Series S070 is a super compact direct acting 2/3 port solenoid valve that meets the miniaturization needs of analyzers and semiconductor manufacturing equipment. S070 is extremely lightweight (5g for valve single unit type) and operation noise is 38dB(A) or less. It is easy to increase or decrease the number of stations (stacking base). Valve width is 7mm. 3 port solenoid valve, direct operated

. -7No.EX-OMV0023-A Model Indication and How to Order EX260-SPL 1 Connector type, output specification 1 M12 connector, 32 outputs, PNP (negative common) / source 3 M12 connector, 16 outputs, PNP (negative common) / source Fieldbus PL POWERLINK -8No.EX-OMV0023-A Summary of Product elements No.

Symbol Data type Data length Bit [byte] Description (IO-Link standard) U8 8[1] UIntegerT Unsigned integer) U16 16[2] S16 IntegerT 16[2] Signed integer F32 Float32T 32[4] Floating point number 4: If the unit is not available when the unit is changed, a rejection response will be generated. In that case, change the range and unit to an available unit.

(After power OFFON, the parameter is enabled.) 32 - 5.3.7 Set the parameter of command pulse input form It is required to set the command input pulse form dependent on the upper unit pulse train when using the Position control mode (pulse input).

Since the possible number of stations differs depending on the connector type, refer to the valve station section on catalog pages 1-3-6, 1-3-7, and 1-3-32, and enter the number of stations in the mm section of the assembly part number.

Green Between case and AC line: 500 VDC, 50 Mor more GND 32 to 122F (0 to 50C) (No freezing) Ambient temperature F.G.

(no condensation) Withstand voltage 1000 VAC, 1 min. between terminals and case Insulation resistance 50 M min.

characters) Can be set to 16-32 characters. 0x0024(36) DeviceStatus R Refer to Section 3.3.2. 0x0025(37) DetailedDeviceStatus R Refer to Section 3.3.3. 3.3.1.

terminology 11 Electrical Connection 14 Wiring 14 Internal circuit and wiring example 15 Easy Setting 16 Measurement mode 16 Function Setting 19 Function selection mode 19 Default setting 19 F0 Unit selection function 21 F1 OUT1 22 F2 OUT2 24 F3 Response time 26 F4 Auto-preset 27 F6 Fine adjustment of display value 29 F11 Display resolution 30 F80 Power saving mode 31 F81 Security code 32

11 Mounting and Installation 14 Installation 14 Piping 15 Wiring 17 Outline of Settings [Measurement mode] 20 Pressure Setting 20 3-Step Setting Mode 21 Simple Setting Mode 23 Function Selection Mode 25 Function selection mode 25 Default setting 25 F 0 Display units, switch output specifications and diagnostic information selection function 27 F 1 Setting of OUT1 29 F 2 Setting of OUT2 32

[F 0] Units selection function Page 32 Units specification Pressure range Default setting ISE20C(H) MPa "Nil" or M ZSE20C(F) kPa ISE20C(H) P psi ZSE20C(F) [F 1] Setting of OUT1 Page 33 Item Explanation Default setting Output mode Either hysteresis mode, window comparator mode, error output or output off can be selected.

M5 01 N01 C4H C6H N7H C4L C6L N7L Port size M5 x 0.8 R1/8 NPT1/8 4 mm One-touch fitting Straight type 6 mm 1/4 inch 5/32 inch 4 mm One-touch fitting Elbow type 6 mm 1/4 inch 5/32 inch Pressure-sensing part Silicon Materials in fluid contact Piping port (Common) PBT, CB156, heat resistant PPS, O-ring: HNBR C3604 (Electroless nickel plating), SUS304, NBR part POM, SUS304, NBR, C3604 Piping

terminology 11 Mounting and Installation 14 Installation 14 Wiring 15 Wiring 15 Internal circuit and wiring example 16 Easy Setting 17 Measurement mode 17 Function Setting 20 Function selection mode 20 Default setting 20 F0 Unit selection function 22 F1 OUT1 23 F2 OUT2 25 F3 Response time 27 F4 Auto-preset 28 F6 Fine adjustment of display value 30 F11 Display resolution 31 F80 Power saving mode 32

(no condensation) Environment Withstand voltage 1000 VAC, 1 min. between terminals and case Insulation resistance 50 M min.

Refer to the list of switch output modes (page 31) and the flow setting chart (page 32). : When using a model without OUT2 (switch output), this setting is not available and [---] will be displayed. : Setting of OUT2 Press the or button in function selection mode to display [F 2]. [F2] and [oU2] are displayed in turn. : If OUT2 is not available, [---] will be displayed.

When window comparator mode is selected: Refer to page 32. When accumulated output mode is selected: Refer to page 33. When accumulated pulse output mode is selected: Refer to page 35. -30No.PF-OMP0002-H a. When hysteresis mode is selected Set value [P_1] or [n_1] and [the current set value] are displayed in turn. Press the or button to change the value. Press the button to set.

Cross-reference for troubleshooting 32 Error indication 34 Specification 35 Specifications 35 Characteristics data 37 Dimensions 38 Made to Order 40 -1No.PF-OMO0008-C Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.

Other functions Function selection mode (Refer to page 20) (Refer to page 32) -18No.PF-OMG0010-H List of outputs Find the diagram of the output required in the table below. Perform settings following the Set value column on the right.

setting 19 List of outputs 20 Initialize mode 21 Default settings 21 Setting procedure of Initialize mode 22 Function selection mode 26 Default settings 26 F_1 Input procedure of the Set value of instantaneous output 27 F_2 Input procedure of the Set value of accumulated output 28 F_3 Copy function 30 Other functions 31 Channel scan function 31 Peak/Bottom value display 31 Key-lock function 32

No.1 No.2 No.3 No.4 No.5 No.6 1 2 4 8 16 32 0 0 0 0 0 0 0 1 1 0 0 0 0 0 MAC ID 2 0 1 0 0 0 0 62 0 1 1 1 1 1 63 1 1 1 1 1 1 Communication speed setting (switches No. 7 to 8) Set the DeviceNetTM communication speed with a binary code of 125 kbps or 250 kbps or 500 kbps.