Piston seal NBR Cushion valve seal NBR O-ring MBW100-PS Cylinder tube gasket NBR Do not disassemble the trunnion style. Seal kit includes !2, !3, !4 and !6. Order the seal kit based on each bore size. Seal kit includes a grease pack (40, 50: 10 g, 63, 80: 20 g, 100: 30 g). Order with the following part number when only the grease pack is needed.
CA2WH100A-PS Do not disassemble the trunnion style. Seal kit includes !0, !1 and !2. Order the seal kit based on each bore size. Seal kit includes a grease pack (40, 50: 10 g, 63 or more: 20 g). Order with the following part number when only the grease pack is needed. Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) 41
Do not indicate suffix N for no lead wire on D-A3/A44/G39/K39 models. -X Lead wire length symbols: 0.5 mNil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN Individual -X Since there are other applicable auto switches than listed, refer to page 1214 for details.
Model: 32, Orifice: 2 (2.2mm), Style: 0 (N.C., Single Unit), Option: C37, Seals: NBR, Class B, Suffix: Standard, Port Size: 02 (1/4), Thread: N (NPT), Voltage: 5 (24VDC), Electrical Entry: DO (DIN Terminal, w/o Connector, Gasket Included), Surge Suppressor: Non, Rectifier: None (for DC or AC Class H Coil)
duty scraper Mounting Basic Foot Rod ange Head ange Single clevis Double clevis Standard Rod end nut V V V V V V Clevis pin V Option Rod end V V V V V V Rod clevis V V V V V V Rod boot V V V V V V -XC7 Tie-rod, tie-rod nut, etc. made of stainless steel -XC10 Dual stroke cylinder/Double rod type -XC11 Dual stroke cylinder/Single rod type -XC22 Fluororubber seal -XC35 With coil scraper * Do
Function: 2 (2 Position Double), Piping: 3 (Body Ported), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: DO (DIN Connector w/o Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, A, B Port Size: 02 (1/4), Thread: T (NPTF)
Do not touch the valve by hand directly. When there is such a dangerous case to be touched by hands directly, install a protective cover. Simultaneous energization protection circuit A()Set Simultaneous energization protection circuit Black () A-ON A Red (+) COM. SOL. C(+)COM SOL.
Body Size: 4000, Thread: F (G), Port Size: 04 (1/2), Option: G (Round Type Pressure Gauge w/Limit Indicator), Voltage: 5 (24 VDC), Lead Wire: DO (Type D, DIN Terminal w/o Connector), Surge Suppressor: None, Manual Override: B (Push-turn Locking Slotted Type), Flow Direction/Pressure Unit: Flow Direction: Left to Right
Type: 332 (Body Ported), Valve Option: V (For Vacuum), Rated Voltage: 5 (24 VDC), Electrical Entry: DO (DIN Terminal w/o Connector), Light/Surge Voltage Suppressor: None, Port Size: M5 (M5 x 0.8)
Function: 1 (2 Position Single), Piping: 4 (Base Mounted), Exhaust: 3 (Common), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: DO (DIN Terminal w/o Connector), Surge Suppressor: S (Surge Suppressor)
Do not indicate suffix N for no lead wire on D-A3A/A44A/G39A/K39A models.
clevis type Double clevis type Center trunnion type Front trunnion type 40 50 63 80 100 40mm 50mm 63mm 80mm 100mm Nil J K Nil N R H Without rod boot Nylon tarpaulin Neoprene cloth Both sides Without cushion With front cushion With rear cushion Aluminum tube Rod boot Part nos. for cylinders with built-in magnets Cushion In the case of cylinders with built-in magnets but no auto switches, do
Do not use two cylinders facing one another horizontally or vertically in such a way that their piston rods strike each other. 8. When the cylinder head side contains hydraulic fluid or is in a normally pressurized condition, the applied load must not be allowed to strike the piston rod end.
Do not use two cylinders facing one another horizontally or vertically in such a way that their piston rods strike each other. 9. When the cylinder head contains fluid or is in a normally pressurized condition, the load should not be allowed to strike the piston rod end. Avoid such applications.
For rail mounting type auto switches, do not remove the rails that are mounted. Since the mounting screw penetrates into the cylinder, the removal of the rails will cause air leakage. Axial direction Perpendicular to axis Auto Switch Mounting Bracket Part Nos. (Band Mounting Type) Mounting Bracket Part Nos. Operation Warning Auto switch mounting bracket part no.
Do not add the suffix (N) indicating no lead wire to the part numbers of models D-A3A, A44A. G39A and K39A. Lead wire length 0.5 m Nil (Example) C73C 3 m L (Example) C73CL 5 m Z (Example) C73CZ None N (Example) C73CN In addition to the models in the above table, there are some other auto switches that are applicable.
Do not connect the white wire of the sensor to c of the display unit.
Rack-and-Pinion Type/Sizes: 10, 15, 20, 30, 40 Series CRQ2 Piping can be installed from one end Body can be used as a flange Compact design saves mounting space Uses internal cushioning 10, 15 : Rubber bumper 20, 30, 40: Air cushion 10: 17mm 15: 20mm 20: 29mm 30: 33mm 40: 37mm 2 auto switches can be mounted on same side (both sides) Angle adjustment bolts are standard Miniature auto switches do
(between lead wire and case) Ambient temperature 10 to 60C Enclosure IEC529 standard IP67, JISC0920: Watertight construction Contact Protection Box/CD-P11, CD-P12 Lead Wire Length D-A9 and D-A9V do not have built-in contact protection circuits. a The operating load is an induction load. b The length of wiring to the load is 5 m or more. c The load voltage is 100 VAC.
Parenlneses CPA1 BN do Boot with Boot' BORE D E G'GB J K M MM N P H z.