Bit line Bit Details 7 6 5 4 3 2 1 0 Time base Multiplier Bit 0 to 5: Multiplier (0 to 1) Bit 6 to 7: time base (00, 01, 10) Calculation condition Time base Time base value Calculation Cycle time 00 0.1 ms Multiplier x Time base 0.4 ms to 6.3 ms 01 0.4 ms 6.4 ms + multiplier x Time base 6.4 ms to 31.6 ms 10 1.6 ms 32.0 ms + multiplier x Time base 32.0 ms to 132.8 ms -78No.EX-OMZ0024 Data
(Default) Spare (SW2-2) Rotary axis setting switch (SW1) Description Display 0 Axis No.1 01 1 Axis No.2 02 2 Axis No.3 03 3 Axis No.4 04 4 Axis No.5 05 5 Axis No.6 06 6 Axis No.7 07 Down 7 Axis No.8 08 (Be sure to set to the 8 Axis No.9 09 "Down" position.) 9 Axis No.10 10 A Axis No.11 11 B Axis No.12 12 C Axis No.13 13 D Axis No.14 14 E Axis No.15 15 F Axis No.16 16 -12- 5.
Colour on the feed holes Cable colour Signal Cable O.D. 4.0 to 8.0 mm Electric wire cross section (Twist line) AWG26 to 22 YE=Yellow or OGWH=Orange/ White 1 Orange/ White TD+ WH=White or GNWH=Green/ White 2 Green/ White RD+ 3 Orange OG=Orange TD4 Green BU=Blue or GN=Green RD-40No.EX-OMP0013-E (3) Cable with communication connector Part number: EX9-AC 01 0EN-PSRJ Cable length (L) 01 1000 [
Piping: 41 (Base Mounted Common SUP Common EXH), Stations: 3 Stations, A B Port Size: 01 (Rc1/8)
Piping: Base Mounted Common SUP Common EXH, Stations: 3 Stations, A B Port Size: Rc1/8
20 2BFlange 30 3BFlange 40 4BFlange 20 2BFlange 30 3BFlange 40 4BFlange Shape Piping support style Standing style 60 6BFlange How to Select Max.
P . 14-20-57 14-20-42 2 Odor Removal Filter Series AMF How to Order AMF150 to AMF850 AMF 250 03 R B Option R IN-OUT reversal direction Body size Bracket Accessory (Option) 150 Standard 1 8 250 Standard 1 4 350 Standard 3 8 450 Standard 1 2 550 Standard 3 4 650 850 B 1 4 B 3 8 04 B 1 2 06 B Nil Nil B Piping port (B dimension) 1 Standard 11 2 Standard 01 B 1 8 02 03 Thread type Nil Rc F G N
Example) AWM30-03BE-1N AWD 30 03 BE q w e r t Body size Description Symbol 30 40 20 Nil N Note 1) F Note 2) Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + H Mounting Without mounting option With bracket With set nut a Nil B Note 4) + Without auto drain Float type auto drain (N.C.)
/O.D. mm Symbol Symbol Symbol 01 02 03 04 N01 N02 N03 N04 07 09 11 13 06 08 10 12 07 09 11 13 6 8 10 12 1/4" 5/16" 3/8" 1/2" R, Rc1/8 R, Rc1/4 R, Rc3/8 R, Rc1/2 NPT1/8 NPT1/4 NPT3/8 NPT1/2 50 60 65 80 85 110 5/8 6/9 6.5/10 8/12 8.5/12.5 11/16 Metric size The figures in ( ) indicate the internal diameter of the applicable hose.
Model VQZ100 VQZ200 VQZ300 AN110-01 AN110-01 AN200-02 AN200-02 AN110-01 Refer to page 4-14-3 for silencer for single valve unit. 4-14-17 18 Series VQZ Option Body Ported External Pilot Specifications Inch-size One-touch Fittings and Option Threads External pilot specifications are used when the operating pressure is below the minimum operating pressure 0.1 to 0.15 MPa or when valve is used
X17 P.69 Port size X26 P.70 Symbol Size 2C Applicable body size Accessory Option 3 4C 8C 11C 22C Symbol Nil Description Symbol Nil Description 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 B Bracket 2 Rubber material: Fluororubber For medium air pressure (1.6 MPa) Drain guide 1/4 female threaded 4 F H J R S U T V 2 Bracket is included, (but not assembled).
AXT100-20-2-05 AXT100-20-2-06 AXT100-20-2-01 AXT100-20-2-02 AXT100-20-2-03 AXT100-20-2-04 Valve Mounting VS After confirming the gasket is correctly placed under the valve, tighten the mounting screws with the appropriate torque listed below.
Option: Pressure gauge G15-10-01 How to Order NARM2000-4A2-N01G G15 P10 01 Symbol Units Nil MPa P PSI Common IN Individual IN IN M5 x 0.8 .39 (10) Max. pressure indication 10 150PSI (1.0MPa) .59 (15) IN OUT OUT *Pressure gauge for 30psig (0.2MPa) is not available.
Port size Body size Thread size Thread type Symbol N F Rc NPT G 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 An interface part is required if a spacer or spacer with bracket shown in the table below is attached to a modular FRL.
Port size Body size Thread size Port thread Symbol N F Rc NPT G 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 An interface part is required if a spacer or spacer with bracket shown in the table below is attached to a modular FRL.
No.EX##-OMY0006CN SI / / EX245-FPS1 EX245-FPS2 EX245-FPS3 / / EX245-DX1 / / EX245-DY1 EX245-FPS1/2/3 Firmware version (FW) : 2.1.X(X 0 ) Hardware version (HW) : 03 FW : FW : watch dog : PROFINET FW 2. 1.
size 01 B 1 8 B 1 4 B 3 8 04 B 1 2 06 B AFF 1 Standard 11 2 Standard Nil Rc Thread type 02 03 JIS Symbol AME AM F G N NPT P . 14-20-57 3 4 1B Misc. 10 14 1 B 1 2 20 2B Caution Note) Refer to How to Order Bowl Assembly on page 14-20-59.
AW30: G43-10-01-X3 or AW40: G43-10-02-X3 is included.
Example) 10-ARP30K-03BG-1RY Clean room compliant, copperfree, fluorine-free, silicone-free Clean room compliant Symbol Description 20 30 40 Body size 20 30 40 Body size Nil K Without backflow function With backflow function With backflow function + Nil N F Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) H a Without mounting option With bracket With set nut (For
Example) 10-ARP30K-03BG-1RY Clean room compliant, copperfree, fluorine-free, silicone-free Clean room compliant Symbol Description 20 30 40 Body size 20 30 40 Body size Nil K Without backflow function With backflow function With backflow function + Nil N F Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) H a Without mounting option With bracket With set nut (For