SMC Corporation of America
Elite Part Number Search
Search Results "CD85KN10-50-A"

Auto switch model Bore size [mm] 20 25 32 40 D-M9m(V) D-M9mW(V) BM8-020 (A set of a, b, c, d) BM8-025 (A set of a, b, c, d) BM8-032 (A set of a, b, c, d) BM8-040 (A set of a, b, c, d) BM8-025S (A set of a, b, c, d) * S: Stainless steel set screw BM8-032S (A set of a, b, c, d) * S: Stainless steel set screw BM8-040S (A set of a, b, c, d) * S: Stainless steel set screw D-M9mA(V) BM8-020S (A

(Non-locking) 55.5 [62] 43.1 36.5 25.5 49 A A 19 9.5 21 (Pitch) n-Rc (PT)1/8 P=17 21 (A port) A A 19 9.5 18.5 (Pitch) n-M5 X 0.8 P=16 16 (A port) [ ] for AC Other dimensions are the same as the M5.

B A B A B A PB PB Double acting N.C. N.O. N.O. Double acting Double acting With flow rate adjustment PA PA B A PB B A N.C. Double acting With bypass PA PA N.C. PB B A B A Double acting N.C. Double acting With flow rate adjustment & by-pass PA PA N.C. B A PB B A Double acting N.C. Double acting With indicator PA N.C. B A N.C. Manifold (5 stations max.)

VN Solenoid valve option Nil Standard Rated voltage 1 2 3 4 5 6 7 8 9 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz Other (Please contact SMC separately.) LVC Select an option mark in page 17-3-9 by Applicable Fluids Check List for special fluids outside of the standard.

Normal output Reversed output -100No.PF-OMA1011-A Specifications Model PFG20# series PF2A5 PF3W5 PF2D5 Applicable flow sensor 10 50 11 21 51 04 20 40 11 25 04 20 40 Rated flow range 1 to 10 5 to 50 10 to 100 20 to 200 50 to 500 0.5 to 4 2 to 16 5 to 40 10 to 100 50 to 250 0.4 to 4 1.8 to 20 4 to 40 L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min 0.35 to 1.7 to

of arm section) L1 = 50 [mm] L2 = 40 [mm] a m L2 Item Load factor n Note zLoad mass 1 = m/mmax = 0.5/5 = 0.1 Investigate m.

Y: 4.5 to 7 D: 6 to 8 50 37.5 2(A) 2(A) 11 (A port) Rc 1/4 Stations L L1 L2 Formula 2 83.5 68.5 3 111 96 5 166 151 7 221 206 9 276 261 4 6 8 10 : With light/surge voltage suppressor ( ): Dimensions for external pilot L1 = 27.5 x n + 28.5 138.5 193.5 248.5 303.5 L2 = 27.5 x n + 13.5 123.5 178.5 233.5 288.5 4-8-13 Dimensions: VV3P5 (For N.C.)

Applicable for pressure detection with a wide range of fluids, by using a stainless steel diaphragm. 16-2-25 2 Pressure detection for a wide range of fluids.

Auto switches / Proper mounting position for stroke end detection Electrical entry direction: Inward Electrical entry direction: Outward B D C A (mm) D-Z73 D-Y59A,D-Y59B A B C D Bore size D 0.5 4 0.5 3 5 5 C 16.5 23 34 46 46.5 56 6 20.5 27 38 50 50.5 60 -1 2.5 -1 1.5 3.5 3.5 32 15 21.5 32.5 44.5 45 54.5 4.5 8 4.5 7 8.5 9 10 15 20 25 Note 1) The above mentioned values are indicated as a guide

4 (A) 4 1 (P) 3 (R) 5 (R) 1 (P) 3 (R) How to Order Manifold Base 2 position double 2 position double (B) 2 (A) 4 (B) 2 (A) 4 Same manifolds as series SYJ3000 are prepared. 1 (P) 3 (R) 5 (R) 1 (P) 3 (R) SS5YJA3 Fill the same as SS5YJ3 3 position closed center 3 position closed center (B) 2 (A) 4 (B) 2 (A) 4 Instruct by specifying the valves and blanking plate assembly to be mounted on the

2) 2 1 110 VAC 50/60 Hz 200 VAC 50/60 Hz 100 VAC 50/60 Hz Orifice dia.

HS Auto switch Auto switch 12 8.5 24.5 16 A B A B 33 38.2 Auto switch mounting position Auto switch mounting height (mm) (mm) Auto switch model D-C7, C8 D-H7 D-H7W D-H7F D-H7BA D-H7 D-H7C D-H7W D-H7BA D-C7, C8 D-C73C D-C80C D-B5, B6 D-C73C D-C80C D-B5, B6 D-B59W D-G5NT D-H7C D-G5NT D-B59W D-H7F Bore size (mm) A A B A B A A HS HS HS B B B B A 20.5 (28.5) 14.5 (22.5) 17.5 (25.5) 19.5 (27.5)

CCW 50mm =0() =10 50mm CCW CW 0 10 20 30 40 50 [mm] 50mm CCW CW 10 20 30 40 50 60 [mm] b) CW )50mm =0() =10 =-10 50mm CCW CW -50 -40 -30 -20 -10 0 [mm] 50mm CCW CW -40 -30 -20 -10 0 10 [mm] 50mm CCW CW -60 -50 -40 -30 -20 -10 [mm] -29- 4/ A 50mm () 5m 5m 10% 15m 20% -30- 5./ 5.1 (LEC ) ,, () EMG() 1000 1 / (Best Pneumatics No UL ,UL1310 Class2 -31- 5.2 5.3. 90100 DC24VSVON

Calculate the moment of inertia for A and B separately as shown in the figures on the right. A part B part Procedure Calculation Calculation example 1. Check the operating conditions, dimensions of attachment, etc. Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.

-32D MHW2-40D MHW2-50D 40 MHY2-10D MHY2-16D MHY2-20D MHY2-25D Gripping point 100 30 20 50 10 0.4 0.5 0.6 0.7 0 0 0.1 0.2 0.3 0.1 0.2 0.4 0.5 0.3 0.6 Gripping point Pressure P (MPa) Pressure P (MPa) Workpiece should be held at a point within the range of overhanging distance (H) for a given pressure indicated in the tables on the right.

/60Hz) 2 200V AC (50/60Hz) 3 110V AC (50/60Hz) 4 220V AC (50/60Hz) 5 24V DC 6 12V DC 7 240V AC (50/60Hz) 9 Other Option Body size Port size Electrical entry (Only solenoid) Port size Rc(PT) P, A port R port Body size Electrical entry Port 01 1 02 VEX 1 8 1 8 G Grommet (300mm lead wire) 1 4 1 4 H Gromet (600mm lead wire) 02 3 03 1 4 1 4 D DIN connector 3 8 3 8 DO DIN connector (Without connector

MY-SA 2-G E MX F 2-H B A D C MTS MY Side support B MY-SB CY MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 2-J CX E DB A C D -X (mm) 20B A 53 77 112 160 C 15 35 45 55 D 26 50 64 80 E 4.9 8 11.7 14.8 F 3 5 6 8.5 G 6.5 9.5 11 14 H 3.4 5.5 6.6 9 J M4 x 0.7 M6 x 1

VQZ (A) 2 (A) 2 VZ 3 (R) 1 (P) 3 (R) 1 (P) VS VFN r e w q r e w q N.O. N.O. (A) 2 (A) 2 3 (R) 1 (P) 3 (R) 1 (P) Component Parts No.

of friction between the attachment and work, select a model that can produce a holding force 10 to 20 times the work weight.

300 400 5 10 50 100 10 50 100 Eccentric distance l (mm) Eccentric distance l (mm) Stroke (mm) Stroke (mm) How to read the graph 1) When the load weight is 70 kg, eccentric distance is 60 mm, and the maximum speed is 150 mm/s Select MGF100 from Graph (7). 2) When MGF63 is operated with a load weight 30 kg and 100 mm eccentric distance From Graph (6), the cylinder can be used at a maximum