IDX-OM-W029-B / Series IDU22E-23(-C,L,R,T,V) IDU22E-30(-C,L,M,R,T) IDU37E-23(-C,L,R,T,V) IDU37E-30(-C,L,M,R,T) IDU55E-23(-C,L,R,T,V) IDU55E-30(-C,L,M,R,T) IDU75E-23(-C,L,R,T,V) IDU75E-30(-C,L,M,R,T) URLhttps://www.smcworld.com/ English instruction manual can be downloaded from our URLhttps://www.smcworld.com/ SMC () * 1 ) JIS B8370 * 2 ) ISO4414 *1) ISO4414Pneumatic fluid power General

Weight (g) Model D-A90 6 30 D-A90V 6 30 D-A93 6 11 30 47 D-A93V 6 30 47 D-A96 8 41 D-A96V 8 41 0.5 m (Nil) 1 m (M) 3 m (L) 5 m (Z) Lead wire length Dimensions (mm) D-A90/D-A93/D-A96 D-A90V/D-A93V/D-A96V 2 2.8 4.5 2.7 Slotted set screw M2.5 x 4 L 4 24.5 (22) 22 2 6 Slotted set screw M2.5 x 4 L D-A90 without indicator light Indicator light 2.7 D-A90V without indicator light Indicator

l (mm) l 300 200 300 MGTL80 P = 0.5MPa m 200 MGTM80 100 P = 0.5MPa Load weight m(kg) Load weight m(kg) 40 50 100 Larger than 75st 50st 25st Larger than 50st 30 20 50 40 25, 50st 10 30 5 4 3 2 20 10 20 30 40 50 100 200 300 1 1 2 3 4 5 10 20 304050 100 200300400 Eccentric distance l (mm) 10 400 Eccentric distance l (mm) MGTL100 300 200 300 MGTM100 200 P = 0.5MPa 100 P = 0.5MPa Larger than

2 Port for Oil Dimensions (mm) (N.C.) 1in = 25.4mm Grommet: G Conduit: C Approx. 300 V D Approx. 280 D F Approx. 300 F Q Q Class H coil Broken line section C C G 1/2 R R E E A H A H B B 2-P Port size 2-P Port size 2-M, thread depth N 2-M, thread depth N L L K K DIN terminal: D Conduit terminal: T Cable 6.8 to 10 F S Q 27.5 (Q) D F 25 C R C (44) R R E G 1/2 E G 1/2 A H D (S) B B A H 2-P Port

2 Port for Steam Dimensions (mm) 1in = 25.4mm Grommet: G Conduit: C Q Approx. 300 F D Approx. 280 D Q F C G (PF) 1/2 C R R E E B A H 2-P Port size 2-P A B H 2-M Port size 2-M Thread depth N L L K K Conduit terminal: T F (Q) 34 25 U R C G (PF) 1/2 E B A H D 2-P Port size (S) 2-M L K N.C.

Applicable bore (mm) A D L MM N R W B C H d Applicable bore (mm) Part no.

Applicable bore (mm) A D L MM N R W B C H d Applicable bore (mm) Part no.

30 Total lifting range m Total lifting range m SUP=0.3MPa 20 20 SUP=0.3MPa SUP=0.2MPa SUP=0.2MPa 10 10 0 0 4 12 16 20 8 24 2 4 6 8 10 12 Discharge rate l/min Discharge rate l/min Selection from flow rate characteristic graphs (for PA3000) PA313 Air consumption 160 Required specification example: Find the pilot air pressure for a discharge rate of 4l/min and a total lifting range of 15m.

30 Total lifting range m Total lifting range m SUP=0.3MPa 20 20 SUP=0.3MPa SUP=0.2MPa SUP=0.2MPa 10 10 0 0 4 12 16 20 8 24 2 4 6 8 10 12 Discharge rate l/min Discharge rate l/min Selection from flow rate characteristic graphs (for PA3000) PA313 Air consumption 160 Required specification example: Find the pilot air pressure for a discharge rate of 4l/min and a total lifting range of 15m.

Note 3) Please consult with SMC when a blanking plate is needed. 14-5-13 13 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 14-5-14 14 Vacuum Regulator Series IRV1000/2000/3000 IRV1000 IRV2000 IRV3000 60 l/min (ANR) Note) 100 l/min (ANR) Note) 150 l/min (ANR) Note

condition r C = 0.90 based on condition r 2 2 Based on condition t, A and C Corrected air flow = 350 (0.75 x 1.00) = 467 l/min (ANR) 3 Based on condition t, B and C Corrected air flow = 1200 (0.95 x 0.90) = 1400 l/min (ANR) 3 Based on condition y; IDUS4E is selected as the model to process an air flow larger than 467 l/min (ANR) with a 50Hz power supply, according to data D-1.

Although a zener diode for surge protection is connected at the output side of a solid state auto switch, damage may still occur if the surge is applied repeatedly. When a load, such as a relay or solenoid which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8.

This controls the passage of air bled from the P o r p r e s s u r e p o r t o f t h e v a l v e . T h e m a i n v a l v e i s p n e u m a t i c a l l y o p e r a t e d b y t h i s a i r, switched by the solenoid.

condition r C = 0.90 based on condition r 2 2 Based on condition t, A and C Corrected air flow = 350 (0.75 x 1.00) = 467 l/min (ANR) 3 3 Based on condition t, B and C Corrected air flow = 1200 (0.95 x 0.90) = 1400 l/min (ANR) Based on condition y; IDUS4E is selected as the model to process an air flow larger than 467 l/min (ANR) with a 50Hz power supply, according to data D-1.

Fluid temperature [C] 382 A Digital Flow Switch PF2D Series For Deionized Water and Chemical Liquids How to Order Remote Type Monitor Unit PF2D3 A 0 M 0 Unit specification Nil M With unit switching function Fixed SI unit Note) Output specification 0 1 NPN open collector 2 outputs PNP open collector 2 outputs Note) Fixed units: Real-time flow rate: L/min Accumulated flow: L A Mounting Panel

+ + (Light/surge voltage suppressor) Approx. 300 (Lead wire length) L1 L2 6.5 Manual override 7 2-4.5 (For mounting) 56.1 [58.3] 34 (DIN 35.2) P R P R 17 6.5 30 16 15 A A A A 8 1/8 (P, R port) 2.5 (Pitch) P=16 18.5 (2.3) M5 x 0.8 (A port) (Station n) (Station 1) 15 3 3 14.5 L4 8 8 M3 x 0.5 (Bracket mounting screw) L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (W0

How to order L A T H 7 1 Cable length 1 1m ii. Dimensions iii. Wiring diagram Insulation color Terminal No. Function White Shield Black (2) Communication cable (between the branch connector and controller) i. How to order L E C C G 1 L Cable length(L) K 0.3m L 0.5m 1 1m ii. Dimensions 70 - (3) Cable between branches (between the branch connectors) i.

0.3 0.2 0.2 0.2 0.1 0.1 0.1 0 00 0 0 1000 2000 3000 4000 5000 0 1000 2000 3000 500 1000 1500 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] AR50(K)-B Rc1 AR60(K)-B Rc1 0.6 0.6 0.5 0.5 Outlet pressure [MPa] Outlet pressure [MPa] 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0 5000 10 0 0 0 5000 10 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 70 AR10-A Series AR20-B to AR60-B

min IDF11C is selected as the model to process an air flow larger than 1400 l/min (ANR) with a 60Hz power supply, according to data D-2.

A A A A 20.9 (DIN 22.1) (DIN 6.7) 1/8 (P, R port) 3.5 5.5 (Pitch) P = 16 18 Built-in speed controller (Station 1) (Station n) Max. 13.5 47.5 (Light/surge voltage suppressor) 52.6 [59.6] + + + 37.2 A A 18.5 5.5 24 B B (Pitch) P = 16 23 M5 x 0.8 (A, B port) L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (W0) 85.4 77.9 52.6 [59.6] 66.6 M8 x 1 57.1 127 0.6 0.6 37.2 39.6