Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: K (High-pressure, 1MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: Y (DIN EN175301-803 Terminal w/Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: D (Push-turn Locking Slotted Type), Port Size: 03 (3/8), Thread: F (G)
Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 0 (Meter-out), Model: 1FS, Thread: R (or None), Port Size: M5 (M5 x 0.8), Width Across Flats: 9 mm (or None: Sizes 2/3/4), Applicable Tubing: 03 (ø5/32"), Seal: without Sealant
Body Size: 40, Thread: N (NPT), Port Size: 03 (3/8), Option: D (N.O., Float Type Auto Drain), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 30, Thread: N (NPT), Port: 03 (3/8), Option: Standard, Attachment: V1 (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Function: 2 (2 Position, Double), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 03 (3/8), Thread: T (NPTF)
Body Size: 30, Thread: N (NPT), Port: 03 (3/8), Option: Standard, Attachment: V (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Stations: 3 Stations (Note: 2 Stations are Required for Serial Unit Mounting), Port Size: 03 (Rc3/8), Thread: Rc (PT), Kit Name: T (Terminal Box), Box Mounting Position: D (D Side Mounting), Control Unit: None, Release Valve Rated Voltage: w/o Air Release Valve, Option 1: None, Option 2: W (IP65 Protection Compatible)
Body Size: 30, Thread: N (NPT), Port: 03 (3/8), Option: C [Float Type Auto Drain (N.C.)], Attachment: S (Pressure Switch), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 30, Thread: Rc, Port Size: 03 (3/8), Option: D (N.O. Float Type Auto Drain), Attachment: V (3-Port Valve for Residual Pressure Release; Mounting: AF+AR+V), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: Standard
Type of Actuation: 2 (2 Position Double), Manifold Type: 40 (Base Mounted), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: E (Push-turn Locking Lever Style), Port Size: 03 (Base Mounted w/Sub-plate 3/8)
Type of Actuation: 2 (2 Position Double), Manifold Type: 40 (Base Mounted), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: W (M8 Connector w/ Connector), Lead Wire Length: 7 (5000mm), Surge Suppressor: None, Manual Override: Non-locking Push Style, Port Size: 03 (Base Mounted w/Sub-plate 3/8)
Body Size: 40, Thread: N (NPT), Port: 03 (3/8), Option: E [Square embedded type pressure gauge (with limit indicator)], Attachment: V1 (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Type of Actuation: 2 (2 Position Double), Manifold Type: 40 (Base Mounted), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: WO (M8 Connector w/o Connector), Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, Port Size: 03 (Base Mounted w/Sub-plate 3/8)
Type of Actuation: 2 (2 Position Double), Manifold Type: 40 (Base Mounted), Pilot: Internal Pilot, Specifications: Standard, Voltage: 3 (110VAC 50/60HZ), Electrical Entry: H (Grommet Lead Wire 0.6m), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 03 (Base Mounted w/Sub-plate 3/8), Thread: N (NPT)
Stations: 10 Stations (Note: 2 Stations are Required for Serial Unit Mounting), Port Size: 03 (Rc3/8), Mounting Base: SD (D Side), Kit Type: V (CC-Link, 16 Output Points), Option 1: None, Option 2: W (Dust Poof IP65 Rated)
Body Size: 30, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 03 (3/8), Option: DM (D + M), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: CG (C + G), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Actuation Type: 2 (2 Position Double), Sealant: 1 (Rubber Seal), Function: Standard (1W), Voltage: 5 (24VDC), Light & Surge Suppressor: w/Light and Surge Suppressor, Manual Override: Non-locking Push Style, Protection: Dust Proof, 1: 1, Piping Specification: Side Ported, Port Size: 03 (3/8), Thread: N (NPT)
Body Size: 30, Thread: N (NPT), Port: 03 (3/8), Option: Standard, Attachment: S (Pressure Switch), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 30, Thread: N (NPT), Port: 03 (3/8), Option: E [Square embedded type pressure gauge (with limit indicator)], Attachment: Standard, Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)