Model AMR3000 AMR4000 AMR5000 AMR6000 Model name 1 4 3 8 1 2 : E4-02 : E4-03 : E4-04 1 4 1 2 : E6-06 : E6-10 3 4 : E3-02 : E3-03 : E5-04 : E5-06 Adapter assembly (7) 3 8 3 4 1 AD33-X203 AD33-X202 AD33-X210 AD33-X201 Float type auto drain (AMR 100) (8) IS10-01 (0.4 MPa setting) Compact pressure switch 135510 135613 Elbow (R x Rc) (9) Note 5) in the gauge part number (e.g.
Request message to read (from master) 02 30 31 52 50 56 31 03 65 Request to read Address BCC data End code Identification code Start code Response message from the product 02 30 31 06 50 56 31 30 30 32 35 30 03 06 Address Start code BCC data Affirmation code End code Numerical data Identification code Code Symbol/Data ASCII code Start code STX 02H Address 01 30H 31H Required content R
Request message to read (from master) 02 30 31 52 50 56 31 03 65 Address BCC data End code Request to read Start code Identification code Response message from the product 02 30 31 06 50 56 31 30 30 32 35 30 03 06 Address BCC data End code Start code Numerical data Affirmation code Identification code Code Symbol/Data ASCII code Start code STX 02H Address 01 30H 31H Required content R
Symbol 0 1 2 Port size Port size Applicable model Symbol FQ1010 FQ1011 FQ1012 04 06 10 Rc1/2 Rc3/4 Rc1 Housing O-ring material Industrial Filters Replacement Procedure Actuators Modular F.R.L.
Auto Switch Mounting Bracket Part No. 32 40 50 63 80 100 Auto switch model Bore size (mm) Bore size (mm) 40 32 50 63 80 100 Foot (1) MNB-L06 MB-L03 MB-L04 MB-L05 MB-L08 MB-L10 D-A5/A6 D-J5/F59F Flange MNB-F03 MNB-F04 MNB-F05 MNB-F06 MB-F08 MB-F10 BT-03 BT-03 BT-05 BT-05 BT-06 BT-06 Single clevis MB-C08 MB-C10 MB-C03 MB-C04 MB-C05 MB-C06 D-A3/A44 D-G39/K39 BMB2 -032 BMB2 -040 BMB1 -050 BMB1
MPa) Sub-atmospheric (A): 100 mm Hg absolute to 10 psig (-88 kPa to 0.07 MPa) Code Range options 1) Specification Code Ports 2 ports 3 ports Standard (Cv: 0.07) Code Specification Standard Sub-atmospheric 2PW 3PW No code 01 No code A High flow (Cv: 0.15) HF 1) Only available with SL5201. 0.5 to 30 psig (0.0034 to 0.2 MPa) 1 to 60 psig (0.007 to 0.4 MPa) 1 to 100 psig (0.007 to 0.7 MPa) 02 06
1/4" 6 6, 8 1/4" 5/16" 3/8" Tubing O.D. 3/16" 1/4" 1/4" 5/16" 3/8" 3/8" Inch size Flow rate l/min (ANR) Controlled flow (Free flow) 500 600 700 1200 1300 175 295 350 75 {N R/min} Effective area (mm2) 7.6 9.1 10.7 18.3 19.8 2.7 4.5 1.1 5.3 Note) Flow rate values are measured at 0.5 MPa and 20C. 15-9-14 2 Dual Speed Controller with One-touch Fitting Series ASD How to Order ASD 3 30F 01 06
Note) 4 6 8 10 12 23 04 06 08 10 12 3.2 TMH-23J TMH-04J TMH-06J ASV Body size AS1001F AS2001F AS2051F AS3001F AS4001F AK TMH-06 TMH-08 ASS TMH-10 TMH-12 Applicable tubing Inch Size ASR Note) Mounting bracket is not available. This is an application example. Applicable tubing size ASF 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 01 03 05 07 09 11 13 Can be mounted on the panel.
Thread type Nil Rc F G N NPT T NPTF 04 1/2 06 3/4 10 1 SA VA JIS Symbol VM N.C. N.O. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Specifications VR Operating type Air operated type Type of actuation N.C./N.O.
For details, please contact SMC. 3-11-17 18 Manifold Specifications Standard Specifications ISO Size 1 ISO Size 2 ISO Size 1 Maniflod block size VSR/S8-6 VSR/S8-8 VSR/S8-6 Applicable solenoid valve 1 to 10 Number of stations 1/4, 3/8, 1/2, 3/4, 1 A, B port Port size 1/4, 3/8, 1/2, 3/4, 1 P , EA, PB port VV82-P-03/04/06 VV81-P-02/03/04 Individual SUP spacer VV82-R-03/04/06 VV81-R-02/03/04
SV100 ANA1 -C08 T0604 SV200 ANA1 -C10 T0806 200 CM2 32 400 MB 50 300 150 Stroke (mm) Stroke (mm) AS2201F -01-06 AS2200-01 AS3201F -02-08 AS3000-02 200 100 100 50 0 0 200 CM2 40 400 MB 63 150 300 Stroke (mm) Stroke (mm) AS2201F -02-06 AS2200-02 100 AS4000-03 200 50 100 0 0 Solenoid valve Silencer Tubing Speed controller Solenoid valve Silencer Tubing Speed controller 200 300 400 500 600 700
SV100 ANA1 -C08 T0604 SV200 ANA1 -C10 T0806 200 CM2 32 400 MB 50 300 150 Stroke (mm) Stroke (mm) AS2201F -01-06 AS2200-01 AS3201F -02-08 AS3000-02 200 100 100 50 0 0 200 CM2 40 400 MB 63 150 300 Stroke (mm) Stroke (mm) AS2201F -02-06 AS2200-02 100 AS4000-03 200 50 100 0 0 Solenoid valve Silencer Tubing Speed controller Solenoid valve Silencer Tubing Speed controller 200 300 400 500 600 700
Note) Fixed units: Real-time flow rate: l/min Accumulated flow: l Port size Applicable model Flow rate (l/min) Nil N M12 3 m lead wire with connector Without lead wire Symbol 100 40 4 16 03 04 06 10 3/8 1/2 3/4 1 PF2W704, PF2W720 PF2W720, PF2W740 PF2W740, PF2W711 PF2W711 Output specification 27 67 NPN open collector 2 outputs PNP open collector 2 outputs Specifications PF2W720 PF2W704
N L1 L2 L3 L4 L5 L6 P Q1 Q2 M KRM12-06-02-10 KRM12-06-02-6 99 10 6 6 89 47 1 4 17 19.5 33.5 23.5 33 13.5 8.5 13 19 10 125 6 108 10 55 73 106 104 KRM12-08-03-10 KRM12-08-03-6 3 8 8 19 139 11.5 22.5 37.5 26 36.5 10 15.5 20.5 14.7 86 126 119
-01-06 AS2200-01 100 50 0 ANA1 -C08 T0604 200 CM2 32 150 Stroke mm AS2201F -01-06 AS2200-01 100 50 0 200 CM2 40 150 Stroke mm AS2201F -02-06 AS2200-02 100 50 0 Solenoid valve Silencer Tubing Speed controller 200 300 400 500 600 700 800 900 1000 1100 1200 Speed at the end mm/s Applicable related components For details regarding different conditions, make determinations after using the P/A
PD07 *DI3 3(CN6-3) CN6-3 PD06 000Ah 0 0 CN6-3 CN6-3 PD08 *DI4 4(CN6-4) CN6-4 PD06 000Bh 0 0 CN6-4 CN6-4 6 33 6 PD09 *DO1 1(CN6-14) CN6-14 0002h 0 0 CN6-14 CN6-14 () 00 OFF 02 RD 03 ALM 04 INP 05 MBR 06 DB 07 TLC 08 WNG 09 BWNG 0A SA 0C ZSP 0F CDPS 23 CPO 24 ZP 25 POT 26 PUS 27 MEND 38 1 PT0 39 2 PT1 3A 3 PT2 3B 4 PT3 3C 5 PT4 3D 6 PT5 3E 7 PT6 3F 8 PT7 .
C 1. ##0016 ## 00 01 1 02 2 03 3 04 4 05 5 06 6 07 7 08 8 09 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 2. **No. 3.
Step Request data Response data Operation details 1 01 06 0412 000A 01 06 0412 000A Sets Step Data No. 1 Positioning time to 0.1 sec. 01 10 0410 0002 2 01 10 0410 0002 Sets Step Data No. 1 Target position to 10 mm. 04 0 2710 (4) Return to Origin Change the Card Motor controller (controller ID1) operation mode to serial operation, and send a Return to Origin instruction.