(B) 12 (C) 13 (D) 14 (E) Position number 1 (End side) 2 (Motor side) 3 4 5 6 7 8 9 10 (A) 11 (B) 12 (C) 13 (D) 14 (E) 50 Series LECP2 Signal Timing (1) Positioning Operation [Driving to the stroke end] (4) Stop by the STOP Signal 24 V 0 V 24 V 0 V Power supply Power supply ON OFF ON OFF IN0 or 1 IN0-3 Input Input ON OFF OUT0 or 1 STOP Output ON OFF BUSY OUT0-3 Release Hold BUSY External
75 1.0 0 2 6 4 8 1.0 100 0 25 50 75 10 Input signal (%F.S.)
Metric size Inch size 3.2 01 03 05 07 09 11 23 04 06 08 10 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" Control type 4 6 8 10 0 1 Meter-out Meter-in Use 1/8" tube.
How to Order Dimensions LQ1 fitting size: 3 1S PF2D504 S 11 (186) 70 58 1 27.5 9.53 With LQ1 fitting Size OUT side 3 4 (With reducer) 3 4 (With reducer) IN side 3 3 4 (With reducer) 4 (With reducer) Model 11 1113 1311 13 LQ1 fitting size: 4 58 1 33 9.53 LQ1 fitting size: 4 13 1S PF2D520 S (186) 70 58 1 33 With LQ1 fitting 12.7 Size OUT side 4 5 (With reducer) 4 5 (With reducer) Model 13
-R () NPN 2 Max.28 V80 mA 1 V R15 V 1 k S420 mA 12 V 300 24 V 600 50 -S/-R () NPN 2 Max.28 V80 mA 1 V -X () -S/-R () NPN 2 Max.28 V80 mA 1 V -21No.PS-OMU0005CN-C -V/-T () PNP 2 Max.80 mA 1 V T15 V 1 k V420 mA 12 V 300 24 V 600 50 -V/-T () PNP 2 Max.80 mA 1 V -Y () -V/-T () PNP 2 Max.28 V80 mA 1 V -22No.PS-OMU0005CN-C [] 3 0.2 [] / OUT2 OUT2 OUT1 OUT1 [F10]30 () 13
1 4, 6 (Oval type release button) Oval type release button KQ2 8 to 16 H 08 01 G S (Round type release button) Male thread seal method Symbol Seal method Nil Without sealant S With sealant Model Thread material: Stainless steel 303 One-touch fittings Port size/Applicable tubing O.D.
(U, D)-SCS1 EX124 (U, D)-SCS2 EX140-SCS1 EX140-SCS2 EX120/121/122-STA1 EX123(U, D)-STA1 IN313-TA1 N N Y Y 16 8 16 8 16 8 16 16 16 16 8 16 8 0 0 0 0 0 0 0 0 0 0 0 0 0 VQ, SX, SY & SV VQ2000/4000/5000 CompoBus/S OMRON N N N Y SQ1000/2000, SZ3000/5000 VQ, SX, SY & SV VQ2000/4000/5000 (N)VFR/S, (N)VZS, ISO SYSBUS N EX120/121/122-SSL1 N VQ, SX, SY & SV EX120/121/122-SSL2 N S-Link SUNX EX123 (
Viscosity: Transfer is possible up to about 100mPa s. 50 0 1 2 3 4 5 10 20 30 40 50 100 Viscosity (mPas) 17 Process Pump Series PB1000 Built-in Solenoid Valve Type/Air Operated Type Operating Principle/Built-in Solenoid Valve Type/Air Operated Type Discharge port (FLUID OUT) Diaphragm Drive chamber Return spring Built-in solenoid valve (3 port valve) The PB1013 air operated type does not
Viscosity: Transfer is possible up to about 100mPa s. 50 0 1 2 3 4 5 10 20 30 40 50 100 Viscosity (mPas) 17 Process Pump Built-in Solenoid Valve Type/Air Operated Type Series PB1000 Operating Principle/Built-in Solenoid Valve Type/Air Operated Type Discharge port (FLUID OUT) Diaphragm Drive chamber Return spring Built-in solenoid valve (3 port valve) The PB1013 air operated type does not
P . 15-11-3 15-9-2 2 Speed Controller with One-touch Fitting Elbow Type/Universal Type Series AS How to Order 2 2 0 01 06 S AS 1F Nil Option Body size 1 2 3 4 M3, M5 standard 1/8, 1/4 standard 3/8 standard 1/2 standard None With seal Hexagonal lock nut Electroless nickel plated S K N If more than one option is required, write option part numbers in the order of S, K, N.
DC(+) 5 OUT1 4 OUT2 3 FUNC 2 DC(-) 1 -19No.PS-OMU0002CN-D Z/ISE20A(F)-S/-R () DC(+) NPN 2 Max.28 V80 mA 1 V R15 V OUT1 1 k OUT2 S420 mA DC(-) 12 V 300 24 V 600 50 DC(+) -S/-R () OUT1 NPN 2 OUT2 Max.28 V80 mA 1 V DC(-) DC(+) -X () -S/-R () OUT1 NPN 2 OUT2 Max.28 V80 mA 1 V DC(-) -20No.PS-OMU0002CN-D -V/-T () DC(+) PNP 2 Max.80 mA 1 V T15 V OUT1 1 k OUT2 V420 mA DC(
25 32 40 6 12 6 CY1L10 15 CY1L20 CY1L25 CY1L32 40 Applicable rodless cylinder CYP 5.5 11 3.5 7 RB0805 RB1006 RB1411 RB2015 Shock absorber model 5.5 11 0.98 3.92 14.7 58.8 Maximum energy absorption: (J) 5 10 Stroke absorption: (mm) 5 6 11 15 5.5 11 Collision speed: (m/s) 0.05 to 5 4.5 9 Max. operating frequency: (cycle/min) 80 70 45 25 Since the cylinder is in an intermediate stop condition
Note 2) V, S and R specifications are 45T, 45T1.
R 28 34 40 50 S 83 106 111 124 150 W 35 50 50 50 60 X 19 25 30 40 40 Model 12-CY3B15 12-CY3B20 12-CY3B25 12-CY3B32 12-CY3B40 P (Piping port) Model Mounting nuts (2 pcs.) are shipped together.
Thread type Voltage Rc G NPT Nil F N 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Port size Please consult with SMC regarding other voltages.
1 q t i 16-11-40 5 Series PF2D Digital Flow Switch For Deionized Water and Chemicals Dimensions: Separate Type Sensor Unit PF2D504-11/520-13 Internal circuit and wiring example 60 70 176 z to , are terminal numbers.
Relationship between the kinematic viscosity Ratio of amount of discharge against clear water (%) 100 50 0 1 2 3 4 5 10 20 30 40 50 100 Viscosity (mPas) Kinematic viscosity [m2/s] = Viscosity [Pas]/Density [kg/m3] Transfer is possible up to about 100 mPas. 1 cP = 1 mPas = 10-3Pas 1 cSt = 1 mm2/s = 10-6m2/s 585 PB1000A Series Working Principle: Built-in Solenoid Valve/Air Operated Discharge
37 10 14 9 55 88 110 50 9 3.2 37 37 10 16 9 65 102 130 60 10 4.5 39 37 15 20 11 85 136 180 76 12 4.5 55 37 1/2 3/4 225 AMH450 232 1 AMH550 3/4 1 259 AMH650 1 1 1/2 311 5 SeriesAMH (mm) Accessory AMH850 0: With auto drain (N.O. type) For AMH850 a: 3/88 female thread Optional Specification LL 0 T: With element service indicator 75 .