SMC Corporation of America
Elite Part Number Search
Search Results "CDG3BN32-100-M9BL-C"

7 Piston rod Miniature linear guide Table Bumper A Bumper B Bushing Steel ball A Steel ball B Type C snap ring for hole Round head Phillips screw Magnet holder Auto switch Piston gasket Rod seal Piston seal Gasket r t y u i o !0 !1 !2 !3 !8 !

Changes from the standard type are: AP501mmA AP501 AP502 AP506 0.1 0.4 psig (0.0028 MPa) rise in delivery pressure per 20 psig (0.14 MPa) source pressure drop Option Other Parameters AP510 HF Cv Supply pressure effect Wetted Parts Material Flow Characteristics AP500 100 psig (0.69 MPa) Inlet pressure: 30 psig (0.21 MPa) Wetted Parts Body Surface finish Poppet Diaphragm Nozzle Seat S SH 316L

Applicable Stroke Table V: Standard Stroke [mm] Model 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1100 1200 LEFS25 V V V V V V V V V V V V V V V V LEFS32 V V V V V V V V V V V V V V V V V V V V LEFS40 V V V V V V V V V V V V V V V V V V V V * Please consult with SMC for non-standard strokes as they are produced as special orders.

See individual series information for replacements. 5 port solenoid valve, North American - old style see replacement series SYJ5000 - New Style , Operating pressure range: 20-100 PSI (2 pos sgl/3 pos.) 15-100 PSI (2 position double) , Response time (70PSI): 20ms (2 pos. sgl/dbl) 35ms (3 position) , Ambient and fluid temperature: Max. 120 F (50 C) , Lubrication: non-lube, VALVE SOL/PILOT

See individual series information for replacements. 5 port solenoid valve, North American - old style see replacement series SYJ5000 - New Style , Operating pressure range: 20-100 PSI (2 pos sgl/3 pos.) 15-100 PSI (2 position double) , Response time (70PSI): 20ms (2 pos. sgl/dbl) 35ms (3 position) , Ambient and fluid temperature: Max. 120 F (50 C) , Lubrication: non-lube, VALVE, SOL.

See individual series information for replacements. 5 port solenoid valve, North American - old style see replacement series SYJ5000 - New Style , Operating pressure range: 20-100 PSI (2 pos sgl/3 pos.) 15-100 PSI (2 position double) , Response time (70PSI): 20ms (2 pos. sgl/dbl) 35ms (3 position) , Ambient and fluid temperature: Max. 120 F (50 C) , Lubrication: non-lube, VALVE, SOL.

The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air, Cv factor: 0.008 standard style; 0.012 large flow capacity style, Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200, 220VAC, Response time: 10ms or less, Cycle life: 100 million cycles (by SMC life test), Ambient & fluid temperature: max. 50°C, "VALVE, 3 PORT SOLENOID

The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air, Cv factor: 0.008 standard style; 0.012 large flow capacity style, Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200, 220VAC, Response time: 10ms or less, Cycle life: 100 million cycles (by SMC life test), Ambient & fluid temperature: max. 50°C, VALVE, SOL, BASE MT,

Stations: 05 (Stations), Wiring: L (Individual Wiring or None), Manifold Options: D [with Common Release Pressure Supply (PD) Port], Exhaust: Q (Vacuum Pump System), Pressure Switch for Vacuum/Pressure Sensor: E (Digital Pressure Switch for Vacuum, -100 to 100, NPN 2 Outputs, with Unit Selection Function), Leadwire: without Leadwire, Unit Options: C [Vacuum Pump System PE Port Female Thread

The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air, Cv factor: 0.008 standard style; 0.012 large flow capacity style, Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200, 220VAC, Response time: 10ms or less, Cycle life: 100 million cycles (by SMC life test), Ambient & fluid temperature: max. 50°C, VALVE, SOL, BASE MT,

, 200, 220VAC , Response time (0.5MPa) w/o indicator light & surge voltage suppressor: 32ms or less , Ambient & fluid temperature: 50°C, INTRINSICALLY SAFE SOL VALVE., 4/5 PORT SOLENOID VALVE, VVD, 100 lb

The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air, Cv factor: 0.008 standard style; 0.012 large flow capacity style, Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200, 220VAC, Response time: 10ms or less, Cycle life: 100 million cycles (by SMC life test), Ambient & fluid temperature: max. 50°C, VALVE, SOL, BODY PT,

The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air, Cv factor: 0.008 standard style; 0.012 large flow capacity style, Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200, 220VAC, Response time: 10ms or less, Cycle life: 100 million cycles (by SMC life test), Ambient & fluid temperature: max. 50°C, VALVE, SOL, 3 PORT SOLENOID

to 100 kPa), Unit specifications: With unit selection function, Lead wire specifications: Lead wire with connector, Accessory: No, Vacuum switch electrical entry: With lead wire for sensors, Vacuum break flow adjusting needle: No, Options: -

to 100 kPa), Unit specifications: With unit selection function, Lead wire specifications: With dedicated lead wire for switch with energy-saving function, Accessory: With 1 bracket for single unit (mounting screws attached), Vacuum switch electrical entry: With dedicated lead wire for switch with energy-saving function, Vacuum break flow adjusting needle: No, Options: -

to 100 kPa), Unit specifications: With unit selection function, Lead wire specifications: With dedicated lead wire for switch with energy-saving function, Accessory: No, Vacuum switch electrical entry: With dedicated lead wire for switch with energy-saving function, Vacuum break flow adjusting needle: Screwdriver operation type, Options: -

to 100 kPa), Unit specifications: -, Lead wire specifications: Lead wire with connector, Accessory: No, Vacuum switch electrical entry: With lead wire for pressure switches, Vacuum break flow adjusting needle: Screwdriver operation type, Options: -

to 100 kPa), Unit specifications: -, Lead wire specifications: Lead wire with connector, Accessory: No, Vacuum switch electrical entry: With lead wire for pressure switches, Vacuum break flow adjusting needle: Screwdriver operation type, Options: -

to 100 kPa), Unit specifications: With unit selection function, Lead wire specifications: With dedicated lead wire for switch with energy-saving function, Accessory: No, Vacuum switch electrical entry: With dedicated lead wire for switch with energy-saving function, Vacuum break flow adjusting needle: No, Options: -

to 100 kPa), Unit specifications: With unit selection function, Lead wire specifications: With dedicated lead wire for switch with energy-saving function, Accessory: No, Vacuum switch electrical entry: With dedicated lead wire for switch with energy-saving function, Vacuum break flow adjusting needle: Screwdriver operation type, Options: -