Bracket C MPa ISE20C(H) ISE20C: 0.050 MPa/ZSE20C: 5.1 kPa/ ZSE20CF: 5.0 kPa/ISE20CH: 0.100 MPa "Nil" or M Hysteresis Self tapping screws: Nominal size 3 x 8L kPa ZSE20C(F) Self tapping screws: Nominal size 3 x 10L Safety Instructions Bracket A ISE20C(H) Delay time 1.5 ms or less psi P ZSE20C(F) Display color OUT1 ON: Green/OUT1 OFF: Red : Arbitrary display These safety instructions are intended
Bracket C Units specification Pressure range Default setting ISE20C: 0.050 MPa/ZSE20C: 5.1 kPa/ ZSE20CF: 5.0 kPa/ISE20CH: 0.100 MPa Hysteresis ISE20C(H) MPa Self tapping screws: Nominal size 3 x 8L "Nil" or M Self tapping screws: Nominal size 3 x 10L ZSE20C(F) kPa Delay time 0.00 sec.
ZSE20C(F) is UL/CSA, CE and RoHS compliant.
Secondary battery capability is achieved by providing removing the bracket munting inserts found on the standard ZSE20C. 25a-ZSE20C(F) is UL/CSA, CE and RoHS compliant, with an IP65 rating.
Secondary battery capability is achieved by providing removing the bracket munting inserts found on the standard ZSE20C. 25a-ZSE20C(F) is UL/CSA, CE and RoHS compliant, with an IP65 rating.
ZSE20C(F) is UL/CSA, CE and RoHS compliant, with an IP65 rating.
ZSE20C(F) is UL/CSA, CE and RoHS compliant, with an IP65 rating.
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation
ZSE20C: ZSE20C, Rated Vaccum Range: F (-100 to 100 kPa), Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: M (SI Unit Only), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)]
And the ISE/ZSE20C series (for general purpose fluids) catalog can be found here.
ZSE20C(F)-L is CE and RoHS compliant, with an IP65 enclosure rating.
ZSE20C(F)-L is CE and RoHS compliant, with an IP65 enclosure rating.
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: C01 (Rc1/8), Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Rc1/8, Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation