(Values at the initial period) Note 4) Based on JIS C 0920. Note 5) Based on JIS C 4003.
HRZ Power supply 20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) HRZD Specifications HRW Model HRS100-Wl-20-l HRS150-Wl-20-l Cooling method Water-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge kg 1.23 1.33 Control method PID control Ambient temperature Note 1) C 2 to 45 HECR HEC Circulating fluid Note 2) Tap water, 15% ethylene glycol aqueous solution, Deionized
B W FA AL T A K N N C B F M H BY S + Stroke ZZ + Stroke BW For 180, 200, 250 With rod boot BV e BZ BG BE l f h + l 4 x MA Effective thread depth MB (for holding eyebolt) ZZ1 + l + Stroke (mm) Stroke range (mm) Bore size (mm) A AL B BA BB BC BD BE BG BV BW MB BY BZ BP C D E EA F FA GA GB H K KA N M J MM MA GC 125 140 160 180 200 250 14 35 50 47 145 75 18 110 136 1/4 115 36 90 59 43 16 107
= 0.7MPa 30 30 40 50 0 40 100 200 300 0 100 200 300 400 500 Outlet air flow rate l/min (ANR) Outlet air flow rate l/min (ANR) IDG50 IDG60 0 P1 = 0.3MPa P1= 0.3MPa 0 Outlet air atmospheric pressure dew point C Outlet air atmospheric pressure dew point C 10 10 P1 = 0.5MPa P1 = 0.5MPa 20 20 P1 = 0.7MPa P1 = 0.7MPa 30 30 40 40 50 50 0 200 400 600 800 0 200 400 600 800 Outlet air flow rate l/
Solenoid Valve for 200 V, 220 VAC Specifications Manual Override Operation Warning Warning Solenoid valves with grommet and L/M type plug connector AC specifications have a built-in rectifier circuit in the pilot section to operate the DC coil. With 200 V, 220 VAC specification pilot valves, this built-in rectifier generates heat when energized.
C (D) Q2WB20050DC M18 x 190 l M18 x 200 l 190 200 C (D) Q2WB18075DC C (D) Q2WB20075DC M18 x 215 l M18 x 225 l 215 225 C (D) Q2WB180-100DC C (D) Q2WB200-100DC 7 Series CQ2 Compact Cylinder Double Acting: Single Rod Dimensions (mm) Dimensions are the same with and without auto switches. 1in = 25.4mm 180 2 x 4-31.5 depth of counter bore 26 29 29 2-Rc 1/2 (port size) Width across flats 36 40
Q = qm x C x (T2 T1) x qv x C X T 1 x 35 x 4.186 x 103 x 3.0 60 = = 60 qm x C x (T2 T1) 860 Q = = 7325 [J/s] 7325 [W] = 7.3 [kW] x qv x 60 x C x T = Cooling capacity = Considering a safety factor of 20%, 7.3 [kW] x 1.2 = 860 8.8 [kW] 1 x 35 x 60 x 1.0 x 103 x 3.0 860 = Thermo-chiller qv: Circulating fluid flow rate Q: Heat generation amount T2: Return temperature Users equipment 7325
M S C C S M C S M NI NI IN IN OUT OUT B B 2 To CYL port To CYL port 4 P.960 P.961 P.962 P.974 Connector assembly SY3000-37-80AHousing (1 set: 8 pcs.)
3000 100 3000 200 3000 110 3000 12 250 3500 125 3500 250 3500 120 3500 13 300 4000 150 4000 300 4000 130 4000 14 350 4500 175 4500 350 4500 140 4500 15 400 5000 200 5000 400 5000 150 5000 56 No.JXC-OMU0004-A 10.4 LEYLEYG LEYLEYG LEYLEYG [mm/s] 20 2] 1000 [mm/s [mm/s] 10 2] 1000 [mm/s [mm] 1 3 LEY16LEYG16 LEY25LEYG25 LEY32LEYG32 LEY40LEYG40 A B C A B C A B C A B C 14 27 51 63 126 232
(Ex.) 972A.2003 50411 (Matsuo Electric Co.,Ltd. 200VAC rating) Outline drawing [Unit: mm] Rated voltage C [ F] R [ ] Test voltage AC[V] Vinyl sheath AC[V] 18 1.5 Blue vinyl cord Red vinyl cord 200 0.5 50 Across 6 (1W) T-C 1000(1 to 5s) 10 or less 10 or less 4 15 1 10 3 10 3 31 200 48 1.5 200 or more or more Note that a diode should be installed to a DC relay, DC valve or the like.
200 H Drain discharge method Symbol Drain discharge method Note Manual valve Nil C D N.C. auto-drain N.O. auto-drain Auto-drains listed on page 17 are attached.
Auto switch model Bore size (mm) 20 25 32 40 D-M9(V) D-M9W(V) D-A9(V) BM5-020 (A set of a, b, c, d) BM5-025 (A set of a, b, c, d) BM5-032 (A set of a, b, c, d) BM5-040 (A set of a, b, c, d) REA D-M9A(V) BM5-020S (A set of b, c, d, e) BM5-025S (A set of b, c, d, e) BM5-032S (A set of b, c, d, e) BM5-040S (A set of b, c, d, e) REB Switch bracket (Resin) Transparent (Nylon) Note 1) Auto switch
C-22 VS Hastelloy C-22 H 3) Not available with SHP, SH, H materials.
200 100 0 B 800 700 600 500 400 300 200 100 0 C 800 700 600 500 400 300 200 100 0 D 800 700 600 500 400 300 200 100 0 E It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open.
D Outside diameter L1 1.5 2 2 2.5 2.5 3 1.5 2 2 2.5 2.5 3 6 6 8 8 10 10 6 6 8 8 10 10 300 300 300 300 300 300 600 600 600 600 600 600 KNL3-06-150 KNL3-06-200 KNL3-08-200 KNL3-08-250 KNL3-10-250 KNL3-10-300 KNL6-06-150 KNL6-06-200 KNL6-08-200 KNL6-08-250 KNL6-10-250 KNL6-10-300 O.D.
D E G 1 2 3 6 8 C J N R AC25C AC60 AC40A AC40C AC40D AC20A C Float type auto-drain (N.C.)
Number of axes 10 150, 200, 300 Symbol Specifications 150, 200, 300, 400, 500 15 750 1 axis XB10 Intermediate stroke (Using exclusive body) 200, 300, 400, 500, 600 20 1000 X168 Helical insert thread specifications 200, 300, 400, 500, 600, 800 25 1200 25 200, 300, 400, 500, 600, 800, 1000 2 axes 1500 32 Note 1) Stroke exceeding the standard stroke will be available upon request for special