9 Wear ring CM-020-07-301A CM-025-07-302A CM-032-07-304A C1A040-07-305A Resin @0 Piston gasket SO-012-13 SO-010-22 SO-010-23 SO-013-7 NBR @1 Cylinder tube gasket CM-020-16-123 CM-025-16-124 CM-032-16-126 CM-040-16-127 NBR @2 Rod seal PDU-10Z PDU-12LZ PDU-12LZ PDU-16Z NBR @3 O ring SO-017-30 SO-017-32 SO-017-34 SO-017-36 NBR @4 O ring SO-015-23 SO-015-23 SO-017-36 SO-017-37 NBR @5 4.10-10
%6 %7 %8 %9 ^1 ^2 ^3 ^4 ^5 ^6 ^8 Seal belt Dust seal band Scraper Piston seal Cushion seal Tube gasket O-ring O-ring O-ring O-ring O-ring Connector guide O-ring O-ring Special resin MY40-16A-stroke MY32-16A-stroke MY25-16A-stroke Stainless steel NBR NBR NBR NBR NBR NBR NBR NBR NBR NBR NBR NBR MY40-16B-stroke MY32-16B-stroke MY25-16B-stroke MYB40-15AA5902 GMY40 RCS-12 NLP-40A C-4 C-9 SO-015
%6 %7 %8 %9 ^1 ^2 ^3 ^4 ^5 ^6 ^8 Seal belt Dust seal band Scraper Piston seal Cushion seal Tube gasket O-ring O-ring O-ring O-ring O-ring Connector guide O-ring O-ring Special resin MY40-16A-stroke MY32-16A-stroke MY25-16A-stroke Stainless steel NBR NBR NBR NBR NBR NBR NBR NBR NBR NBR NBR NBR MY40-16B-stroke MY32-16B-stroke MY25-16B-stroke MYB40-15AA5902 GMY40 RCS-12 NLP-40A C-4 C-9 SO-015
L dimension 1.5 m 3 m 5 m AXT100-MC26-015 AXT100-DS25-015 AXT100-MC26-030 AXT100-DS25-030 AXT100-MC26-050 AXT100-DS25-050 When a commercially available connector is required, use a 25 pin female connector conforming to MIL-C-24308. L L (60) 44 Approx. 10 8 16 14 25 1 13 47.04 55 Multi-core vinyl cable 0.3 mm 2 x 25C 2 x M2.6 x 0.45 Terminal no. Socket side Plug terminal no.
LED EX245-DX1 LED(16 )(015) 015 OFF OFF ON ON ON . 7-2 EX245-DX1 LED 49 No.EX-OMW0014CN-A 7.6. EX245-DX1 8M12(5 ,) (n+1) (n) FE/ / . 7-3 EX245-DX1 50 No.EX-OMW0014CN-A 8.
LED EX245-DX1 LED16 015 015 OFF OFF ON ON ON . 7-2 LED 54 No.EX-OMU0020CN 7.6. EX245-DX1 8 x M12, 5-way sockets (0 to 7) Short circuit protection 24 V DI (n+1) Sensor interface 0V DI (n) FE / Sheild Input circuit / Bus interface 24 V (logic / sensors) 0 V (logic / sensors) 24 V (valves / loads) 0 V (valves / loads) FE BUS . 7-3 EX245-DX1 55 No.EX-OMU0020CN 8.
%6 %7 %8 %9 ^1 ^2 ^3 ^4 ^5 ^6 ^8 Seal belt Dust seal band Scraper Piston seal Cushion seal Tube gasket O-ring O-ring O-ring O-ring O-ring Connector guide O-ring O-ring Special resin MY40-16A-stroke MY32-16A-stroke MY25-16A-stroke Stainless steel NBR NBR NBR NBR NBR NBR NBR NBR NBR NBR NBR NBR MY40-16B-stroke MY32-16B-stroke MY25-16B-stroke MYB40-15AA5902 GMY40 RCS-12 NLP-40A C-4 C-9 SO-015
Bore (mm) Description Mounting nut Rod end nut SNPS-006 NTP-006 SNPS-010 NTP-010 SNPS-015 NTP-015 6 10 15 1.2-9 Series CJP Recommended Mounting Hole Dimensions for Plug Mounting Style Machining dimensions for Mounting When plug mounted Bore (mm) Stroke A B G F C E D 5 16 12.5 10 6 10 23 3 19.5 8.5 M10 X 1.0 17 3.5 15 30 26.5 24 5 17 13.5 10.5 10 10 23.5 4 12 20 M15 X 1.5 3.5 17 15 30.5 27
For details, refer to page 2-5-11. 2-5-10 11 Base Mounted Series VQ4000 Plug-in Unit Electrical wiring specifications D-sub connector assembly 015 030 050 Standard wiring Wiring with control unit AXT100-DS25D-sub connector Wire colors Terminal no. Terminal no.
Specify the wiring specifications on the manifold specification sheet. 12 12 stations Note 1) U D U D Note 2) Note 3) 2-6-10 11 Base Mounted Series VQ5000 Plug-in Unit Electrical wiring specifications Standard wiring D-sub connector assembly (AXT100-DS25) Wire colors 015 030 050 D-sub connector Terminal no.
U D U D Note) Indicate on a manifold specification h i f i d i 10 Base Mounted Type Series VQ5000 Electrical wiring specifications Standard wiring D sub connector assembly (AXT100-DS25) wire colors 015 030 050 D sub connector Terminal No. Polarity Lead wire color Dot marking 1 2 3 .
4No.PS-OMH0002CN-D () * (ISE70 ) SUS630SUS430SUS304 (ISE75(H)) ON/OFF (ISE70 ) (10 10 ) UL1310 UL1585 UL -5No.PS-OMH0002CN-D * (50 N ) , ,ISE70 40 NmISE75(H)80 Nm 1.52 FG *() 6 33 2 () ( etc.) 10 m10 m DC(-)() -6No.PS-OMH0002CN-D * () CE (FKM) * 2030 1 LCD * ()(), (ISE70 ) O -7No.PS-OMH0002CN-D ISE ISE ISE ISE ISE ISE ISE ISE 70 01 MPa 02 43 70 75H 02 43 2 75 010 MPa A 75H 015
L dimension AXT100-DS25-015 1.5m AXT100-MC26-015 1.5m AXT100-DS25-030 3m AXT100-MC26-030 3m AXT100-DS25-050 5m AXT100-MC26-050 5m When a commercially available connector is required, use a 25 pin female connector conforming to MIL-C24308. L (60) L 44 8 16 14 25 1 13 47.04 50 Approx. 10 Multi-core vinyl cable 0.3mm x 25Ca 2-M2.6 x 0.45 Terminal no. Socket side Plug terminal no.
U D U D Note) Indicate on a manifold specification h i f i d i 10 Base Mounted Type Series VQ5000 Electrical wiring specifications Standard wiring D sub connector assembly (AXT100-DS25) wire colors 015 030 050 D sub connector Terminal No. Polarity Lead wire color Dot marking 1 2 3 .
Includes (3)O-rings AFP 568-015 1 pr. AXT336-5j Ti+ RodsIndudes (2) M6X25 screws pr rod 2 NXT336-4-' Conduitcover Note: Not reouired it usino ME401 SLR end olates I AXT 3(]6-6 Gallrv blockino Disc AXT33G7A Blankslationkit AXT 3S5 Slop Valve (SV-1) sP0100 Inlerface Soeed Conlrol (use adder'M') AXT622-5A TminalBlock Manifolds Part No.
23 10 15 ZSM1-115 ZSM1-121 Pressure adjusting screw 52.5 500 Indicator light Indicator light R 1/8 16-10-2 3 Vacuum Switch Diaphragm Style Series ZSM1 Precautions Be sure to read before handling.
23 10 15 ZSM1-115 ZSM1-121 Pressure adjusting screw 52.5 500 Indicator light Indicator light R 1/8 16-10-2 3 Vacuum Switch Diaphragm Style Series ZSM1 Precautions Be sure to read before handling.
C I R C U I T ZSM1-115 H O W T O O R D E R V A C U U M S W I T C H S E R I E S ZSM1 ZSM1-121 ZSM1 ACCESSORIES CONTACT PROTECTION BOX ACCESSORIES V A C U U M S W I T C H S E R I E S ZSE1 C O N N E C T I O N Diaphragm type switches have no built-in contact protection circuit.
ISE70 ZSE80 ISE80 Terminal block box ZSE ISE ZSP PS ISA2 ISA2 With regulator + 2 port solenoid valve PSE With 2 port solenoid valve IS ISG ZSM1 Check optimum position at a glance.
ZSE10 ISE10 Reducing setting labor Minimizing risk of mistakes in setting ISE70 Copy Copy ZSE80 ISE80 PS ISA3 ISA2 ISE35 Master sensor 1 unit Slave side 2 units 10 units PSE 3-step setting 3-step setting IS ISG 1 2 3 ZSM1 Push Push Push Push Completion of setting Adjust to the set-value by the or button. Added vacuum range.