Barb fitting Barb elbow Barb elbow (H) Surface treatment (Color) Fitting marking for applicable tube material Connection Tube Soft nylon tube Polyurethane tube Electroless nickel plating (Silver color) M3 Electroless nickel plating (Silver color) Nylon tube 1 8 R(PT) , M5 Electroless nickel plating (Black color) [Except stud] Soft nylon tube Polyurethane tube M-5E, M-5ER, M-5M do not have

(between lead wire and case) 1000VAC for 1min (between lead wire and case) Withstand voltage Ambient temperature 10 to 60C enclosure IEC529 standard IP67, JISC0920 watertight construction Contact Protection Boxes/ CD-P11, CD-P12 Lead Wire Length Lead wire length indication L D-Y59A D-Z7, Z8 The above auto switches do not have internal contact protection circuits. 1.

Load connection fittings should be designed so that they do not exceed the weights given in the table below.

Do not connect the white wire of the sensor to c of the display unit. View A Terminal block number 4 3 2 1 1 2 3 4 5 6 7 8 8 7 6 5 Series PF2D For Deionized Water and Chemicals Digital Flow Switch Functions/PF2D Refer to the operation manual how to set and to operate. Output types Flow rate measurement selection Real-time flow rate and accumulated flow rate can be selected.

Thanks to a tool-free module press-in connector, all you need to do is to simply snap-in the lead wire and lock it! Crimping tools are not required. The connection cable is a halogen-free heavy-duty cord.

(Do not cut the tube with plier6, nippers, scissors, utilitv knife, etc.) ePull out the tube while keeping the release button depressed. lJf the release butlon is nol held down, the tube cannot be withdrawn.) OGrasp the tube, then slowly push it until il comes lo a dead-end.

vacuum pressure: 100kPa (when downstream flow rate is 0l/min (ANR)) 20 0.5 Output deviation (%F.S.) 30 Maximum flow rate: 132l/min (ANR) (with upstream VAC. pressure at 39kPa) Set pressure (kPa) 40 0 50 60 0.5 70 80 90 1.0 100 80 60 40 20 50 100 150 Flow rate (l/min) (ANR) VAC side pressure (supply pressure) (kPa) 2 Solid State Vacuum Regulator Series ITV209 Dimensions ITV2090 Note) Do

Internal voltage drop in switch is 4V. 8 Series MGF Contact Protection Boxes/CD-P11, CD-P12 Auto Switches Proper Mounting Position for Stroke End Detection D-Z7 and D-Z8 type switches do not have builtin contact protection circuits. A contact protection box should be used in any of the following cases. B A 1. The operated load is an induction load. 2.

Double wiring specification manifolds which do not have the maximum number of stations, contain spare receptacle housings for expansion in the housing holder of the last station, or inside the supply/exhaust block assembly (for a maximum of 2 stations). When expanding stations, perform the disassembly and assembly of the manifold while referring to the expansion method shown below. 1.

Application examples illustrated in this flyer do not guarantee the result of applicable use of this product. Construction Tubing Integral fittings e y t e t i r y !6 r u i u q o q !0 o !1 !0 w !1 !2 w !2 Parts list !3 No.

Able to strip without damaging the inner tubing Do not use to strip covering materials from electrical wires, etc. Caution The outer tubing can be stripped without damaging the inner tubing because a pawl is inserted between the inner and outer tubing layers.

Hole diameter 5 9 Features 1 3 Port Direct Operated Poppet 3 Port Direct Operated Poppet Solenoid Valve Series VKF300 How to Order Valves Electrical entry Rated voltage 100VAC 50/60 Hz 200VAC 50/60 Hz 110VAC 50/60 Hz 220VAC 50/60 Hz 24VDC 12VDC 240VAC 50/60 Hz Other DO-DIN terminal (without connector) 1 2 3 G-grommet (lead wire length: 300mm) H-grommet (lead wire length: 600mm) D-DIN type

Do not use in locations where there is splashing or spraying of oils and solvents. OUT2 OUT1 3. When using a commercially available switching regulator, be sure to ground the FG terminal. SET 4. In locations where the switch is exposed to water and dust, etc., these may enter the switch from the atmospheric release port.

Model: 21, Orifice Diameter: 1 (2 mm), Valve/Body Configuration: 1 (N.C. for Manifold), Solenoid Valve Option: Brass Body (Aluminum for Air Type), NBR Seal, Class B, Suffix: Standard, Manifold Designation: 00 (Aluminum Base Material), Voltage: 5 (24VDC), Lead Wire: DO (DIN Connector without Connector)

Do not allow the weight of piping to lie directly on air dryer. Operating Environment Caution The air that has been used for reactivating the adsorption agent and the air that has passed through the indicator are discharged externally from the heatless air dryer. Therefore, use the dryer in an area where the discharge will not be a problem.

0.105 to 1.100 MPa4 MPaPressure sensor: Stainless steel 630, Fitting: Stainless steel 304Fluids do not corrode stainless steel 630 and 304R1/4, NPT1/4, G1/4?, URJ1/4, TSJ1/4, Rc1/8Piping direction: Rear/Bottom12 to 24 VDC ?

0.105 to 1.100 MPa4 MPaPressure sensor: Stainless steel 630, Fitting: Stainless steel 304Fluids do not corrode stainless steel 630 and 304R1/4, NPT1/4, G1/4?, URJ1/4, TSJ1/4, Rc1/8Piping direction: Rear/Bottom12 to 24 VDC ?

0.105 to 1.100 MPa4 MPaPressure sensor: Stainless steel 630, Fitting: Stainless steel 304Fluids do not corrode stainless steel 630 and 304R1/4, NPT1/4, G1/4?, URJ1/4, TSJ1/4, Rc1/8Piping direction: Rear/Bottom12 to 24 VDC ?

0.105 to 1.100 MPa4 MPaPressure sensor: Stainless steel 630, Fitting: Stainless steel 304Fluids do not corrode stainless steel 630 and 304R1/4, NPT1/4, G1/4?, URJ1/4, TSJ1/4, Rc1/8Piping direction: Rear/Bottom12 to 24 VDC ?