-/22-CA240 11-/22-CA250 11-/22-CA263 Relief type 50, 75, 100, 125, 3/8 Non-lube Double acting, single rod Air cushion Available 150, 200, 250, 300, 1/4 Vacuum suction type 350, 400, 450, 500 3/8 Note) Consult SMC for long stroke.
Trigger LV (7, 11) 1% Word10: Pushing speed Description Word Bit Signal name Input range Min. unit 10 0-15 Pushing speed (7, 11) 1 mm/s Word 11: Moving force Description Word Bit Signal name Input range Min. unit 11 0-15 Moving force (7, 11) 1% Word12, 13: AREA 1 Description Word Bit Signal name Input range Min. unit 12 0-15 AREA 1 (Lower digits) Basic parameter "Stroke (-)" "Stroke (+)"
M8 x 1 40.8 11 14 29 18 9.5 7 5 MXQR-JS12 1.4 7 46.7 MXQR-BS16 MXQR16 M5 x 16 21 16 13.5 14 M10 x 1 M5 x 16 23 13.5 17 36 11 22 9 6 45.3 MXQR-JS16 11 67.3 MXQR-BS20 MXQR20 M6 x 20 25 22 17 19 M14 x 1.5 M6 x 18 27 12 17.5 22 46 13 35 10 67.1 MXQR-JS20 12 67.3 MXQR-BS25 MXQR25 M8 x 20 31 22 19 19 M14 x 1.5 M8 x 18 33 12 18 22 54 16 35 10 67.1 MXQR-JS25 1) Size of hexagon socket head bolt 2
2 e (1 pc.) @0 10-11-11 11 Series MIW/MIS Dimensions: Double Finger Type MIW-D 2-P Supply port 3-LA Scraper mounting thread EB FB NB ME PE GD LB JA B FA FC GC GB JB Mounting hole 4-GA LC C EA D 2-P Attachment mounting thread 4-FD through Supply port PD NA FF FE PC PA A Mounting threads 4-MA thread depth MB Groove position for auto switch mounting HB depth HC HD (2 pcs.)
The installation torque is 0.3 to 0.5 Nm. 14-11-15
2 e (1 pc.) @0 10-11-11 11 Series MIW/MIS Dimensions: Double Finger Type MIW-D 2-P Supply port 3-LA Scraper mounting thread EB FB NB ME PE GD LB JA B FA FC GC GB JB Mounting hole 4-GA LC C EA D Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 2-P Attachment mounting
9.4.1 HRR050-A-20. 9-11 9.4.2 HRR050-W-20. 9-11 9.4.3 HRR050-A-40. 9-12 9.4.4 HRR050-W-40. 9-12 9.5 Heating capacity . 9-13 9.5.1 HRR050-A/W-20. 9-13 9.5.2 HRR050-A/W-40. 9-13 9.6 Pump capacity. 9-14 9.6.1 HRR050-A/W-20. 9-14 9.6.2 HRR050-A/W-40. 9-14 9.7 Required facility water flow (for water-cooled type) . 9-15 9.7.1 HRR050-W-20. 9-15 9.7.2 HRR050-W-40. 9-15 9.8 Types of Hazard Labels
Internal circuits D-Y7NW(V) Weights DC(+) Brown [Red] (g) Main circuit of switch OUT Black [White] Lead wire length Auto switch part no. 3m 0.5m 54 11 D-Y7NW, D-Y7NWV, D-Y7PW, D-Y7PWV DC() Blue [Black] 54 11 D-Y7BW, D-Y7BWV Dimensions D-Y7PW(V) D-Y7NW, D-Y7PW D-Y7BW M2.5 x 4 Slotted set screw DC(+) Brown [Red] 2.5 Indicator light Main circuit of switch 3.4 OUT Black [White] SMC SMC 6.2 5
3H9 2.5 deep +0.025 0 5 M 0.5 18 20 Z ZZ (NN-1) x H G H 11 5.5 5.5 11 A B 3.2 6.5 7 7 12 4 NN-M4 x 0.7 thread 8 deep A B 3H9 2.5 deep +0.025 0 3H9 2.5 deep +0.025 0 HA GA Section AA Section BB (mm) Model F 20 30 20 28 38 GA 11 21 31 43 41 HA 20 20 20 30 48 N 4 4 6 6 6 G 6 6 11 13 17 H 25 35 20 30 24 NN 2 2 3 3 4 I 10 10 7 19 25 J 17 27 40 50 60 K 22.5 32.5 42.5 52.5 62.5 Z 41.5 51.5 61.5
16 12 58 107 34 33 70 3/8 58 40 12 19 47 8 22 22 19 50 65 103 M8 x 1 32 64.5 9 M20 x 1.5 25 to 800 11 16 12 58 108 50 42 15 34 59 11 83 3/8 65 24 28 28 25 63 77 115 M8 x 1 38 76.5 9 M27 x 2 25 to 800 11 50 19 31 18 74 12 95 1/2 66 115 68 58 13 36 30 32 36 80 M10 x 1.25 25 to 800 96 147 47.5 95.5 10.5 M33 x 2 14 60 42 17 18 121 1/2 74 133 77 13 80 75 45 41 17 41 45 100 25 to 1000 115 179
-102 to 103 13-11-104 to 105 13-11-106 to 110 13-11-106 to 110 13-11-111 to 112 13-11-113 to 116 Buffer stroke Adsorption is possible even on a slanted surface.
Blue(DC COM) 11 Terminal No. Black (Output1) 3 Terminal No. Black(Output1) Fig. 3-12 Wiring of the external switch (NPN open collector output) (example) Flow switch Blue(DC COM) Brown (DC 24V) Brown(DC 24V) 14 Terminal No. Blue(DC COM) 6 Terminal No. Flow switch 13 Terminal No. 3 Terminal No. Black(Output1) Black (Output1) 11 Terminal No.
R 11 R 11-1 11-2 1 AC100V AC200V INOUT IDU8E15E1-10-R IDU15E1-20/23-R IDU8E/11E-20/23-R (A) 10 5 (mA) 30 11-3 M5 9.5mm 2 1.25mm L ,N N L () () IDU Series 11-1 11 1 IDX-OM-W023 11 R AC100V M4 () AC200V (M3) 17 11-4 () () ONOFF 11-5 1-1 IDU Series 11-4 11 2 IDX-OM-W023 12.S 12 S 12-1 IDU8E15E1-10 IDU Series 12-1 IDX-OM-W023 12.S 12-2 L N PE M3 6.5mm 2 1.25mm
Specification for Option R 11 1 Safety instructions .11 1 11 2 Specifications .11 1 11 3 Power supply connection procedure .11 2 11 4 Cautions for handling the GFCI .11 3 11 5 Electric circuit .11 3 Chapter 12 Specification for Option S 12 1 Safety instructions . 12 1 12 2 Specifications . 12 1 12 3 Electric circuit . 12 1 Chapter 13 Specification for Option T 13 1 Safety instructions .
Blue(DC COM) 11 Terminal No. Black (Output1) 3 Terminal No. Black(Output1) Fig. 3-14 Wiring of the external switch (NPN open collector output) (example) Flow switch Blue(DC COM) Brown (DC 24V) Brown(DC 24V) 14 Terminal No. Blue(DC COM) 6 Terminal No. Flow switch 13 Terminal No. 3 Terminal No. Black(Output1) Black (Output1) 11 Terminal No.
RR S U 0.040 0.076 0.040 0.076 0.040 0.076 0.040 0.076 0.050 0.093 0.050 0.093 0.065 0.117 0.065 0.117 20 8 132 141 7 9 2 14 30 27.6 21 3 56.5 42 30 153 CG-E020SUS 9 83 13 25 8 137 146 7 9 2 14 30 27.6 21 3 56.5 42 30 158 CG-E020SUS 9 83 13 32 10 141 7 11 4 22 40 38.4 29 4 70.5 56 40 170 152 CG-E032SUS 11 85 15 40 10 159 7 11 4 22 40 38.4 29 4 70.5 56 40 188 170 CG-E032SUS 11 93 15 50 14
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 3 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 4 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Low level in tank 1 High circulating fluid discharge temp. 2 Circulating fluid discharge temp. rise 3 Circulating fluid discharge
How to Calculate the Flow Rate SOL.A VQZ100-47-A For obtaining the flow rate, refer to pages 2-1-8 to 2-1-11.
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 3 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 4 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Low level in tank 1 High circulating fluid discharge temp. 2 Circulating fluid discharge temp. rise 3 Circulating fluid discharge
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 3 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 4 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Low level in tank 1 High circulating fluid discharge temp. 2 Circulating fluid discharge temp. rise 3 Circulating fluid discharge