SMC Corporation of America
Elite Part Number Search
Search Results "NCY2S32H-2000"

This serial interface is compatible with series SV1000/2000/3000, VQC1000/2000/4000, S0700 and the new SY series valves.

This serial interface is compatible with series SV1000/2000/3000, VQC1000/2000/4000, S0700 and the new SY series valves.

This serial interface is compatible with series SV1000/2000/3000, VQC1000/2000/4000, S0700 and the new SY series valves.

Delivery Pressure: J [10 to 1500 psig (0.07 to 10.3 MPa)], Relieving: 1 (Self-relieving, Standard), Material: C (300 SS Series), Ports: 4P (4 Ports), Connections: 4 (NPT 1/4 Inch), Gauge Port, Inlet: 20 [2000 psig (14 MPa)], Gauge Port, Outlet: 20 [2000 psig (14 MPa)], Pressure Gauge Unit: psig/bar (or None in Case of no Gauge), Main Valve Seat Material: Vespel®, Standard, O-ring Material

Delivery Pressure: J [10 to 1500 psig (0.07 to 10.3 MPa)], Relieving: 1 (Self-relieving, Standard), Material: C (300 SS Series), Ports: 4P (4 Ports), Connections: 4 (NPT 1/4 Inch), Gauge Port, Inlet: 20 [2000 psig (14 MPa)], Gauge Port, Outlet: 20 [2000 psig (14 MPa)], Pressure Gauge Unit: psig/bar (or None in Case of no Gauge), Main Valve Seat Material: PK (PEEK), O-ring Material: VitonÂ

Serial interface unit EX500 is capable of controlling up to 64 solenoids, and is compatible with SV1000/2000/3000/4000, VQC1000/2000/4000 valves. The EX500 makes it possible to connect up to 4 valve manifolds with up to 16 solenoids each.

Serial interface unit EX500 is capable of controlling up to 64 solenoids, and is compatible with SV1000/2000/3000/4000, VQC1000/2000/4000 valves. The EX500 makes it possible to connect up to 4 valve manifolds with up to 16 solenoids each.

Serial interface unit EX500 is capable of controlling up to 64 solenoids, and is compatible with SV1000/2000/3000/4000, VQC1000/2000/4000 valves. The EX500 makes it possible to connect up to 4 valve manifolds with up to 16 solenoids each.

Serial interface unit EX500 is capable of controlling up to 64 solenoids, and is compatible with SV1000/2000/3000/4000, VQC1000/2000/4000 valves. The EX500 makes it possible to connect up to 4 valve manifolds with up to 16 solenoids each.

This serial interface is compatible with series SV1000/2000/3000, VQC1000/2000/4000, S0700 and the new SY series valves.

EX260 compact serial interface unit is applicable to the SY3000/5000, SV1000/2000/3000, VQC1000/2000/4000 and S0700 series valves. The EX260 module is an output only SI unit that can be connected to any manifold designed for the EX250 series. Available protocols are PROFIBUS DP, DeviceNet and EtherCAT., SI UNIT, VALVE, EX300 SERIAL INTERFACE UNIT, 22, EX300, .44092 lb

Serial interface unit EX500 is capable of controlling up to 64 solenoids, and is compatible with SV1000/2000/3000/4000, VQC1000/2000/4000 valves. The EX500 makes it possible to connect up to 4 valve manifolds with up to 16 solenoids each.

CE2 ML2B Graph (1) Graph (2) RSA50, 63, 80 Bore size 50, 63, 80/ = 0 Bore size 50, 63, 80/ = 0.1 C J G5-S 1.0 1300 1300 RSH80 RSA80 RSH63 RSA63 RSH50 RSH50 RSA50 80 0.9 Operating pressure P [MPa] 1200 1200 CV 0.8 1100 1100 0.7 MVGQ 1000 1000 0.6 900 900 0.5 CC 63 80 Load weight m [kg] Load weight m [kg] 800 800 0.4 50 0.3 RB 700 700 0.2 600 600 J 0.1 63 500 500 50 1000 2000 3000 4000 5000

(Value in the initial state) Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz. Test was performed to axis and right angle directions of the main valve when pilot signal is ON and OFF.

Flow Rate Characteristics Flow Rate Characteristics VBAT05A 2 1.6 0.1 ARJ 1.4 Outlet pressure (MPa) Outlet pressure (MPa) P1 = 1.0 MPa 1.2 P1 = 0.8 MPa Max. pulsation range (MPa) AR425 to 935 0.08 P1 = 0.75 MPa P1 = 0.7 MPa 1 P1 = 0.6 MPa P1 = 0.5 MPa P1 = 0.5 MPa 1 0.8 P1 = 0.4 MPa 0.06 ARX P1 = 0.3 MPa P1 = P2 0.6 P1 = P2 AMR 0.04 0.4 0.2 ARM 0.02 VBAT05A 0 500 1000 1500 2000 2500 3000

(Valve in the initial stage) Vibration resistance: No malfunction from test with 45 to 2000 Hz one sweep, to axis and right angle direction of main valve, each one time when pilot signal ON and OFF .

(Values at the initial period) Vibration resistance: No malfunction from test with 45 to 2000 Hz one sweep, to axis and right angle direction of main valve, each one time when pilot signal ON and OFF.

stroke (mm) Maximum available stroke (mm) 300 50, 100, 150, 200 6 500 50, 100, 150, 200, 250, 300 10 15 20 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 1000 1500 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 25 3000 32 3000 40 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 5000 63 Note 1) Long stroke type (XB11) applies to the strokes exceeding 2000

Thermo-chiller/ Rack Mount Type HRR Series How to Order Option U Air-cooled Refrigeration HRR A 20 012 (UL Standards) Cooling capacity Option 012 1000/1200 W (50/60 Hz) 018 1600/1800 W (50/60 Hz) 024 2000/2400 W (50/60 Hz) 030 2500/3000 W (50/60 Hz) Nil None DM With electric conductivity control function, Applicable to DI water piping M Applicable to DI water piping T High-pressure pump mounted