Fitting Type: H (Connector), Metric Size, Side A: 61 (Tube O.D. 3/4", Tubing Size mm 25x22), Inch Size, Side A: No (Select Metric Size, Side A), Metric Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Inch Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Piping: M (Male)
The tube holding mechanism gives the strong feeling when inserting tube, and prevents tube from sliding when screwing in the tube.Self-align fittings H, DL, L, LL, Applicable tube O.D: °4, °6 , °8 , °10 , °12, Maximum operating pressure: 1.0MPa, Proof pressure: 1.0MPa, Operating fluid: air, "FITTING, H DL L LL, SELF ALIGN FITTING, N lb
Length: 5m, Driver Type: S2 (LECSS2-T, 200-240V, Absolute, SSCNET III/H), I/O Connector: H (w/Connector)
Standard Cable), Cable Length: A (10m), Driver Type: S2 (LECSS2-T, 200-240V, Absolute, SSCNET III/H), I/O Connector: H (w/Connector)
Note 6) Fixed unit: Instantaneous flow: L/min, Accumulated flow: L Option 1 H Note 2) PNP External input Note 3) With lead wire and M8 connector (3 m) Note 4) Note 2) Made to Order Note 3) Can be selected from accumulated flow external reset and peak/bottom reset. Nil N Without lead wire and M8 connector Note 4) Each option is not assembled with the product, but shipped together.
Set value correction by auto-shift function Supply pressure normal Supply pressure drop Supply pressure increase P-1 Rectified Rectified Pressure (P-2) H-1 (H-2) ON Switch output 1(2) OFF Settable Range for Auto-Shift Input Range settings Settable range 0 to 2 kPa 2.30 to 2.300 kPa 0 to 101 kPa 115.0 to 115.0 kPa 100 to 100 kPa 210 to 210.0 kPa 0 to 100 kPa 115.0 to 115.0 kPa 0 to 500 kPa
Model XT13-394-06 XT13-394-10 INA-48-1-06 INA-48-1-10 INA-48-16-10 INA-48-16-06 INA-48-58-10-H INA-48-58-06-H Port size Rc3/4 Rc1 Rc3/4 Rc1 Rc3/4 Rc1 Rc3/4 Rc1 Relief mechanism Non-relief Relief Non-relief Fluid Deionized water (Pure water) Air, N2 Proof pressure 1.9 MPa 1.5 MPa Max. operating pressure 1.3 MPa 1.0 MPa Set pressure 0.1 to 1.0 MPa 0.05 to 0.5 MPa 5 to 60C Ambient and fluid
-H 4 W 100 L/min 200 Hz 1.7 0.55 -M 4 W 150 L/min 150 Hz 2.75 0.75 * Continuous energization is possible. 507 High Speed 2 Port Valve SX10 Series RoHS How to Order 2 F SX1 A G Lead wire (grommet) length Valve mounting Flow rate/Operating frequency (at 24 VDC, 0.25 MPa) Symbol Length G 300 mm H 500 mm J 1000 mm 1 Screw mount type Note) 2 Quick disconnect type Symbol Flow rate (L/min) Power
Note 3) When choosing with H (panel mount), the installation space for lead wires will not be secured. In this case, select wiring top entry for the lead wire entry. (Select wiring bottom entry when the semi-standard Y is chosen simultaneously.) Note 4) The only difference from the standard specifications is the pressure regulator spring.
Magnetically Coupled Rodless Cylinder Slider Type: Ball Bushing Bearing CY1L Series 6, 10, 15, 20, 25, 32, 40 How to Order Ball Bushing Bearing H 300 J79W CY1L 25 Refer to page 1517 for details. Slider type (Ball bushing bearing) Number of auto switches Auto switch Bore size Nil 2 pcs.
KPQ/KPG Series Clean One-touch Fittings How to Order KP H 06 KP P 08 Q 01 KQ2 Applicable fitting size Clean One-touch fittings Made to Order KQB2 04 06 08 10 12 4 6 8 10 12 Specifications X53 With pipe tape Grease-free Symbol Q G KS KX Specifications (metal part materials) Brass (electroless nickel plated) Stainless steel 304 Rubber material: EPDM (Fluorine-coated) X193 Note 1) Gasket: M-
: S (Standard Cable), Cable Length: 5 (5m), Driver Type: A1 (LECSA1-S, 100~120V, Incremental, Pulse Input), I/O Cable Length: H (w/Cable, Connector Only)
, Cable Type: S (Standard Cable), Cable Length: 5 (5m), Driver Type: A1 (LECSA1-S, 100~120V, Incremental, Pulse Input), I/O Cable Length: H (w/Cable, Connector Only)
, Cable Type: S (Standard Cable), Cable Length: 5 (5m), Driver Type: A1 (LECSA1-S, 100~120V, Incremental, Pulse Input), I/O Cable Length: H (w/Cable, Connector Only)
Cable), Cable Length: A (10m), Driver Type: S2 (LECSS2-T, 200~240V Absolute, SSCNETIII/H), I/O Cable Length: H (w/Cable, Connector Only)
Length: A (10m), Driver Type: A1 (LECSA1-S, 100~120V, Incremental, Pulse Input), I/O Cable Length: H (w/Cable, Connector Only)
: 5 (5m), Driver Type: 92 (LECSN2-T-9, 200~240V, Absolute, EhterNet/IPâ„¢ Card), I/O Cable Length: H (w/Cable, Connector Only)
Fitting Type: H (Connector), Metric Size, Side A: 46 (Tube O.D. 1/2", Tubing Size mm 6x4), Inch Size, Side A: No (Select Metric Size, Side A), Metric Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Inch Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Piping: M (Male), Thread: N (NPT)
Fitting Type: H (Connector), Metric Size, Side A: 21 (Tube O.D. 1/8", Tubing Size mm 6x4), Inch Size, Side A: No (Select Metric Size, Side A), Metric Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Inch Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Piping: F (Female)
Fitting Type: H (Connector), Metric Size, Side A: No (Select Inch Size, Side A), Inch Size, Side A: 2A (Tube O.D. 1/8", Tubing Size 1/4"x5/32"), Metric Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Inch Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Piping: F (Female), Thread: N (NPT)