D-F9WV (mm) Bore size Mounting patternq A1 Mounting patternw A2 Mounting patterne A3 Operating range B1 B2 B3 (mm) 10 15 25
B7 2 stations 02 M5 x 0.8 1/8 Tube Nil Rc G NPT NPTF F N T 20 stations 20 One-touch fitting for 4 One-touch fitting for 6 A port M5 x 0.8, 1/8, C4, C6, B3, B7 One-touch fitting for 5/32" One-touch fitting for 1/4 Note) For more than 9 stations, supply air to both sides of P port and exhaust air from both sides of R port.
B7 2 stations 02 M5 x 0.8 1/8 Tube Nil Rc G NPT NPTF F N T 20 stations 20 One-touch fitting for 4 One-touch fitting for 6 A port M5 x 0.8, 1/8, C4, C6, B3, B7 One-touch fitting for 5/32" One-touch fitting for 1/4 Note) For more than 9 stations, supply air to both sides of P port and exhaust air from both sides of R port.
Note: Be sure to take out the lead wire between the B2 and B3 terminals. Enlarged View WARNING Be sure to connect the regenerative resistor correctly. Do not short-circuit between B1/ and B2.
Note: Be sure to take out the lead wire between the B2 and B3 terminals. Enlarged View WARNING Be sure to connect the regenerative resistor correctly. Do not short-circuit between B1/ and B2.
D-B35 Reed switch Contacts protection resistance () () Current limiting resistance DDLight emitting diode (LED) Diode 1649 Series D-B3 Dimensions (mm) Terminal conduit type D-B3 Terminal conduit type D-B3J 42 42 500 G 1/2 59 38 59 38 6 41.5 41.5 85 69 35 35 42 8 8 59 1 2 85 Recommended minimum bending radius for lead wire RT : 25 mm or more 120C : 50 mm or more Terminal part Dimensions for
Insulation color Dot mark Dot color B1 Yellow Red B2 Light green Black B3 Light green Red B4 Gray Black B5 Gray Red B6 White Black B7 White Red B8 Light brown Black B9 Light brown Red B10 Yellow Black B11 Yellow Red B12 Light green Black B13 Light green Red Shield Conductor size: AWG28 Weight Product no.
40 CO 4 3 CR 24 30 CT 20 28 CU 100.025 0.047 120.032 0.059 32 40 7 10 9 12 34.5 46.8 42.5 58.2 6-10-33 34 Series C76 Accessary Dimensions [First angle projection] Single Knuckle Joint/DIN648-DIN 24335 Double Knuckle Joint/ISO8140-DIN71752 (mm) (mm) Thread e M10 x 1.5 M12 x 1.75 b 10 12 d 40 48 f 10 12 g 18 23 c 20 24 j 12 15 a 20 24 0 l3 14 16 Model GKM10-20A GKM12-24A h 43 50 d6 20 30 b3
Operating range CX B1 B2 B3 (mm) 10 15 25 5.5 34 64 22 76 34 76 Mounting pattern e DB3 A3 5 35 70 23 82 35 82 5 40.5 99.5 28.5 111.5 40.5 111.5 -X These values are given as a guideline including the hysteresis and are not guaranteed.
Mounting pattern e B3 A3 qWhen adjusting the stroke, confirm the minimum stroke for auto switch mounting. See the table below for the minimum stroke for auto switch mounting. Caution (mm) Minimum Stroke for Auto Switch Mounting (1 pc.) Minimum Stroke for Auto Switch Mounting (2 pcs.)