Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C6 (ø6), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: S (Bracket, w/Flow Adjustment Valve), Calibration Certificate: A (Calibration

Rated Vacuum Range: -101 to 0 kPa, Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Piping Specification: M5 (Female Thread, Connector Type: S (M12 Connector Type), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 Connector Type), Bracket: A4 [Bracket D for M12 Connector Type (ZS-46-A4)], Operation Manual: K (Operation Manual, Calibration Certificate)

Flow range (lpm): 5-500, 10-1000, 20-2000; Port sizes (Rc, NPT, G): 1/2 or 3/4 (flow range dependent); Rated pressure range: (MPa): 0 to 0.8; Output options: NPN/PNP, 1-5V, 4-20mA; Accuracy: ±3% F. S.; Repeatability: ±1% F. S.

Flow ranges (lpm): 0.2-10, 0.5-25, 1-50, 2-100; Port sizes: 1/8 or 1/4 (Rc, NPT, G); ø6 or ø8 one-touch fittings; Rated pressure range (MPa): -0.07 to 0.75; Output options: 1-5V or 4-20mA; Accuracy: ±3% F. S.; Repeatability: ±1% F. S.

Body sizes: 25, 32, 40; Maximum work load: 60 kg; Maximum speed: 1500 mm/s; Stroke range: 50 to 500mm in 50mm increments, 600-1200mm in 100mm increments; Positioning repeatability: ±0.01mm; Dynamic allowable moment: 8-61% improved vs. LEFS (size and axis dependent); Encoder resolution: 17-bit (S motors), 22-bit (T motors), 20-bit (V motors)

SMC's updated VXD series for oil (viscosity not exceed 50mm²/s) is a pilot operated, 2 port solenoid valve. FKM seal material and Class H coil insulation to suit the high fluid temperature application are standard. Available in brass and stainless steel.

The WRF100-X2818, X2808 can be selected from 2 clamping position, Centering (WRF100-X2814) and Side Positioning (WRF100-X2808).  Standardized T-type and S-type arms allows the selection to meet certain specifications or applications. Stable clamping force; Operating pressure: 0.5 MPa; Optional spatter protective cover; Standardized T/S type arms

Series CJ5-S is a small bore stainless steel cylinder, designed for use in environments with water spray (such as food processing machines). A special scraper (standard) prevents water from entering the cylinder. Non-toxic additives allow confident use in equipment for food, beverage and medical products, etc. The CJ5-S series can be disassembled for replacement of seals.

ISE20B-L-S incorporates IO-Link version 1.1 and COM2 speed. 16-bit process data include 2 output bits for set points, a diagnosis bit, and 13 bits for the measured pressure value. The 3-screen, 3-color display shows the instantaneous reading in red or green, and the setting label and its numerical value in orange. ISE20B-L is UL/CSA, CE and RoHS compliant, with an IP65 enclosure rating.

ISE20B-L-S incorporates IO-Link version 1.1 and COM2 speed. 16-bit process data include 2 output bits for set points, a diagnosis bit, and 13 bits for the measured pressure value. The 3-screen, 3-color display shows the instantaneous reading in red or green, and the setting label and its numerical value in orange. ISE20B-L is UL/CSA, CE and RoHS compliant, with an IP65 enclosure rating.

ZSE20B(F)-L-S incorporates IO-Link version 1.1 and COM2 speed. 16-bit process data include 2 output bits for set points, a diagnosis bit, and 13 bits for the measured pressure value. The 3-screen, 3-color display shows the instantaneous reading in red or green, and the setting label and its numerical value in orange.

ZSE20B(F)-L-S incorporates IO-Link version 1.1 and COM2 speed. 16-bit process data include 2 output bits for set points, a diagnosis bit, and 13 bits for the measured pressure value. The 3-screen, 3-color display shows the instantaneous reading in red or green, and the setting label and its numerical value in orange.

Manifold with Stainless Steel Plate: S, Model: 51S (EX260), SI Unit: 0 (without SI Unit), Wiring Type: S (All Single Wiring), Valve Stations: 24 (24 Stations, All Single Wiring), Port Size: N7 [4(A)/2(B) Port: ø1/4"; 1(P)/3(EB), 5(EA) Port: ø3/8"], Thread Type: One-touch: None; Thread Piping: Rc, Option: P (Trim Plate)

Stations: 4 Stations, Port Size: N7 (ø1/4" One-touch Fitting), S Kit: SDA (EtherCAT - 32 Outputs - Connector M12), SI Unit Polarity: N (Negative Common), Option 1: D0 (DIN Rail Mounting, w/o DIN Rail), DIN Rail Length: Standard (or None if w/o DIN Rail), Option 2: S (Built-in Silencer, Direct Exhaust)

Stations: 5 Stations, Port Size: N7 (ø1/4" One-touch Fitting), S Kit: SKA (IO-Link - 32 Outputs - Connector M12), SI Unit Polarity: N (Negative Common), Option 1: None, DIN Rail Length: Standard (or None if w/o DIN Rail), Option 2: S (Built-in Silencer, Direct Exhaust)

Stations: 12 Stations, Port Size: N3 (5/32" One-touch Fitting), Kit Name: F (D-sub Connector 25 Pin), Electrical Entry: S (Side), Cable Length: 0 (w/o Cable 25 Pin), Option 1: None, Option 2: None, Option 3: None, Option 4: None, Option 5: S (Built-in Silencer, Direct Exhaust)

Stations: 12 Stations, Port Size: C6 (ø6 One-touch Fitting), S Kit: SEA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Polarity: N (Negative Common), Option 1: None, DIN Rail Length: Standard (or None if w/o DIN Rail), Option 2: S (Built-in Silencer, Direct Exhaust)

Stations: 8 Stations, Port Size: N7 (1/4" One-touch Fitting), Kit Name: F (D-sub Connector 25 Pin), Electrical Entry: S (Side), Cable Length: 0 (w/o Cable 25 Pin), Option 1: None, Option 2: None, Option 3: None, Option 4: None, Option 5: S (Built-in Silencer, Direct Exhaust)