SMC Corporation of America
Elite Part Number Search
Search Results "VVQ5000-R-1-03"

Symbol 13 Main fluid connection size 1/2" Thread type Note 2) Symbol Nil N F Type Rc NPT G PAF341 S S 13 0 1 With nut Actuation Note 1) Option Fitting type Actuation Automatically operated Air operated Symbol 0 3 Symbol 1 3 Fitting type LQ1 LQ3 Applicable actuation Automatically operated Air operated Option Symbol Nil B N None With foot With silencer Fitting size Fitting type LQ1 IN side

IFW5 10 03 N 1 1 PSE Z I SE3 Diaphragm style flow switch PS Light 0 None Z I SE1 2 1 With neon light (110 VAC, Red) 2 With neon light (110 VAC, Green) Flow range ZSP 3 With neon light (220 VAC, Red) Low flow setting possible (1 l/min) 1 to 10 l/min 10 4 With neon light (220 VAC, Green) 10 to 20 l/min Simple flow setting Without removing the cover, you can set with a screwdriver from the

Modular Adapter How to Order E210/310/410 Series AC-A AF-A AF-A E310 03 U AR-A Size AL-A Piping port size 210 310 410 Size 310 Port size Uni thread AW-A Symbol 410 210 01 02 03 04 1/8 1/4 3/8 1/2 AC-B Thread AF-A Uni thread U AF-A AR -A -B Specifications AL-A Model E210 E310 E410 AW -A -B Port size 3/8 1/4 1/4 1/4 3/8 1/2 1/8 AW Piping I.D. 10 8 8 8 10 12 6 AG Fluid Air Ambient and fluid

Without nozzle KN-R02-100 KN-R02-150 KN-R02-200 KN-R02-250 VMG1-R02-300 VMG1-R02-350 VMG1-R02-400 KNH-R02-100 KNH-R02-150 KNH-R02-200 KNS-R02-075-4 KNS-R02-090-8 KNS-R02-100-4 KNS-R02-110-8 01 02 03 04 05 06 07 11 12 13 21 22 23 24 1 1.5 2 2.5 3 3.5 4 1 1.5 2 0.75 x 4 0.9 x 8 1 x 4 1.1 x 8 Connection size Piping connection method Symbol Size and model no.

How to Order 03 ADM200 1 Thread type Operating time/Applicable compressor Nil N F Rc NPT G Nil 2 sec/min (1 time/min) /3.7 to 37 kW 4 sec/min (2 times/min) /37 to 75 kW 6 sec/min (3 times/min) /75 to 110 kW 8 sec/min (4 times/min) /220 to 370 kW 4 6 8 Port size Voltage OUT IN Symbol 04 03 100 VAC Hz 1 3 8 3 8 50 60 200 VAC Hz 50 60 240 VAC Hz 50 60 110 VAC Hz 50 60 220 VAC Hz 50 60 24 VDC

HowtoOrder 03 ADM200 1 Threadtype Operatingtime/Applicablecompressor Nil N F Rc NPT G Nil 2 sec/min (1 time/min) /3.7 to 37 kW 4 sec/min (2 times/min) /37 to 75 kW 6 sec/min (3 times/min) /75 to 110 kW 8 sec/min (4 times/min) /220 to 370 kW 4 6 8 Portsize Voltage OUT IN Symbol 04 03 3 8 3 8 100 VAC Hz 1 50 60 200 VAC Hz 50 60 240 VAC Hz 50 60 110 VAC Hz 50 60 220 VAC Hz 50 60 24 VDC 12 VDC

FH150 Series How to Order 0 1 0 02 P 005 FH150 Made to Order Hydraulic filter Nil X0 None (Standard) Micromesh element equipped Port size (Rc) Note) Click here for details 02 03 04 1/4 3/8 1/2 Bracket Nil None With bracket B Differential pressure indication Nominal filtration None Differential pressure indicator Differential pressure indication switch Note) 0 4 5 005 010 020 5 m 10 m 20 m

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MANIFOLD BLOCK, VALVE, VV5Q51/55 NO SIZE RATING, 1.47709 lb

VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Fluid: air/inert gas, Operating pressure range: 0.10 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal

Specifications FGH200 FGH300 Model FGH100 Number of built-in elements (element length) (mm) 1(125) 1(250) 1(500) Operating pressure MAX. 1 MPa Operating temperature MAX. 80C (Not above the boiling point) Each kind of fluid (See the table of applicable fluids on pages 63 and 64) Applicable fluid Port size (Rc) 3/8, 1/2, 3/4, 1 Stainless steel 316 (Electrolytic polishing) Housing Material PTFE

TIE ROD, VQ, 4/5 PORT SOLENOID VALVE, 0.00000 lb

Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE

Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE

Series Pressure range 0~-101kPa PSE541 Vacuum pressure -101kPa 0Pa For air -100~100kPa PSE543 Compound pressure 100kPa -100kPa 1-16-4 Shimbashi, Minato-ku, Tokyo 105-8659, JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2002 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer

Connector type Connector type SMC Corporation 1-16-4 Shimbashi, Minato-ku, Tokyo 105-8659, JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2001 SMC CORPORATION All Rights Reserved 1st printing December, 2001 D-Export dept. P-100(D) Printed in Japan. This pamphlet is printed on recycled paper with concern for the global environment.

Industrial Filter FGD Series How to Order FGD C A 03 B N 002 Made to Order Symbol Element length Description None With differential pressure indicator Symbol Nil Element length L250 L500 (L250 x 2) A B X77 With differential pressure indication switch X78 Symbol Port size Port size Rc 3/8 1/2 3/4 Accessory 03 04 06 Accessory None Bracket Symbol Nil -B Symbol Element category Symbol Element

Body Size/Type: 32 (Elbow Size 03 Standard), Control Type: 1 (Meter-in), 1: 1, Thread Type: N (NPT), Port Size: 03 (3/8), Applicable Tubing O.D: 11 (ø3/8"), Sealant: S (w/Sealant)

Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min;

Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2"), VALVE FOR TRANSMISSION

Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE