, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 25 3000 32 3000 40 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 5000 63 Note 1) Long stroke type (XB11) applies to the strokes exceeding 2000 mm.

, 200 M5 x 0.8 12-CY3B10 10 500 50, 100, 150, 200, 250, 300 15 1000 12-CY3B15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 12-CY3B20 20 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Rc1/8 NPT1/8 G1/8 25 12-CY3B25 (Both sides) Non-lube 32 12-CY3B32 1300 Rc1/4 NPT1/4 G1/4 12-CY3B40 40 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 12-CY3B50 50 12-CY3B63

Standard Stroke Bore size (mm) Standard stroke (mm) Maximum available stroke (mm) Made to Order: Individual Specifications (For details, refer to pages 1538 and 1539.) 6 10 300 500 50, 100, 150, 200 50, 100, 150, 200, 250, 300 50, 100, 150, 200, 250, 300, 350 400, 450, 500 Symbol Specifications -X116 -X168 -X322 -X431 Hydro specifications 15 750 Helical insert thread specifications 20 25

except waste water or agricultural water), Air, low vacuum Withstand pressure (MPa) 2.0 Valve specifications Coil specifications Ambient temperature (C) 10 to 50 Fluid temperature (C) 1 to 50 (No freezing) Environment Location without corrosive or explosive gases Valve leakage (cm3/min) 0 (with water pressure) 1(Air) VC Mounting orientation Unrestricted Vibration/Impact (m/s2) (4) VDW 30/150

to 0.7 Internal pilot Ambient and fluid temperature ( oC) Max. 50 Response time (ms) (at 0.5MPa) (1) 15 or less 10 Max. operating frequency (Hz) Non-locking push style, Push-locking slotted style Manual override Individual pilot exhaust, Common exhaust (pilot and main valve) Pilot exhaust Not required Lubrication Free Mounting position Impact/Vibration resistance (m/s2) (2) Base mounted 150

Characteristics Base resistance Acid resistance Weatherability Ozone resistance Abrasion resistance Waterproof Solvent resistance (Benzene, toluene) Oil resistance benzol Oil resistance gasoline Operating temperature range (C) Material Durometer HS (5) NBR 0 to 120 X 50 X X X 50 Silicon rubber 30 to 250 X X X X X Urethane rubber 0 to 60 60 X X X X X 60 Fluoro rubber 0 to 250 X 50 EPR 20 to 150

lo switches Bore sizel E--6,"'"-l IE ro.m I IE re '. 1 Port location on head cover stroke (l00ihs o Standard 50, 100, 150,200 50, 100, 150, 200, 300.400, 500,600 50, 100, 150. 200,300,400, 500,600,700,400 Doub e actino Sinole aclino sorinq relurn Sinale aclinq sprinq extend Se Caralog N301 ior slandard stroke Lenglhs on lypes otherrhan single rod 'lnrermedate shkes can b nanufacrured upon

SUP = 0.4 MPa SUP = 0.4 MPa 200 SUP = 0.3 MPa SUP = 0.3 MPa 100 SUP = 0.2 MPa SUP = 0.2 MPa 100 50 0 5 0 0 10 0 10 15 20 25 20 30 40 50 Discharge rate (L/min) Discharge rate (L/min) PAF3413 Air Consumption (3 Hz) PAF5413 Air Consumption (2 Hz) 200 Air consumption (L/min [ANR]) Air consumption (L/min [ANR]) 300 150 SUP = 0.5 MPa SUP = 0.5 MPa SUP = 0.4 MPa 200 SUP = 0.4 MPa 100 SUP = 0.3

LECP1 series is a programless controller capable of setting up an electric actuator operation without using a PC or teaching box.? Through the combination of parallel I/O inputs, 14 points of positioning are available.? The speed and acceleration of the positioning can be set by the switch for each operating direction.? A single signal sent to a dedicated terminal returns an actuator to

LECP1 series is a programless controller capable of setting up an electric actuator operation without using a PC or teaching box.  Through the combination of parallel I/O inputs, 14 points of positioning are available.  The speed and acceleration of the positioning can be set by the switch for each operating direction.  A single signal sent to a dedicated terminal returns an actuator to

Series LECP6 controller has two available modes for the setting software and teaching box.? In the easy mode, the operation can be started by only setting the speed, position, etc.? Using the normal mode allows a further detailed setup.??A few of the?main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator

Series LECP6 controller has two available modes for the setting software and teaching box.? In the easy mode, the operation can be started by only setting the speed, position, etc.? Using the normal mode allows a further detailed setup.??A few of the?main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER, STEP NPN, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR, .91491 lb, Stroke Model1002003004005006007008009001000Manufacturable stroke range [mm]LEFS40??????????200 to 1000

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER, SLIDE NPN, ACTUATOR, ELECTRIC ACTUATOR, IC, 25MM LE ELECTRIC ACTUATOR, 1.44953 lb, ModelBearingStroke (mm)Work load (kg)Speed (mm/s)Positioning repeatability (mm)Controller seriesReference pageLEL25MSliding bearingUp to 10003Up to 500?0.1Series LECP6Series LECP1Page 1

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER, BASIC NPN, ACTUATOR, ELECTRIC ACTUATOR, CC, 8MM LE ELECTRIC ACTUATOR, 1.44953 lb, ModelStroke [mm]Product weight [lb]BasicLEPY6250.5

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER, BASIC NPN, ACTUATOR, ELECTRIC ACTUATOR, CC, 8MM LE ELECTRIC ACTUATOR, 1.44953 lb, ModelStroke [mm]Product weight [lb]BasicLEPY6250.5

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER STEP NPN, ACTUATOR, ELECTRIC ACTUATOR, DC, 8MM LE ELECTRIC ACTUATOR, 1.98416 lb, ModelStrokePitchingYawingRolling[mm][N m]LESH850111112

LECP1 series is a programless controller capable of setting up an electric actuator operation without using a PC or teaching box.? Through the combination of parallel I/O inputs, 14 points of positioning are available.? The speed and acceleration of the positioning can be set by the switch for each operating direction.? A single signal sent to a dedicated terminal returns an actuator to

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER, STEP NPN, ACTUATOR, ELECTRIC ACTUATOR, IC, 25MM LE ELECTRIC ACTUATOR, .91491 lb, ModelActuator specificationsElectric specificationsLock unit specificationsStroke [mm] Note 1)Work load [kg] Note 2)Speed [mm/s] Note 2)Max. acceleration/deceleration [mm/s2]Positioning repeatability [mm]Lead

/s2] Note 6)Actuation typeGuide typeOperating temp. rangeOperating humidity range [%RH]Motor sizeMotor output [W]Motor typeEncoderRated voltage [V]Power consumption [W] Note 7)Standby power consumption when operating [W] Note 8)Momentary max. power consumption [W] Note 9)Controller weightType Note 10)Holding force lbf [N]Power consumption [W] Note 11)HorizontalVerticalLEY25A30, 50, 100, 150