SMC Corporation of America
Elite Part Number Search
Search Results "22-CDJ2B6-15R-H7B"

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 410, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: High speed / high frequency, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1.0, Port thread type: Rc, Auto Switches: H7B, Lead Wire Length(m): 3,

Magnet: Built-in, Mounting: Basic, Bore Size: Ø10 (3/8"), Stroke: 1/2", Port Location: In-line, Auto Switch: H7B--Solid State, Gen. Purpose, 2 Wire, Lead Wire, 0.5M, Number: 1 pc.

Magnet: Built-in, Mounting: Basic, Bore Size: Ø10 (3/8"), Stroke: 1", Port Location: Perpendicular, Auto Switch: H7B--Solid State, Gen. Purpose, 2 Wire, Lead Wire, 0.5M, Number: -

Magnet: Built-in, Mounting: Basic, Bore Size: Ø10 (3/8"), Stroke: 1", Port Location: In-line, Auto Switch: H7B--Solid State, Gen. Purpose, 2 Wire, Lead Wire, 0.5M, Number: -

Magnet: Built-in, Mounting: Basic, Bore Size: Ø10 (3/8"), Stroke: 1 1/2", Port Location: Perpendicular, Auto Switch: H7B--Solid State, Gen. Purpose, 2 Wire, Lead Wire, 0.5M, Number: -

Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: H7B

Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: H7B

Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: H7B

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 1.0, Specification: Built-in magnet, Auto Switches: H7B, Lead Wire Length(m

Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Auto Switches: H7B

Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Auto Switches: H7B

Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Auto Switches: H7B

Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Auto Switches: H7B

Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Auto Switches: H7B

Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Auto Switches: H7B

Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Auto Switches: H7B

Inner Diameter(φ): 50, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): null~1.0, Port thread type: Built-in one-touch fittings type, Auto Switches: H7B

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 280, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.2~1.0, Port thread type: Rc, Auto Switches: H7B, Lead Wire Length(m): 0.5, The number of the

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: H7B, Lead Wire Length

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: H7B, Lead Wire Length