When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN

Bore sizes: 16, 25, 40, 63 mm; Stroke lengths: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000, 3000 mm; Minimum operating pressure: 0.15 ~ 0.20 MPa (22 ~ 29 psi); Speed: 80~1000 mm/sec (w/o stroke adjustment bolt), 80~1500 mm/sec (external shock absorber); Long stroke option: up to 3000 mm (XB11); Auto switch capable

Bore sizes: 10, 15, 20, 25, 32 mm; Stroke lengths: 150, 200, 300, 400, 500, 600, 800, 1000 mm; Maximum stroke lengths: 500 mm (10 bore), 750 mm (15 bore), 1000 mm (20 bore), 1200 mm (25 bore), 1500 mm (32 bore); Minimum operating pressure: 0.2 MPa (29 psi); Speed: 70 ~ 300 mm/sec.

Bore sizes: 25, 32, 40 mm; Stroke lengths: 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 mm; Minimum operating pressure: 0.10 MPa (15 psi); Speed: 100~1000 mm/sec (air cushion), 100~1500 mm/sec (external shock absorber); Long stroke option: up to 1500 mm (XB11); RoHS compliant; Auto switch capable

Bore sizes: 6, 10, 15, 20, 25, 32, 40, 50, 63; Stroke lengths: 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1500, 3000, 5000 mm; Minimum operating pressure: 0.12 ~0.16 MPa (17 ~ 23 psi); Speed: 50 ~ 500 mm/sec.; Fluorine grease; ISO Class 5 (Class 100)

The MXY is a long stroke precision slide table, light weight in design that provides constant rigidity throughout the entire stroke, up to 400 mm. It is integrated with hardened stainless steel guides and rails to isolate the load bearing from the movement of the piston rod and seals.

Double acting, single rod; Bore size (mm):  40, 50, 63; Standard stroke (mm): 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500; Rc, NPT or G port threads; Clean series

Bore sizes: 25, 32 40, 50, 63 mm; Stroke lengths: 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 mm; Maximum stroke length: 1300 mm (25, 32, 40, 50 & 63 bore); Minimum operating pressure: 0.18 MPa (26 psi); Speed: 50 ~ 300 mm/sec.

Body sizes: 40 (100W), 63 (200W), 100 (750W); Maximum workload: 55 kg (size 40), 85 kg (size 63), or 400 kg (size 100); Maximum speed: 2300 mm/s (size, lead, and stroke dependent); Maximum stroke: 1500 mm; Positioning repeatability: ±0.01mm (size and lead dependent); Motor encoders: incremental 17-bit; absolute 18- or 22-bit

Stroke lengths (mm): 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000; Minimum operating pressure: 0.12 ~ 0.16 MPa (17 ~ 23 psi); Bore sizes (mm): 6, 10, 15, 20, 25, 32, 40, 50, 63; Series 25A-CY3B is compatible with secondary battery applications

Double acting, guided actuator ; High temperature(XB6)Bore sizes(mm): 12, 16, 20, 25, 32, 40, 50, 63, 80, 100 ; Slide bearing type ; Standard stroke range (mm): 10 to 400 ; Port threads: M (12 to 25 bore), Rc, NPT or G (32 to 100 bore) ; High temperature option (XB6) ambient range -10 to 150°

Manufacturers include Mitsubishi, Yaskawa, Sanyo Denki, Omron and Panasonic Body sizes: 40 (100W), 63 (200W), 100 (750W); Maximum workload: 55 kg (size 40), 85 kg (size 63), or 400 kg (size 100); Maximum speed: 2300 mm/s (size, lead, and stroke dependent); Maximum acceleration:: 20,000 mm/s² (40, 63) 9,800 mm/s² (100); Positioning repeatability: ±0.01mm (size and lead dependent); Stroke range

Compatible motors (W): 100/200/400; Power supply voltage (VAC, 50/60Hz); 200~230; STO (Safe Torque Off) safety function available; Display and settings buttons for direct input and status monitoring; Compliant with SEMI F47 Standard; SigmaWin+ Configuration software required (download available separately)

Two models available: ZVB40 (single ionizer) = 210 W x 297 D x 351 H (mm), ZVB40 (double ionizer) = 400 W x 384 D x 390 H (mm); Static electricity removal performed by an IZN10 nozzle iionizer; Static neutralization in 1 second or less; Ion balance is ±10V; Accessories include exhaust hose, dust bag, and AC adapter  

Bore sizes (mm): 6, 10, 15, 20, 25, 32, 40, 50, 63; Stroke lengths (mm): 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000; Minimum operating pressure: 0.12 ~ 0.16 MPa (17 ~ 23 psi); Direct mount type; Auto switch capable; Series 25A-CY3R is compatible with secondary battery applications

Power supplies are available in 200 and 400 VAC 3-phase, and function in both 50 and 60 Hz environments for global compatibility. Alarms report on a variety of circuit and equipment conditions to preserve optimal operation.

Compatible motors (W): 100/200/400; Power supply voltage (VAC, 50/60Hz): 100~120V no longer available; 200~230 (LECSS-S); 200~240 (LECSS-T); Display and settings buttons for direct input and status monitoring; LEC-MRC2 Configuration software required (sold separately); C-UL-US listed (LECSS2-T only)

Positioning table points: 255; Compatible motors (W): 100/200/400; Power supply voltage (VAC, 50/60Hz): 200~230; Display and setting buttons for direct input and status monitoring; LEC-MRC2 Configuration software required (sold separately); C-UL-US listed (LECSC2-T only)

Body size: 25; Maximum work load: 9 kg (horizontal), 4 kg (vertical); Maximum pushing force: 180 N; Maximum speed: 400 mm/s; Strokes: 50, 100, 150; Positioning repeatability: ±0.05mm

Body size: 25; Maximum work load: 5 kg (horizontal or vertical); Maximum pushing force: 180 N; Maximum speed: 400 mm/s; Strokes: 30, 50, 75, 100, 125, 150mm; Positioning repeatability: ±0.05mm