Actuators -ARP20/ARP20K 10 21 -ARP30/ARP30K 10 21 -ARP40/ARP40K 10 21 Clean room compliant, copper-free, fluorine-free, silicone-free Air Preparation Equipment Clean room compliant Description Symbol Body size Body size 30 20 40 20 40 30 Nil 1 Note 4) 3 Note 4) Set pressure c 0.005 to 0.4 MPa setting 0.005 to 0.2 MPa setting 0.008 to 0.6 MPa setting + Semi-standard Nil R Flow direction d
Applications) Direct Operated Precision Regulator with Backflow Function (For Special Applications) Series ARP20K to ARP40K 10 20 2110 20 21-ARP20/ARP20K 10 20 21 -ARP30/ARP30K 10 20 21 -ARP40/ARP40K 10 20 21 Description Symbol Body size 20 30 40 Nil 1 Note 4) 3 Note 4) Set pressure c 0.005 to 0.4 MPa setting 0.005 to 0.2 MPa setting 0.008 to 0.6 MPa setting + Semi-standard Nil R Flow direction d
NPN(1 )+ (15 V) PF2A7--29--X560 NPN(1 )+ (420 mA) 22 PF2A7--68--X560 PNP(1 )+ (15 V) PF2A7--69--X560 PNP(1 )+ (420 mA) / ZS-37-A () 3 m 100 g ZS-37-B (L ) 3 m 100 g ZS-29-T 4 (312 ) 40 g -11No.PF-OMO0007CN (IN ) 1 DC(+) 2 OUT2 3 DC(-) (OUT ) 4 OUT1 INOUT (UP) (SET) (DOWN) LED (OUT1) (OUT2) (OUT1) LED (OUT1) OUT1 ON (OUT2) OUT2 ON (UP) ON/OFF (SET) (DOWN) ON/OFF -12No.PF-OMO0007CN D
[F 2] OUT2 -37No.PF-OMN0011CN-C d. ([ tP]) 4. [F 2] OUT2 e. ([ tPL]) [ tPH] or [ tnH] ([ tPH]) 4.
D Not available at 80 and 100. Note) Mounting brackets are not mounted and are supplied loose at the time of shipment.
e f g Nil Reed switch L R Solid state switch S h Nil L R S Operating direction Left Right a b h g d c f e Note) Lead wire length symbols 0.5m .
Magnet: D (Built-in), Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 180mm, Thread: TN (NPT), Stroke: 400mm, Option: N (w/o Cushion), Cylinder Switch Type: M9PV--Solid State , Gen.
Magnet: D (Built-in), Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 180mm, Thread: TN (NPT), Stroke: 400mm, Option: N (w/o Cushion), Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs.
Magnet: D (Built-in), Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: TN (NPT), Stroke: 150mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs.
Magnet: D (Built-in), Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: Rc, Stroke: 600mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs.
Magnet: D (Built-in), Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: TN (NPT), Stroke: 300mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs.
Magnet: D (Built-in), Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: TN (NPT), Stroke: 300mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs.
Magnet: D (Built-in), Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: TN (NPT), Stroke: 700mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs.
Magnet: D (Built-in), Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: TN (NPT), Stroke: 800mm, Option: J (Nylon Tarpaulin Rod Boot & Cushion at Both Ends), Cylinder Switch Type: M9PWV--Solid State, 2-color Indication, 3 Wire PNP, Vertical, Lead Wire or Pre-wired Connector: SAPC (0.5m
Magnet: D (Built-in), Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: TN (NPT), Stroke: 800mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9PWV--Solid State, 2-color Indication, 3 Wire PNP, Vertical, Lead Wire or Pre-wired Connector: MAPC (1.0m Cord Length, M8-3 Pin Connector
Magnet: D (Built-in), Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 180mm, Thread: TN (NPT), Stroke: 700mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs.
Magnet: D (Built-in), Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 140mm, Thread: Rc, Stroke: 100mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs.
Magnet: D (Built-in), Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 140mm, Thread: Rc, Stroke: 150mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs.
Magnet: D (Built-in), Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: TN (NPT), Stroke: 700mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Pre-wired Connector: Z (5m Lead Wire), Number: 2 pcs.
Magnet: D (Built-in), Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: TN (NPT), Stroke: 600mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Pre-wired Connector: Z (5m Lead Wire), Number: 2 pcs.