Blue DC() -26 Analog output type 1 to 5V (2.5% F .S.) Output impedance: 1k Bring the pressure back to atmospheric pressure and try using the zero out function. Residual pressure error Brown DC(+) Black OUT (Analog output) + 12 to 24VDC Load Blue DC() Supply pressure exceeds the maximum regulating pressure. -28 Analog output type 4 to 20mA (2.5% F .S.)
-23ST AS121F-U10/32-07T 13.5 12 18.3 23.1 1/4" 3.2 8.4 20 12.7 20 AS221F-01-04ST AS221F-N01-01ST 1/8" 8.4 20.4 27.5 4 9.3 12.7 5/32" 9.3 20.4 27.5 13.4 21 AS221F-01-06ST AS221F-N01-03ST 34.7 R1/8 12 14.2 7 1.5 31.6 13.5 6 11.6 21 13.4 34.7 AS221F-01-08ST AS221F-N01-05ST 16.5 NPT1/8 12.7 14.2 7 1.5 31.6 3/16" 13.2 24 31.1 18.5 25.3 32.4 8 15.2 23 23 AS221F-01-10ST AS221F-N01-07ST 15.3 17 1
~:;:--l' VAC Vacuum load lock chamber Digital pressure switch Digital Pressure Switch Series ZSE6/ISE6 (For vacuum) (For positive pressure) Model 1~SV(S % F ,S, ) ".
Accessory (Option) Part No. 134856 G15-10-01(Rc1/8)/G15-P10-N01(NPT1/8) Bracket Pressure gauge Note) Note) Pressure gauges (G15) for 0.2 MPa are not available. How to Order Port size (IN, OUT) 1/8 (Male thread), M5 x 0.8 (Female thread) 1/8 (Female thread) IN OUT 01 ARJ 3 10 01 BG Made to Order Refer to page 676 for details.
Output voltage (Rated pressure range) Linearity Output impedance Note 2) Voltage output 1% F .S. Approx. 1 k Analog output 2.4 to 20 mA 2.5% F.S. 4 to 20 mA 2.5% F.S. Output current (Rated pressure range) Linearity Note 3) 1% F .S.
(10G) in X, Y, Z directions for 2hrs. each (deenergized) 980m/s (100G) in X, Y, Z directions 3 times each (deenergized) In a temperature range of 0 to 50C, 2% F.S. or less of pressure measured at 25C Vibration resistance Impact resistance Temperature characteristics 01: R1/8, M5 x 0.8, T1: NPT1/8, M5 x 0.8, W1: Rc1/8 C4: With 4 One-touch fitting, C6: With 6 One-touch fitting, M5: M5 female
Series AS Speed Controller with One-touch Fitting Elbow Type/Universal Type How to Order 2 2 0 01 06 S AS 1F Hexagon lock nut Round lock nut J Nil Lock nut option Body size AS AS 1 2 3 4 M3, M5 standard 1/8, 1/4 standard 3/8 standard 1/2 standard Made to Order (Refer to page 490 for details.)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting)
Function: 3 (3 Position Closed Center), Piping: 4 (Base Mounted), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal w/Connector), Surge Suppressor: S (Surge Suppressor), Manual Override: None, Port Size: 01 (Base Mounted w/Sub-plate 1/8)
Body Size: 2 (1/8, 1/4), Type: 201, Port Size: 01 (R1/8, Rc1/8), One-touch Fitting: F (w/One-touch Fitting), Valve Side Applicable Tubing O.D.: 06 (ø6), Sealant: S (w/Sealant)
Body Size: 2 (1/8, 1/4), Type: 200, Port Size: 01 (R1/8, Rc1/8), One-touch Fitting: w/o One-touch Fitting, Valve Side Applicable Tubing O.D.: None, Sealant: S (w/Sealant)
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: 01 (Rc1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover]
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: 01 (Rc1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover]
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: 01 (Rc1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Z (w/o Lead Wire w/Connector)
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: 01 (Rc1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: N (None), Calibration Certificate: None, Connector: Z (w/o Lead Wire w/Connector)
Flow Rate Range: 25 [0.5 to 25 (12.5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: 01 (Rc1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Z (w/o Lead Wire w/Connector)
.: 04 (ø4), Residual Pressure Release Function: E (w/Residual Pressure), Thread Type: Rc, Size: 01 (1/8), Seal Method: S (w/Sealant)
.: 07 (ø1/4"), Residual Pressure Release Function: E (w/Residual Pressure), Thread Type: N (NPT), Size: 01 (1/8), Seal Method: S (w/Sealant)
.: 06 (ø6), Residual Pressure Release Function: E (w/Residual Pressure), Thread Type: Rc, Size: 01 (1/8), Seal Method: S (w/Sealant)