T NPTF Coil rated Electrical entry 3 8 G F 1 100 VAC, 50/60 Hz Grommet Nil T Conduit terminal Standard 4 1 2 Option 2 200 VAC, 50/60 Hz Port size Manual override P None Nil Option WTB Dripproof conduit terminal 3 110 VAC, 50/60 Hz 1 4 Rc 3 8 Rc 1 2 Rc 3 4 Rc 02 03 04 06 TZ Conduit terminal w/ surge voltage suppressor 4 220 VAC, 50/60 Hz How to Calculate the Flow Rate 5 24 VDC 9 Other TL
Options J: With drain guide M Mounting Dimensions Model Port Size (Nominal size B) A G F E D C B S 1.6 2.0 2.0 2.3 2.3 3.2 3.2 4.5 4.5 R 4.5 5 5 5 5 9 9 10 12 Q 26 28 28 34 34 50 50 60 76 P 70 84 84 100 100 110 110 130 180 O 54 66 66 80 80 88 88 102 136 N 35 40 40 50 50 55 55 65 85 L 9 12 12 14 14 14 14 16 20 K 5 8 8 8 8 10 10 10 15 J 15 20 17 22 19 25 21 30 40 I 56 66 66 80 80 90 90 100
Thus, F= 5 x 0.05 x 9.8 = 2.5 (N) 70 Lateral load F (N) 60 0.4MPa 50 40 2. Confirmation of allowable lateral load From the graph, the allowable lateral load at L=50mm and P=0.4MPa is 18N. 2. Confirmation of allowable lateral load In the same way, the lateral load at L=50mm and P=0.4MPa is 48N from the graph.
Thus, F= 5 x 0.05 x 9.8 = 2.5 (N) 70 Lateral load F (N) 60 0.4MPa 50 40 2. Confirmation of allowable lateral load From the graph, the allowable lateral load at L=50mm and P=0.4MPa is 18N. 2. Confirmation of allowable lateral load In the same way, the lateral load at L=50mm and P=0.4MPa is 48N from the graph.
(+) -F OUT1 PNP 1 Max.80 mA 1 V 12 V 300 24 V 600 50 OUT2 FUNC DC(-) -20No.PS-OML0002CN-G 1 1 1 1 ONOFF ON OFF ON P_1 H_1 [Pa] ON OFF [] -21No.PS-OML0002CN-G <> 1 [P_1][n_1] 1 1 -22No.PS-OML0002CN-G 2[P_2][n_2] (P1LP1H) P1L()P1H() (n1Ln1H) 1 -23No.PS-OML0002CN-G 2[F 0] [F] 2 2 [F][-] [F 0] 26 ISE30A MPa ""M ZSE30A(F) kPa ISE30A P ZSE30A(F) psi [F 1] OUT1 27
VNl VQ 1 (P) N.C. Note 5) DIN connector style: Applicable to dust and jet proof (IP65).
D-SMC, P-63 (M) 2nd printing September 1996. D-SMC, P-59(YG) March 1997. 29(YG) Printed in Japan.
Manual override P L 5 24 VDC 02 Rc 1/4 (8A) Rc 3/8 (10A) 9 Other 03 3-9-1 2 Series VS410 Accessory (Option) Apparent Power (Power Consumption) 1.
through Q R E GB GA 4-NN MM D CB CA C K J JA E H A' A 2-P through KA B 4-T counterbore Width across flats L S + Stroke Z + Stroke (mm) Port size Bore size (mm) GA H J JA A B A' C CA CB D E GB 20 25 32 29 32.5 35 19 23 27 16 20 24 12 15 19 26 32 40 42 50 62 20 25 31 22 25 31 9 10 11 27 22.5 25 14 18 22 12 15.5 19.5 8 10 12 M5 x 0.8 M5 x 0.8 Rc 1/8 Bore size (mm) NN T S Z K KA L MM P Q R Standard
(C) Load RBQ2508(C) P.910 to 0.05 to 3 RBQ3009(C) RJ RJ Allowable eccentric angle RBQ3213(C) RB D-X 881 Shock Absorber RJ Series Model Selection 1 Model Selection Graph The model selection graphs q to !
Fittings & Tubing Air Cylinders Rotary Actuators One-touch fitting [1(P), 3(R) port] Applicable tubing O.D.: 8, 5/16" [With External Pilot Specifications] 13.3 25 (Pitch) P = 10.5 25 13.3 16.2 16.2 17 36.7 34 34 B 2 B 2 PE B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 R 3 R 3 R 3 R 3 P 1 P 1 P 1 P 1 A 4 A 4 X A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 One-touch fitting (X, PE port) Applicable tubing O.D.: 6, 1/4"
63, 80 Aluminum (40) Iron (50, 63, 80) G, NPT 30, 45, 60, 75, 90 105, 120, 135 TURCK, P&F Aluminum body with reduced weight (40) Power Clamp Cylinder/CKZ2N Equivalent bore size [mm] Body material Port Arm opening angle Switch 50, 63, 80 Iron NPT, G 30, 45, 60, 75, 90 105, 120, 135 TURCK, P&F NAAMS Standards compliant Safety Instructions Be sure to read the Handling Precautions for SMC Products
L-type block (75) (50) W R P Q Port size Weight (kg) d K W Y AE (mm) (75) (50) W J W (mm) 1/2B (04) 3/4B (06) 1B (08) 1 1/4B (10) 1 1/2B (12) 2B (16) 2 1/2B (20) 3B (24) 22.2 27.7 34.5 43.9 49.1 61.1 77.1 90.0 47 47 47 50 50 50 50 50 70 70 70 85 85 85 105 105 9 9 9 9 9 9 9 9 62 62 62 65 65 65 65 65 3.5 3.5 3.5 6.2 6.2 6.1 11.9 11.9 Port size Weight (kg) E J P Q Port size Weight (kg) E 69
type 1 2 3 4 5 6 7 9 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 to 120 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Nil F N Rc (PT) G (PF) NPT Manual override Non-locking push type (Flush) Non-locking push type (Extended) Locking type (Tool required) Nil A B Other Electrical entry Light/Surge voltage suppressor G E T D DO Grommet Grommet terminal Conduit terminal DIN terminal
S) (mm) Dimensions PB S Model LVD2-T LVD3-T LVD4-T LVD5-T PA 13 26 A B 26 29.5 Dimensions (mm) A B C D E F G H J K L M N P Q T U Model LVD2-T LVD3-T LVD4-T LVD5-T 30 30 61 56 14.5 104 35 13 4 20 44 7 30 6 31.5 17 M5 to 0.8 35 35 79.5 62 17.5 136 42.5 17.5 6 22 50 7 37 6 36 21 M5 to 0.8 35 35 82 62 20 137 45 17.5 6 22 50 7 39 6 36 21 M5 to 0.8 45 45 105.5 76 25 169.5 65 17.5 8 32 64 7 52 6
(Same surface) 70 + 50 (n 2) n = 2, 4, 6, 8 75 + 50 (n 2) n = 2, 4, 6, 8 80 + 50 (n 2) n = 2, 4, 6, 8 85 + 50 (n 2) n = 2, 4, 6, 8 90 + 50 (n 2) n = 2, 4, 6, 8 55 + 50 (n 2) n = 2, 3, 4 With 1 pc. 70 75 80 85 90 10 With 2 pcs.
to 500 Up to 600 Up to 600 Up to 800 Up to 800 10 14 18 18 22 26 M14 x 1.5 10.5 M18 x 1.5 M18 x 1.5 12 14 15 11.5 17 M22 x 1.5 M26 x 1.5 With Rod Boot 151 to 200 l 151 to 200 h Bore size (mm) e f 1 to 50 25 25 25 25 25 25 51 to 100 37.5 37.5 37.5 37.5 37.5 37.5 101 to 150 50 50 50 50 50 50 201 to 300 100 100 100 100 100 100 301 to 400 125 125 125 125 125 125 401 to 500 150 150 150 150
to 500 Up to 600 Up to 600 Up to 800 Up to 800 10 14 18 18 22 26 M14 x 1.5 10.5 M18 x 1.5 M18 x 1.5 12 14 15 11.5 17 M22 x 1.5 M26 x 1.5 With Rod Boot 151 to 200 l 151 to 200 h Bore size (mm) e f 1 to 50 25 25 25 25 25 25 51 to 100 37.5 37.5 37.5 37.5 37.5 37.5 101 to 150 50 50 50 50 50 50 201 to 300 100 100 100 100 100 100 301 to 400 125 125 125 125 125 125 401 to 500 150 150 150 150
40 85 20 20KJlD 25 17 45 70 Single knuckle joint Accessory Data GKM20 10 50 100 Double knuckle joint JA-Floating joint 20 10 50 70 Rubber cushion Air cushion ( ): In the case of air cushion Calculation: (Example) C85N10-50, C85F10 Basic weight 49 (10)g Additional weight 3.2/10 mm of stroke Cylinder stroke 50 mm Mounting bracket 12g 49 + 3.2 x 50/10 = 65g 65 +12 = 77g Non-rotating rod: Double