TI/ TIL Table (2) Rated Voltage-Electrical Entry-Electrical Option Table (1) Connection Size and Applicable Model PA Insulation type Electrical entry Electrical option 1 (100 V) 2 (200 V) 3 (110 V) 4 (220 V) 7 (240 V) 8 (48 V) 5 (24 V) 6 (12 V) Class B Class H G Connection Applicable model VXD2142-03 VXD2142-04 VXD2152-06 VXD2262-10 VXD2272-32 VXD2382-40 VXD2392-50 Size PAX C D, T G, C T
Specifications ISA2-G1 ISA2-G5 ISA2-H1 ISA2-H5 Model Detection distance Fluid Operating pressure range Recommended detection nozzle 0.01 to 0.25 mm 0.03 to 0.50 mm Dry air (filtered to 5 m) 30 to 200 kPa 1.5 5 or less 8 or less 12 or less 50 to 200 kPa 2.0 10 or less 15 or less 22 or less 50 kPa 100 kPa 200 kPa Supply pressure Consumption flow rate L/min (ANR) 12 to 24 VDC 10%, Ripple (p-p
, 250, 300, 350, 400, 450, 500, 600, 700, 800 25 4000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 32 5000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 40 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 6000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 63 Note1) Contact P/A in case of a stroke length beyond the maximum.
Allowable power supply fluctuation: 3 phase 200 VAC +/-10% (50Hz); 3 phase 200 VAC to 220V +/-10% (60Hz) Power supply cable specification Prepare the power supply cables below. Power supply cable: 10AWG (5.5mm2 or greater), cable O.D.
CCT40-200 SCCS, #1 CCT63-200 SCCS, #2(#2+#13) CCT100-200 SCCS, #3(#3+#14) CCT63 SCCS, #13 CCT100 SCCS, #14 CCT100-200 SCCL, #1(#1+#12) CCT160-200 SCCL, #2(#2+#13) CCT100 SCCL, #12 CCT160 SCCL, #13 4.12-7 Air-hydro Converter Series CCT How to Order CCT 63 100 Effective oil level stroke (mm) Air-hydro converter Converter nominal size/stroke (mm) 63 100 160 50, 100, 200, 300, 400, 500
Fittings & Tubing Air Cylinders Rotary Actuators Clean series 10 11 Relief type Vacuum suction type 10 C D B M 2 B 20 100 H N M9BW C 21 C D B M 2 B 20 100 H N M9BW C Nil Built-in magnet Number of auto switches Cylinder stroke (mm) No Nil S n 2 pcs. 1 pc. "n" pcs.
IP63, JIS C 0920 Rainproof construction Except solid state switch with timer (D-M5TL, G5NTL/F7NTL/F5NTL) and magnetic resistant 2-color indication type solid state switch (D-P5DWL). D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
IP63, JIS C 0920 Rainproof construction Except solid state switch with timer (D-M5TL, G5NTL/F7NTL/F5NTL) and magnetic resistant 2-color indication type solid state switch (D-P5DWL). D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
100 100 150 150 200 200 1500 0 150 300 450 600 750 900 1050 1200 1350 1500 0 150 300 450 600 750 900 1050 1200 1350 Distance [mm] Distance [mm] 5) Supply pressure: 0.4 MPa Flow rate consumption: 316 L/min (ANR) 6) Supply pressure: 0.5 MPa Flow rate consumption: 390 L/min (ANR) 200 200 2 s 150 150 1.5 s 100 100 50 50 0.5 s 1 s 1.5 s 0.5 s 1 s 50 50 100 100 150 150 200 200 1500 0 150 300 450
T-slot 2 dimensions Compatible Motors Switch Internal Circuit D-Y7GL Motor output (W) Motor model Brake Manufacturer Power supply voltage (VAC) Motor specification symbol Controller driver model + Brown lead wire 100/110 200/220 100 200 100/115 200/230 100/115 200/230 100/115 200/230 100/115 200/230 100/115 200/230 100/115 200/230 LC1-1B1H1Without brake (Horizontal specification) 50 Main
(mm) A B C D E F G H J L Port size Bracket part no.
A C MTS D-F9W, D-M9 D-A93 D-A90, D-A96 D-M9V, D-F9WV Bore size (mm) CXSJ15 to 32 B D A 15.5 25.5 31.5 39 40 49 D 9.5 7 0 3 5 5.5 C 9.5 19.5 25.5 33 34 43 B 6 9 11 11.5 B 0.5 3 10 13 15 15.5 A 15.5 25.5 31.5 39 40 49 A 19.5 29.5 35.5 43 44 53 C 11.5 21.5 27.5 35 36 45 D 5.5 3 4 7 9 9.5 D 8 5.5 1.5 4.5 6.5 7 B 6 9 11 11.5 B 0.5 3 10 13 15 15.5 C 13.5 23.5 29.5 37 38 47 C 11 21 27 34.5 35.5
A C MTS D-F9W, D-M9 D-A93 D-A90, D-A96 D-M9V, D-F9WV Bore size (mm) CXSJ15 to 32 B D A 15.5 25.5 31.5 39 40 49 D 9.5 7 0 3 5 5.5 C 9.5 19.5 25.5 33 34 43 B 6 9 11 11.5 B 0.5 3 10 13 15 15.5 A 15.5 25.5 31.5 39 40 49 A 19.5 29.5 35.5 43 44 53 C 11.5 21.5 27.5 35 36 45 D 5.5 3 4 7 9 9.5 D 8 5.5 1.5 4.5 6.5 7 B 6 9 11 11.5 B 0.5 3 10 13 15 15.5 C 13.5 23.5 29.5 37 38 47 C 11 21 27 34.5 35.5
4 C-9 MYM50-15AK0502 GMY50 MC-16 P44 C-4 C-11.2 MYM63-15AK0503 GMY63 MC-20 P53 C-4 C-14 GMY20 GMY16 GMY25 GMY32 MYB20-15-A7164 MYB16-15-A7163 RCS-8 RCS-10 P16 P12 TMY-25 TMY-32 5.1 x 3 x 1.05 4 x 1.8 x 1.1 7.15 x 3.75 x 1.7 8.3 x 4.5 x 1.9 7 x 4 x 1.5 7 x 4 x 1.5 C-6 C-7 MYMK-20-stroke Side seal assembly Polyurethane MYMK-16-stroke MYMK-40-stroke MYMK-25-stroke MYMK-32-stroke Note) Two
T100 C IP66, AEx tb IIIC T100 C IP66 Ambient temperature ranges T6 T5 T4 ND9_E2 -40 to +60 C -40 to +75 C -40 to +85 C ND9_E2/I02 -40 to +60 C -40 to +75 C -40 to +85 C ND9_E2/I09 -25 to +60 C -25 to +75 C -25 to +85 C ND9_E2/I32 -25 to +60 C -25 to +70 C -25 to +70 C ND9_E2/D33 -40 to +60 C -40 to +75 C -40 to +82 C ND9_E2/D44 -40 to +60 C -40 to +75 C -40 to +82 C ND9_E2/I45 -25 to +60
Model A B C D E Y Y B C D A E Flat Model ZPY10D--A10 10 12 15 25 41 6 Flat with ribs U C ZPY16D--A10 ZPY10 -A10 16 18 16 26 42 7 15 12 22 1.7 10 12 1.8 3 38 ZPY13 -A10 U C 13 Dimensions by Stroke ZPY16 -A10 U C 38.5 16 18 12.5 22.5 1.2 3.5 10 16 H Model Dimensions by Stroke F G F G 10, 13 16 ZPYD10--A10 52 23 86 53 87 H Model F G F G ZPYD20--A10 62 124 63 125 51 U C U C U C U C U C ZPYD30
VCA20-12-1A 41 52 30 40 4.5 6 VCA30-12-1A 48 56 36 44 5.5 7 VCA40-12-1A 50 62 38 50 5.5 7 2 mounting screws (for mounting brackets) are included in bracket part no. 17-2-12 7 Series VCA Direct Operated 2 Port Solenoid Valve For Air Dimensions Grommet: G Conduit: C Q F D Q F 300 280 D VC G1/2 C R C R L VDW IN E E VQ Manual override A B B A 2-P Port size 2-P Port size VX2 VX Manual override
SFD100/200 AMG SFD200 only Rc 1/4 NPT 1/4 G 1/4 AFF Female thread SFD100/200 AM Different diameters for IN and OUT ports are Made to Order. For details, refer to page 326. AMD Relationship between Operating Temperature and Max.
, 300 (N) 100, 200, 300, 400, 500 15 750 1 axis Operating pressure (MPa) Piston area (mm2) 100, 200, 300, 400, 500, 600 20 Bore size (mm) 1000 0.3 0.2 0.4 0.5 0.6 0.7 100, 200, 300, 400, 500, 600, 800 25 1200 10 15 23 78 31 39 54 46 100, 200, 300, 400, 500, 600, 800, 1000 25 2 axis 15 35 52 176 70 88 123 105 1500 32 20 62 94 314 125 157 219 188 Note) Strokes are manufacturable in 1 mm increments
Maximum flow of rated flow range Pressure Loss (Reference Data) PFMC7501 (for 500 L/min) PFMC7102 (for 1000 L/min) PFMC7202 (for 2000 L/min) 50 50 50 Supply pressure 200 kPa Supply pressure 400 kPa Supply pressure 200 kPa Supply pressure 400 kPa 40 40 40 Pressure loss [kPa] Pressure loss [kPa] Pressure loss [kPa] Supply pressure 200 kPa Supply pressure 400 kPa 30 30 30 20 20 20 10 10 10