SMC Corporation of America
Elite Part Number Search
Search Results "VV5FA3-30-101-00T"

side) 65 70 75 55 D-M9AV 55+30(n2)/2 n=4, 8, 12, 16 Other qty. 65+30(n2)/2 n=4, 8, 12, 16 70+30(n2)/2 n=4, 8, 12, 16 75+30(n2)/2 n=4, 8, 12, 16 65 95 2 switches (Different side) 60 75 80 85 2 switches (Same side) 90 100 105 110 D-A3 D-G39 D-K39 65+30(n2) n=2, 4, 6, 8 Other qty.

This system Your system Communication data TEMP PV 30 TEMP PV TEMP PV 30 TEMP SP 30 External communication 30 Discharge temp: OFFSET 1 31 Heat dissipation: 1 Circulating fluid temp. in your system: 30 Figure 8-6 When MODE3 is selected 8.4 Offset Function HRZD Series 8-16 HRX-OM-M005 Chapter 8 Appendix 8.5 BAND/READY Function Sets BAND to TEMP SP value, and notifies TEMP PV value reaches within

G) S T U V W WX Y Z PF3W704/504 PF3W720/520 PF3W740/540 PF3W711/511 24 22 32 40 50 4.5 5 1.5 70 50 30 60 45.6 40.6 15.2 24 14 35 26 18 13.6 2.7 depth 14 3/8 28 22 32 40 50 4.5 5 1.5 78 54 30 60 45.6 40.6 15.2 27 18 39 30 18 13.6 2.7 depth 12 3/8, 1/2 34 30 42 48 58 4.5 5 1.5 98 71 38 68 53.6 48.6 19.2 32 28 49 35 28 16.8 2.7 depth 12 1/2, 3/4 44 36 48 58 70 5.5 7 2.0 124 92 46 77 62.6 57.6

EVS1001-9-2H Gasket 1 AXT632-25-15 (M4 x 30, with washer, nickel plated) Hexagon bolt 2 EVS1001-9-1 Light cover 3 29.5 x 1.2 O-ring 4 OR-0500-130-H O-ring 5 30 Exploded View of Manifold Manifold block assembly D-side end plate assembly U-side end plate assembly Housing assembly and SI unit EX250 EX600 EX500 EX126 S kit q r e w t @0 i u y @2 !8 o @1 !0 !9 !

Check the angle of the is unavailable in excess of 30/+30 degrees on both ends of the actuator. feedback lever in Initial 21,22 Adjustment, and securely adjust the angle to 30/+30degrees or less. The angle of the feedback lever -The standard positioner stroke is is less than 10 degree or 30 degree or larger from 10 to 30 degrees. Use it within 10 to 30 degrees. 5 -Others.

Type Optical linear encoder (incremental) Resolution [ m] 30 1.25 30 1.25 30 1.25 5 1.25 Sensor Origin position signal None Provided None Provided None Provided Provided Pushing speed [mm/s] 6 Pushing operation Set value of force Note 1) Note 2) Note 3) 1 to 5 1 to 4.8 1 to 3.9 1 to 2 Positioning resolution [ m] 30 1.25 30 1.25 30 1.25 5 1.25 Positioning operation Positioning repeatability

This system Your system Communication data TEMP PV 30 TEMP PV TEMP PV 30 External communication 30 TEMP SP 30 Discharge temp: OFFSET 1 31 dissipation: Heat 1 Circulating fluid temp. in your system: 30 Figure 8-9 When MODE3 is selected HRZ Series 8.4 Offset Function 8-21 HRX-OM-I051 Chapter 8 Appendix 8.5 BAND/READY function Sets BAND to TEMP SP value, and notifies TEMP PV value reaches

24 33 5.5 12 3.5 29 Note) 1/81/4 1/43/8 1/43/8 AC25B-B 1/8 110.2 115.1 28 30 55.1 35 27.5 0 41 35 7 14 4 41 AC30B-B 1/8 110.2 115.1 30.7 30 55.1 35 29.4 3.5 41 35 7 14 4 41 AC40B-B 1/8 145.2 147.1 35.8 38.4 72.6 40 33.8 3.5 50 40 9 18 5 48 1/43/81/2 AC40B-06-B 1/8 155.2 149.1 35.8 38.4 77.6 40 33.8 3 50 40 9 18 5 48 3/4 AC50B-B 1/8 186.2 220.1 43 93.1 30 43.3 3.2 70 50 11 20 6 60 3

Vinyl chloride piping tube (30 A) ZS-40-U30 30 A Vinyl chloride piping tube 1 pc. 25 A Holding plate ZS-40-U25-A 1 pc., With two hexagon socket head cap screws of M5 x 80. 30 A Holding plate ZS-40-U30-A 1 pc., With two hexagon socket head cap screws of M5 x 65. : Accuracy may vary by 1 to 2%, if vinyl chloride piping tube is replaced. -13No.PF-OMM0005-N Summary of Product parts Body 1 DC(

Specifications LAT3-10 Stroke 10 mm, Resolution 30 m LAT3-20 Stroke 20 mm, Resolution 30 m Card Motor 8 options LAT3-30 Stroke 30 mm, Resolution 30 m (Refer to the table Product LAT3M-50 Stroke 50 mm, Resolution 5 m Number on the right) LAT3F-10 Stroke 10 mm, Resolution 1.25 m LAT3F-20 Stroke 20 mm, Resolution 1.25 m LAT3F-30 Stroke 30 mm, Resolution 1.25 m LAT3F-50 Stroke 50 mm, Resolution

30 HRLE090-m-20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) M5 R5.5-5 4 cores x 5.5 mm2 30 (4 cores x AWG10) Including grounding cable HRLE090-m-40 3-phase 380 to 415 VAC (50/60 Hz) 3-phase 460 to 480 VAC (60 Hz) M8 R5.5-8 20 An example of the cable specifications is when two kinds of vinyl insulated wires with a continuous allowable operating temperature of 70C at 600 V, are

Bonnet assembly/Part indication number (1) Temperature specifications Indicator Valve size 16 25 40 50 General use Without XLF16-30-1-2 XLF25-30-1-2 XLF40-30-1-2 XLF50-30-1-2 With XLF16A-30-1-2 XLF25A-30-1-2 XLF40A-30-1-2 XLF50A-30-1-2 High temperature Without XLF16-30-1H-2 XLF25-30-1H-2 XLF40-30-1H-2 XLF50-30-1H-2 With XLF16A-30-1H-2 XLF25A-30-1H-2 XLF40A-30-1H-2 XLF50A-30-1H-2 Temperature

The dog fitting cannot be attached to the knuckle joint, M6 without tap (rod end bracket symbol I or Y). 20 97 30 42.5 Part no.

MXP16-20 MXP16-30 0.08 0.12 0.06 MXP16-20 MXP16-30 MXP16-20 MXP16-30 MXP16-20 MXP16-30 MXP16-20 MXP16-30 0.10 Table displacement mm Table displacement mm Table displacement mm 0.06 0.04 0.08 0.04 0.06 0.04 0.02 0.02 0.02 0 0 0 50 200 250 Load N 150 100 50 200 250 Load N 150 100 100 400 500 Load N 300 200 3 Precision Air Slide Table Series MXP Table Accuracy Clean Series: Precision Air Slide

AC20C-D to AC40C-D 30 03 DE AC C D Symbol Description Body size 20 30 40 Rc Nil Thread type NPT N G F 1/8 1/4 3/8 Port size 01 02 03 3/4 1/2 04 06 Nil Without auto drain a Float type auto drain C N.C. (Normally closed) Drain port is closed when pressure is not supplied. D N.O. (Normally opened) Drain port is opened when pressure is not supplied.

Motor cable: Counter axis side Lock cable: Counter axis side Encoder cable: Axis side (30) L 37.4 LE-CSNA LE-CSNB I/O connector LE C SNA 37.2 52.4 Controller type I/O connector (LECSA) I/O connector (LECSB) SNA SNB 39 39 Regeneration option 6 Mounting hole LA LEC MR RB LEC (12) 144 12 (6) 15 Regeneration option type 032 Allowable regeneration power 30 W 12 Allowable regeneration power 100

Table (14) Model of switch spacer Size 30 50 63 80 100 Model of Switch spacer BMY3-016 The above models include 1 piece of switch spacer.

IDX-OM-W028-B Operation Manual PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDU22E-23(-C,L,R,T,V) IDU22E-30(-C,L,M,R,T) IDU37E-23(-C,L,R,T,V) IDU37E-30(-C,L,M,R,T) IDU55E-23(-C,L,R,T,V) IDU55E-30(-C,L,M,R,T) IDU75E-23(-C,L,R,T,V) IDU75E-30(-C,L,M,R,T) Please read this manual prior of using the air dryer. Keep the manual readily available for reference.