/I.D. 1.4 MPa Fluid Air/Water (5) Maximum operating pressure (at 20C) 1.5 MPa 1 MPa 1.5 MPa 1 MPa 0.8 MPa 5 to 60C, Water: 0 to 40C (No freezing) Ambient and fluid temperature Connection size M5, R1/8 JIS B0205, Class 2 (Metric fine thread) M5 JIS B0205 (Metric fine thread) JIS B0203 (Taper thread for piping) Thread Note 1) Soft nylon tubing is not compatible with water.
response frequency Green LED (stable detection) Red LED (unstable detection) Red LED (lights up when ON) Indicator light Ambient temperature 10 to 55C 25 to 70C Environmental resistance Ambient humidity 45 to 85% RH Power line: 240Vp, pulse width of 0.5s Noise resistance Temperature characteristics Voltage characteristics Detecting distance fluctuation Within +15/10% of detecting distance at 20C
(mm) Effective area (mm2) Weight (g) Port size Flow rate (/min (ANR)) Flow rate (/min (ANR)) Flow rate (/min (ANR)) AS2000E-01 AS2000E-02 AS3000E-02 AS3000E-03 AS4000E-02 AS4000E-03 AS4000E-04 90 1/8 1/4 1/4 3/8 1/4 3/8 1/2 3.8 250 5.2 340 20, 25, 32, 40 115 12.3 810 12.3 32, 40, 50, 63 810 130 40, 50, 63 80, 100 25.5 1670 25.5 1670 225 Note) Flow rate values are measured at 0.5 MPa and 20C
Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 5 to 60C (No freezing) Ambient and fluid temperature 8 turns Number of needle rotation 130 g (Metallic handle: 140 g) Weight Flow rate (/min (ANR)) 810 Free flow 12.3 Effective area (mm2) Flow rate (/min (ANR)) 810 Controlled flow 12.3 Effective area (mm2) Note) Flow rate values are measured at 0.5 MPa and 20C
ASF JIS Symbol Flow Rate and Effective Area ASP330F ASP430F ASP530F ASP630F Model 10 12 8 8 10 Metric size 6, 8 6 1/4" 5/16" 1/4" 5/16" 3/8" 3/8" 1/2" Tubing O.D. 5/16" Inch size Flow rate (/min(ANR)) Controlled flow (Free flow) 180 600 750 1100 1190 330 350 Effective area (mm2) 9.3 11.6 17 18.4 2.9 5.2 5.4 Note) Flow rate values are measured at 0.5 MPa and 20C.
operating pressure 5 to 60C (No freezing) 10 turns 10 turns 8 turns Ambient and fluid temperature Number of needle rotation Hexagonal lock nut With seal, Hexagonal lock nut, Nickel plated Option 181 106 64 29 10 6 3 Weight (g) 20 0.3 1700 26 920 14 460 7 230 3.5 105 1.6 Flow rate /min (ANR) Controlled flow (Free flow) Effective area (mm2) Note 1) Flow rate values are measured at 0.5 MPa and 20C
12.3 810 12.3 32, 40, 50, 63 124 AS3000-03 3/8 810 12.3 810 12.3 221 AS4000-02 1/4 1,670 25.5 1,670 25.5 40, 50, 63 80, 100 214 AS4000-03 3/8 1,670 25.5 1,670 25.5 205 AS4000-04 1/2 1,670 25.5 1,670 25.5 242 AS5000-02 1/4 2,840 44 2,840 44 40, 50, 63 80, 100 233 AS5000-03 3/8 4,270 66 4,270 66 224 AS5000-04 1/2 4,270 66 4,270 66 AS4000 Note) Flow rate values are measured at 0.5 Mpa and 20C
3,600 55 0.34 AS420-03 5,000 3/8 77 4,800 74 0.33 63, 80, 100, 125 AS420-04 6,600 1/2 100 6,700 102 0.32 AS500-06 10,100 3/4 154 8,100 123 140, 160, 180, 200 0.36 AS600-10 15,100 1 230 16,900 258 160, 180, 200, 250 0.7 AS800-12 1 4 35,400 1 540 38,500 586 1.4 AS900-14 1 2 52,000 1 792 47,500 724 300 3.3 AS900-20 57,800 2 880 60,800 926 3.3 Note) Flow rate values are measured at 0.5 MPa and 20C
ANR: 20C atmospheric pressure, relative humidity 65% 200 300 1,000 1 4 3 8 1 4 3 4 1 2 , , 0.12 AMC-EL2 BE20 0.2 AMC-EL3 BE30 0.5 AMC-EL5 BE50 VEX How to Order AN 5 1 0 AMC 06 AMC Thread Body size Suffix Port size 1 4 std. 3 8 std. 3 4 1 std. std. 1 2 2 std. 2 std. 3 5 6 8 9 B With bracket 1 2 14 20 1 1 02 Female Female Male Female Female Male 1 Male thread 10 1 4 Male Male Male D Drain piping
(Coil temperature: 20C, at rated voltage, without surge suppressor.) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Impact/Vibration resistance (m/s2) Note 2) 150/30 Dustproof Enclosure Note 1) Based on dynamic performance test JIS B8374-1981 (Standard type: at coil temperature of 20C, with rated voltage, without surge voltage suppressor) Note 2) Impact resistance:
(Coil temperature 20C, at rated voltage, without surge voltage suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
(Coil temperature: 20C, at rated voltage, without surge voltage suppressor) When equipped with DC solenoid/surge voltage suppressor, a delay of about 20 to 30 m/sec. occurs in the OFF response time.
(Coil temperature: 20C, at rated voltage, without surge voltage suppressor) Note 2) This solenoid valve requires lubrication. Use turbine oil Class 1 (ISO VG32).