ZSE6 ISE6 8 10 ZSE3 ISE3 l50 l45 l48 56 70 4.5 (MAX.8) 35.5 12.5 GS PS ISA 9 8 7 6 10 ZSE1 ISE1 17 10-M3 ZSE2 ISE2 11 23 6 38 50 ZSP 48 (54) ISl ZSM DIN rail L PFl 7.5 10 25 5 IFl 4.5 35 27 Material: Aluminum Part number of DIN rail Part number ISA-2-1 ISA-2-2 ISA-2-3 ISA-2-4 ISA-2-5 ISA-2-6 ISA-2-7 L 105 140 175 210 245 280 315 3.1-14

Applicable Element size Element O-ring filter model mm for cover I-34S-A ZFB10 10 x 6 x L33 10 pcs. 10 pcs. I-35S-A ZFB20 12 x 8 x L42 10 pcs. 10 pcs. I-36S-A ZFB30 14 x 10 x L45 10 pcs. 10 pcs. I-39S-A ZFA401 16 x 14 x L60 10 pcs. 10 pcs. -9- < Element Replacement > 1. Stop the operation and reduce the internal pressure of the filter to atmospheric pressure. 2.

Symbol Applicable stations Mounting position U side D side Both sides M Special specifications 2 to 10 stations 2 to 10 stations 2 to 16 stations D U B Indicate special specifications separately on a manifold specification sheet. Note 2) The number of blanking plate assemblies is also included.

ZSE20 ISE20 ZSE30 ISE30 ZSE30 ISE30 1 unit 2 units 10 units ZSE40 ISE40 ZSE10 ISE10 Master Slave (Max. 10 units) ISE70 Wiring example when using ZS-38-U Slave-side sensor Master-side sensor Slave-side sensors (up to 10 sensors) ZSE80 ISE80 Master-side sensor 1 unit 2 units n units (Up to 10 switches) Brown: DC+ PS DC (+) OUT1 OUT2 FUNC DC () DC (+) OUT1 OUT2 FUNC DC () DC (+) OUT1 OUT2 FUNC

4 inputs 1 input Calibration method Push-button calibration Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.1 to 1 MPa 10 to 101 kPa 100 to 100 kPa 10 to 100 kPa 50 to 500 kPa 0.1 to 1 MPa 10 to 101 kPa 101 to 101 kPa 10 to 100 kPa Set pressure range 0.2 to 2 kPa

(mm) 1 8 1 4 3 8 1 2 1 8 1 4 3 8 1 2 1(P) 1(P) M5 4 6 8 10 12 1(P) 1(P) M5 4 6 8 10 12 Applicable tubing O.D. (mm) Applicable tube O.D. (mm) Applicable tubing O.D.

Reed Auto Switch: D-A93 (mm) Stroke B A Stroke C Auto switch operating range Stroke Model 5 10 15 20 5 10 15 20 5 10 15 20 11-MXJ4 11-MXJ6 11-MXJ8 14 14 0.5 0.5 9 4 4 3 14 14 18 0.5 0.5 0.5 9 4 10 5 25 14 14 25 0.5 0.5 0.5 0.5 9 4 Solid State Auto Switch (Lead Wire, In-line Entry): D-M9 (mm) Stroke B A Stroke C Stroke Auto switch operating range Model 5 10 15 20 5 10 15 20 5 10 15 20

Note 1) C 5 to 35 Cooling capacity 50/60 Hz Note 3) kW 9.0/9.5 13.0/14.5 Heating capacity 50/60 Hz Note 4) kW 1.7/2.2 2.5/3.0 Temperature stability Note 5) C 1.0 Circulating uid system Rated ow 50/60 Hz (Outlet) Note 6) L/min 42/56 Maximum ow rate 50/60 Hz L/min 55/68 Maximum pump head m 50 Minimum operating ow rate 50/60 Hz Note 7) L/min 28/42 Tank capacity L 18 Circulating uid outlet, circulating

(V) 24 Allowable voltage fluctuation -10 to 10% Power consumption (W) 0.4 [Starting 0.4, Holding 0.1] Please refer to page 1367 of Surge voltage suppressor the Best pneumatics catalogue.

Flow Rate and Effective Area AS1001F AS2001F AS3001F AS2051F AS4001F Model 3.2, 4, 6 4 6 6 8 6 8 10, 12 10 12 Metric size Tubing O.D. 1/8" 5/32" 3/16", 1/4" 3/16" 1/4" 1/4" 5/16" 3/16" Inch size 1/4" 5/16" 3/8" 3/8" 1/2" 5/32" Flow rate (l/min(ANR) 290 460 230 100 130 420 660 920 1050 1390 Controlled flow (Free flow) 4.5 7 3.5 1.5 2 6.5 10 14 16 21 Effective area (mm2) Note) Flow rate values

16 20 25 12 16 20 25 Relief type Vacuum suction type 5, 10, 15, 20, 25, 30 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 M5 x 0.8 M5 x 0.8 Double acting Single rod 5, 10, 15, 20, 25, 30 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 Suction Flow Rate of Vacuum Suction Type (Reference values) Specifications Suction flow rate L/min (ANR) Bore size (mm) 12/16/20/25 Size 5 12/16/20/25 Item Proof pressure 1.5

Flow Rate and Effective Area AS1001F AS2001F AS3001F AS2051F AS4001F Model 3.2, 4, 6 4 6 6 8 6 8 10, 12 10 12 Metric size Tubing O.D. 1/8" 5/32" 3/16", 1/4" 3/16" 1/4" 1/4" 5/16" 3/16" Inch size 1/4" 5/16" 3/8" 3/8" 1/2" 5/32" Flow rate (l/min(ANR) 290 460 230 100 130 420 660 920 1050 1390 Controlled flow (Free flow) 4.5 7 3.5 1.5 2 6.5 10 14 16 21 Effective area (mm2) Note) Flow rate values

Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT SLIDE TABLE, ACTUATOR, MXH HIGH RIGIDITY GUIDE CYL, EE, 10MM MXH DBL-ACT AUTO-SW, .31841 lb, ModelBore size (mm)Standard stroke (mm)Made to Order 51015202530405060MXH1010------------------XB13 : Low-speed cylinder (5 to 50 mm/s)XC3 : Special port positionsXC19 : Intermediate stroke (Spacer type)XC22 : Fluororubber

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, DUAL STK, ACTUATOR, CQ2 COMPACT CYLINDER, RC, 80MM CQ2 OTHERS (COMBO), .00000 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, ISO, SW CAPABLE, ACTUATOR, C55 ISO COMPACT CYLINDER, IE, 25MM C55 DBL-ACT AUTO-SW, .76485 lb

Assembly and disassembly of the SI unit -25No.EX-OMV0023-A Specifications Specifications General specifications Item Specifications Ambient temperature -10 to +50 oC Ambient humidity 35 to 85%RH (No condensate) Ambient temperature for storage -20 to +60 oC Withstand voltage 500 VAC applied for 1 minute Insulation resistance 500 VDC, 10 M or more Operating atmosphere No corrosive gas Enclosure

Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2009 SMC Corporation All Rights Reserved Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: +81 3-5207-8249 Fax: +81 3-5298-5362 -10 to 50 oC (Max. surrounding air temperature rating: 50 oC) Operating temperature range The status display LED shows

Specifications Specifications Bore size (mm) 16 Fluid Air Operating pressure [MPa] 0.1 to 0.7 Ambient and fluid temperature (oC) -10 to 50 Repeatability (mm) 0.01 Maximum operating frequency (c.p.m.) 120 Lubrication Non-lube Action Double acting External gripping Force (N) 32.7 Gripping force Actual value per finger (N) Internal gripping Force (N) 43.5 Opening/closing stroke (both) (mm) 10

Caution Standard stroke (mm) Note) Bore size (mm) 20 25 32 40 50 63 80 100 25, 50, 75, 100, 125, 150, 200 25, 50, 75, 100, 125, 150, 200, 250, 300 Note) Manufacture of intermediate strokes in 1 mm increments is possible. (Spacers are not used.)

CH2 H B B 50 100 CH D2 H B B 50 100 M9BW With Auto Switch With auto switch (built-in magnet) Port and cushion valve positions Refer to page 359. Bore size 32 40 50 Mounting type 63 80 100 32 mm 40 mm 50 mm 63 mm 80 mm 100 mm Made to Order specifications For details, refer to page 359.