(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
Please contact us for the latest version.sales@ocaire.com, 20MM MHZ2, ACTUATOR, MHZ2 GRIPPER, PARALLEL, HT, 20MM MHZ2, 0.54066 lb, ActionModelBore size (mm)Gripping force Note 1)Opening/ Closing stroke (Both sides) (mm)Note 2) Mass (g) Gripping force per finger Effective value (N) ExternalInternalSingle actingNormally closedMHZ2-20C(N)20?5710240
IDG60M, IDG100M are fitted with AMH micro mist separator with pre-filter. 1.77 3.53 5.29 Flow Flow Flow 10 25 50 100 200 300 500 600 750 1000 110 170 240 300 100 150 75 50 Single Type 76F (60C) Dew point Single Type 40F (40C) Dew point Single Type 4F (20C) Dew point 3.53 5.29 8.02 11.3 14.12 2.72 5.44 8.29 0.44 1.09 2.19 4.41 8.83 13.24 22.07 25.6 31.78 42.02 Model Inlet Model Inlet Model
(Coil temperature: 20C, at rated voltage, without surge voltage suppressor.) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
Metric sizes 6 8 10 12 Flow rate l/min (ANR) Controlled 100 180 230 260 390 460 660 790 920 1580 1710 (free) flow Effective area mm 1.5 2.7 3.5 4 6 7 10 12 14 24 26 Note) Flow rate values are at a pressure of 0.5MPa, and temperature of 20C.
Filter plate 2 Series FN1 Flow Characteristics (Initial Value) Test fluid: Potable water Liquid temperature: 17 to 20C (room temperature) Test method: Per P/A test method (sanitary test stand) Element length 250mm: FN111-10-S Element length 500mm: FN112-10-S .1 .1 .05 .05 FN111-10-S005 (5m) Pressure loss (MPa) Pressure loss (MPa) FN112-10-S005 (5m) FN111-10-S020 (20m) .01 .01 FN112-10-S020
At circulating water temperature 20c, cooling water temperature 25c, 30l/min or less (water-cooled), and ambient temperature 32c (air-cooled)
(coil temperature 20C (68F), at rated voltage, without surge voltage suppressor) Note 2) Impact resistance: No malfunction when tested with a drop tester in the axial direction and at a right angle to the main valve and armature, one time each in both energized and deenergized states.
frequency 1kHz Green LED (stable detection) Red LED (unstable detection) Red LED (lights up when ON) Indicator light 10 to 55C Ambient temperature 25 to 70C Environmental resistance 45 to 85% RH Ambient humidity Power line: 240Vp, pulse width of 0.5s Noise resistance Temperature characteristics Voltage characteristics Detecting distance fluctuation Within +15/10% of detecting distance at 20C
(Initial value) Solenoid Specifications 24VDC 10% of rated voltage 0.55W Diode LED Rated coil voltage Allowable voltage fluctuation Power consumption Surge voltage suppressor Indicator light Response Time Note) Based on JISB8375-1981 dynamic performance test (with coil temperature of 20C and at rated voltage).
Min. bending radius (mm) 15 Note 3) Note 4) 20 35 60 95 100 130 Air, Inert gas: -20 to 200C Water: 0 to 100C (No freezing) Operating temperature 2R Material FEP (Fluorinated Ethylene Propylene Resin) At a temperature of 20C, bend the tubing into a U shape. Fix one end and gradually move the other end closer. Measure 2R at the point where the outside diameter's rate of change is 5%.
How to Calculate Flow (At an air temperature 20C) 1P1+0.1013<1.89(P2+0.1013) Q=226S P(P2+0.1013) Piping 2P1+0.10131.89(P2+0.1013) 1Completely flush (air blow) pipes before plumbing to remove dust. 2Clamping torgue: Q=113S(P1+0.1013) Q:Flow rate under standard conditions [ /min (ANR)] P1:Upstream pressure (MPa) P2:Downstream pressure(MPa) P:Pressure differential(P1-P2)(MPa) S:Effective area
(coil temperature 20C, at rated voltage, without surge voltage suppressor) When equipped with DC solenoid/surge voltage suppressor, a delay of about 20 to 30msec occurs in the OFF response time.
Port Solenoid Valve 3 Port Solenoid Valve Power Consumption (with power saving circuit) Temperature rise: 1C (with power saving circuit) V100 Specifications V100 Specifications V100 Specifications V100 Specifications Type With power saving circuit Standard Valves of specific power consumption can be manufactured to suit the f f f p f p p Power Consumption 0.1W 0.35W Temperature rise 1.0C 20C
(coil temperature 20C, at rated voltage, without surge voltage suppressor) Note 2) Impact resistance: No malfunction when tested with a drop tester in the axial direction and at a right angle to the main valve and armature, one time each in both energized and deenergized states.
2-40C) (85%) () 1 AC115V10% 60Hz (Note3) (2) 2.7A 3.0A 3.5A 6.5A 8.5A (2) 240W 260W 310W 550W 800W 15A 30mA R134a (HFC) 6.30.2oz 7.10.2oz 8.10.2oz 9.50.2oz 10.20.2oz 12.00.2oz (1805g) (2005g) (2305g) (2705g) (2905g) (3405g) N NPT3/8 NPT1/2 NPT3/4 NPT1 Rc3/8 Rc1/2 Rc3/4 Rc1 N 3/8inch 10mm 1 40lbs 18kg 55lbs 25kg 57lbs 26kg 64lbs 29kg 73lbs 33kg 110lbs 50kg 1: SCFM (ANR) 68F (20C
40mm, Double acting and Single acting available, Auto switch capable, Improved rigidity of guide rail, GRIPPER PARALLEL TYPE, ACTUATOR, MHZ2 GRIPPER, PARALLEL, HT, 20MM MHZ2, .60122 lb, ActionModelBore size (mm)Gripping force Note 1)Opening/ Closing stroke (Both sides) (mm)Note 2) Mass (g) Gripping force per finger Effective value (N) ExternalInternalSingle actingNormally closedMHZ2-20C