MHF2-16D1 Scale: 50% 4H9 +0.030 0 depth 3 60 4H9 +0.030 0 depth 3 2-M5 x 0.8 thread depth 12 Mounting thread 6 79.5 5 M5 x 0.8 2-M5 x 0.8 thread depth 5.5 50 94 Mounting thread Finger closing port 26 74 10.6 E 20 20 24 33 E 0 -0.1 1.2 2-4.3 through (mounting hole) 27 29 1.2 29 M5 x 0.8 2-7.5 +0.1 0 Close: 0 Finger opening port E-E Open: 321 58 4-M5 x 0.8 thread depth 5.5 8-M4 x 0.7 thread
V Relay, PLC Yes Grommet 24 V 3-wire (NPN) Diagnostic indication 2-color indication IC circuit 5 V, 12V 3-wire (PNP) 2-wire 12 V A96 A93 A90 A96V A93V A90V IC circuit 5 V 3-wire (NPN equivalent) Yes 100 V 12 V Grommet Relay, PLC 24 V 2-wire 100 V or less 5 V, 12 V IC circuit Solid state auto switches marked with are produced upon receipt of order.
0.3 MPa Graph (5) F 0.4 MPa Graph (6) m 0.5 MPa Graph (7) F 694 Cylinder with Lock Series MNB Selection Graph Graph (5) Graph (2) P P 100 80 63 100 CLJ2 50 40 80 m m 63 CLM2 32 50 40 CLG1 32 CL1 MLGC CNG MNB V V CNA Graph (6) Graph (3) P P CNS 100 80 CLS 63 100 50 40 CLQ 80 63 50 m m RLQ 32 40 MLU 32 !"
(Note12) The capacity is 60Hz even in the 50Hz area when option P is selected. (Note13) The weight will increase by 4kg when option C and P is selected.
Nil Rc V V V V V N*1 NPT V V V V V F*2 G V V V V V + 01 1/8 V 02 1/4 V V V 03 3/8 V V 04 1/2 V 06 3/4 V 10 1 V V r Port size + a Mounting Nil Without mounting option V V V V V B*3 With bracket V V V V V + Option t Nil Without auto drain V V V V V b Float type auto drain C*4 N.C.
Weights Unit: g D-M9NW(V) D-M9PW(V) D-M9BW(V) Auto switch part no.
pressure detection port Branch Dimensions ZL6mmm-m (Without supply valve or release valve) ZL6 Without valve Branch Vacuum (2/V) port1 2(V) 2(V) 2 x Rc1/2, G1/25, NPT1/2 (Recommended tightening torque: 28 to 30 Nm) 2(V) 1(P) With vacuum With pressure Branch Silencer exhaust EXH With vacuum pressure switch pressure detection port gauge EXH. port exhaust G 121 32 P Vacuum pressure detection
How to order MHM-25D-X7400A-ASSISTA(-P) 6 - 3-2.
(Example: If the Pressure switch with output impedance of 1k is connected to the A/D converter to detect the analog output of 5 V, the detected voltage by the A/D converter becomes 5(V) 1(M)/(1(k) + 1(M)) 4.995(V), and there is an error of approximate 0.005 V.) Output impedance R The pressure range in which the Pressure switch satisfies the specifications.
x 0.8 M4 x 0.7 13 4 11 16 15 8 21 4.5 11 66 + Stroke 27.5 93.5 + Stroke 10, 16, 20, 25 Mounting nut Rod end nut G1 G2 NN 2-P I NA D J N2 N1 MM A F S + Stroke F H ZZ + Stroke (mm) Bore size (mm) A D NN F G1 P G2 MM S I ZZ H J N1 N2 NA M5 x 0.8 16 15 4 8 15 6 M12 x 1 M4 x 0.7 65 18.5 101 28 11 20 16 10 M5 x 0.8 22 15 5 10 15 6 M14 x 1 M5 x 0.8 74 22 114 30 12 21 19.5 16 Rc 1/8 28.5 18 8 13
Real-time switch output Unit switching Hysteresis mode ON For Air YES OFF P-1 P-2 Display Real-time flow rate l/min Accumulated flow l Real-time flow rate "P" Window comparator mode H : Hysteresis CFM x 10-2 x CFM x 10-1 ft3 x 10-1 H H CFM = ft3/min ON High Flow Rate Type (For Air) NO OFF P-1 P-2 Display Real-time flow rate l/min Accumulated flow l, m3, m3 x 103 Real-time flow rate OUT1
Parts description of the magnet gripper MHM-25D-X7400A-DTP-(N/P) Hexagon socket head cap screw M6x23 Auto switch D-M9(N/P) Magnet gripper Adapter plate Hexagon socket head cap screw M4x35 Exhaust throttle valve with silencer ASN2-M5-X937 Positioning pin 3x6 3 port solenoid valve V114-5LU Hexagon socket head cap screw M4x12 ISO9409-1compliant Conversion cable Hexagon socket head cap screw
(3) JOG JOGInching JOG tab Inching tab Speed Travel distance +/button (a)JOG Speed +/-+(b) SpeedMoving +/-+ JOG -22No.JXC-OMT0001CN-C 3.8 View(V) Test Drive (1) No.
200 V 110 V 220 V 240 V 48 V 230 V 24 V 12 V (D, E, N, P) Note) VXD2130 AC VXD21 4 5 Model VXD22 6 7 VXD23 8 9 DC specification is not available.
9 Specifications p. 10 Flow Range p. 11 Analog Output p. 11 Pressure Loss p. 11 IN Side Straight Section and Accuracy p. 12 Internal Circuits and Wiring Examples p. 12 Construction: Parts in Contact with Fluid p. 13 Dimensions p. 13 3-Screen Display Digital Flow Monitor PFG300 Series How to Order p. 14 Specifications p. 15 Internal Circuits and Wiring Examples p. 16
6 M1L025-17B82076 C-7 P-6 M1L040-17B82078 C-9 P-8 4.7-10 Series ML1 Auto Switch Specifications Refer to p.5.3-2 for the details of auto switch.
Note 2) Value on option V, M (Non-leak, Vacuum). Port A Port P Pilot Pressure Port P (N.O.) Model Pressure (MPa) 0.25 to 0.7 VXA31 4 VXA32 4 Option Material No.
SQ Pilot Valve/Spacifications AXT511C-4 (V) AXT511C-1 (V) AXT511C-2 (V) AXT511C-3 (V) AXT511C-4 (V) 24V DC 12V DC AXT511C-1 (V) 100V AC 50/60 Hz 200V AC 50/60 Hz 0.049/0.043 0.024/0.021 0.031/0.02 0.015/0.01 Part No.
v 25A CG1 v v MBlR V CG3 v v v v v v 10v 20JMB v v XAl MB MB v v v v v v v XB5 v v v v v XB6 MB1 v v v v v XB13 CA2 v v XC3 v XC4 CS1 v v v v v XC5 CS2 v XC6 Note 8) Note 8) v XC7 v v v XC8 v v v XC9 v v XC10 Note 4) Note 4) v v v v v XC11 v v v v v XC12 v v XC14 Note 3) v v v v v XC22 XC26 v v XC27 v v v v XC29 XC30 v v XC35 v XC65 XC68 XC88 XC89 XC91 Dv v v
Unit switching Real-time switch output ( ) ZSE ISE For Air Hysteresis mode Display Real-time flow rate l/min Accumulated flow l ON PSE YES CFM x 102, CFM x 101 ft3 x 101 OFF P-1 P-2 High flow rate Z I SE3 CFM = ft3/min P Window comparator mode H: Hysteresis High Flow Rate Type (For Air) PS H H Display Real-time flow rate l/min Accumulated flow l, m3, m3 x 103 ON Z I SE1 2 NO OFF P-1 P-