Circulating fluid return port When heating the circulating fluid, the high-pressure, high-temperature refrigerant gas is bypassed into the evaporator by expansion valve B to heat the circulating fluid. The combination of the precise control of expansion valve A for cooling and expansion valve B for heating allows for high temperature stability.
) 12 16 20 25 (mm) C1 9 10 12 15 H1 M5 x 0.8 M6 x 1.0 L1 14 15.5 18.5 22.5 X 10.5 12 14 17.5 M8 x 1.25 M10 x 1.25 Standard Bore size (mm) Stroke range (mm) A 25.5 25.5 29 32.5 (mm) Without auto switch With auto switch C D E F H I K L M N OA OB Q RA RB T B 22 22 24.5 27.5 A 30.5 30.5 39 42.5 B 27 27 34.5 37.5 12 16 20 25 5 to 30 5 to 30 5 to 50 5 to 50 6 8 7 12 6 8 10 12 25 29 36 40 5 5 5.5
Supply NC output NO output Exhaust of NC exhaust of NO Pilot tor NC Pilot for NO P A B R s z Y P A B R1 R2 z Y P A B EA EB PA PB 1 2 4 3 5 1 2 1 4 Table 7.2 Typical port identitications M O N O S T A B L E A N D B I S T A B L E Spring returned valves are monostable. They have a defined prefened position to which they automatically retum.
[mm] Model L A B n C D E Without lock With lock 11-LEJS63S-300656.5 696.5 306 370 6 1 200 180 11-LEJS63S-400756.5 796.5 406 470 8 2 400 80 11-LEJS63S-500856.5 896.5 506 570 8 2 400 180 11-LEJS63S-600956.5 996.5 606 670 10 3 600 80 11-LEJS63S-7001056.5 1096.5 706 770 10 3 600 180 11-LEJS63S-8001156.5 1196.5 806 870 12 4 800 80 11-LEJS63S-9001256.5 1296.5 906 970 12 4 800 180 11-LEJS63S-10001356.5
Mounted Type External Filot Type i trri--] .ZDI \ B .* ^N-_l ffiv J :FTT E \ I B N.O. N.C. I I nerer to pase@ I I I I I 4,5 Port Solenoid Pilot Operated Base Mounted Type(4 Port) Series:NVJ3OOO Port(Manifold only) ^-! + 4l/-\lF 4t/-t-\lF .
Mounted Type External Filot Type i trri--] .ZDI \ B .* ^N-_l ffiv J :FTT E \ I B N.O. N.C. I I nerer to pase@ I I I I I 4,5 Port Solenoid Pilot Operated Base Mounted Type(4 Port) Series:NVJ3OOO Port(Manifold only) ^-! + 4l/-\lF 4t/-t-\lF .
Mounted Type External Filot Type i trri--] .ZDI \ B .* ^N-_l ffiv J :FTT E \ I B N.O. N.C. I I nerer to pase@ I I I I I 4,5 Port Solenoid Pilot Operated Base Mounted Type(4 Port) Series:NVJ3OOO Port(Manifold only) ^-! + 4l/-\lF 4t/-t-\lF .
A part z1 m1 = 20 x 3 x 4 x 2.7 x 10-6 = 6.48 x 10-4 (kg) Weight calculation m1 = a x b x c x Relative density IZ1 Inertial moment around Z1 axis IZ1 = {m1 (a2 + b2) / 12} x 10-6 = {6.48 x 10-4 x (202 + 32)/12} x 10-6 = 2.21 x 10-8 (kg.m2) = 2.21 x 10-8 + 6.48 x 10-4 x 16.42 x 10-6 = 0.20 x 10-6 (kg.m2) IA Inertial moment around Z axis IA =IZ1 + m1r12 x 10-6 z f2 z2 B part r2 = 23.5(mm)
8370: JIS B 8361: JIS B 9960-1: -(1 : ) JIS B 8433: *2) 1. 2. 3. 1. 2. 3. 4
Number of pages has been increased from 12 to 16. WQ Edition B Safety Instructions Be sure to read the Handling Precautions for SMC Products (M-E03-3) and Operation Manual before use.
Auto switch a b d c Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Proper Mounting Position (mm) A B Bore size (mm) 63 80 100 10 13 17.5 14 18.5 23.5 Proper Mounting Position (mm) a b 14 18 17 c 20 24 23 d D-A9 type D-M9 type D-F9 W type 2 6 5 8 12 11 In order that
VDC) Brown LINE(+) Brown DC(+) Load Main circuit Main circuit (Analog output) 1k Black OUT 12 to 24VDC + 12 to 24VDC + Load Blue LINE() Blue DC() Load Install the load either on the LINE (+) or LINE (-) side.
VCA20-12-1A 41 52 30 40 4.5 6 VCA30-12-1A 48 56 36 44 5.5 7 VCA40-12-1A 50 62 38 50 5.5 7 2 mounting screws (for mounting brackets) are included in bracket part no. 17-2-12 7 Series VCA Direct Operated 2 Port Solenoid Valve For Air Dimensions Grommet: G Conduit: C Q F D Q F 300 280 D VC G1/2 C R C R L VDW IN E E VQ Manual override A B B A 2-P Port size 2-P Port size VX2 VX Manual override
A B c D E F G H J K M N 4.37 : 1 1 1 1 3 . 1 5 (80) 1 . 1 0 (2Al 1.22 (31)0.06 (1.5) ',.12 {3) 1.57 (40) 1.06 (271 1.42 (36) 1.26 (321 1.20 30.5' ).2t (6) Millimeters in Parentheses F O,F 7.05 lbs (3 2 kg) T T 90' '75 PSIG (5 Kgflcm2) A B c D E F G H J K ll N A B c D E F G H J K M N o 4.5() 114.31 3.30 83.8) 1.25 t31.8 1.20 (30.5) 0.89 '22.5) 0.06 (1.s) ). 12 (3) 1.57 (40) .42 (36) 1 2 6
A B c D E F G H J K M N 4.37 : 1 1 1 1 3 . 1 5 (80) 1 . 1 0 (2Al 1.22 (31)0.06 (1.5) ',.12 {3) 1.57 (40) 1.06 (271 1.42 (36) 1.26 (321 1.20 30.5' ).2t (6) Millimeters in Parentheses F O,F 7.05 lbs (3 2 kg) T T 90' '75 PSIG (5 Kgflcm2) A B c D E F G H J K ll N A B c D E F G H J K M N o 4.5() 114.31 3.30 83.8) 1.25 t31.8 1.20 (30.5) 0.89 '22.5) 0.06 (1.s) ). 12 (3) 1.57 (40) .42 (36) 1 2 6
1 1/4-12 2.00 2.375 1.88 6.88 800 (8") 1.75 1 1/4-12 2.00 2.375 1.88 7.00 Example: NCA1B500-0400-XC3BC (B = port, C = cushion) 11 AA 4-DD Series NCA1 Cylinder Large Bore Eye Bracket CB CD MR E R LR DD E R F M FL Dimensions Part No.
:GR-S-010(10g):GR-L-005(5g) 14 3-3. 2 (MHF2-8D2MHF2-12D20D) 1. 2. 8:12:R 1620:C ABC 3. (8:) (12 ) :GR-S-010(10g):GR-L-005(5g)GR-L-010(10g) 8 2 12 2.5 16 3 20 4 B C C 8 A 12 0.9 16 C MHF2-8D2 20 1.3 MHF2-12D* R MHF2-8D2 8 1.5 12 2 16 2.5 20 3 12 15 3-4. /1 MHF2-8DMHF2-8D1 1 16 2 17 3 18 4 19 5 20 NBR 6 21 NBR 7 8 A 9 B 10 C 11 12 13 14 15 MHF2-8D
200 95 12 11 135 115 210 190 82.5 19 23 142 50 75 150 115 MGG Bore (mm) Z Y X W WH W V U T S R Q O P MGC 20 25 32 40 50 140 80 30 30 23 36 40 86 12 26 12 21 M6 X 1 M5 X 0.8 MGF 153 80 37 30 25 44 47 98 13 31 12 21 M6 X 1 M5 X 0.8 161 82 37 25 28.5 50 53 112 16 38 12 21 M6 X 1 Rc(PT)1/8 CY1 188 92 44 20 33 60 63 132 20 47 12 25 M8 X 1.25 Rc(PT)1/8 241 104 55 20 40.5 70 73 162 25 58 14 26