SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2B63-45DCMZ-M9BA"

Magnet: Built-in, Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 63mm, Port Thread Type: G 32-100 Bore, Stroke: 45mm, Body Option: C+M, Auto Switch Groove: Auto Switch Mounting Grooves, Mounting Bolt: -, Rod End Bracket: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Mounting Threads: -, Rod Type: -, Speed Control Type: -, Applicable Tubing: -, Suffix

Magnet: None, Mounting: Both Ends Tapped, Type: Standard, Bore Size: 40mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 45mm, Body Option: C+M, Auto Switch Groove: Auto Switch Mounting Grooves, Mounting Bolt: -, Rod End Bracket: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Mounting Threads: -, Rod Type: -, Speed Control Type: -, Applicable Tubing

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Specification: Built-in magnet, Support bracket: Through-hole

Cylinder (Tube) Inner Diameter(φ): 140, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Specification: Built-in magnet, Support bracket: Through-hole

Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Specification: Built-in magnet, Support bracket: Through-hole

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Threaded, Port thread type: Rc, Body Options: Rod End Male Thread with Rubber Bumper

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Threaded, Port thread type: Rc, Body Options: Rod End Male Thread with Rubber Bumper

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Foot, Port thread type: Rc, Body Options: Rod End Male Thread with Rubber Bumper,

Magnet: Built-in Magnet, Mounting: B [Through Hole (Standard)], Bore Size: 80mm, Thread: Rc, Stroke: 45mm, Body Option 1: Standard, Body Option 2: Male Rod End, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Through Hole [Standard], Type: Standard, Bore Size: 80mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 45mm, Body Option: C+M, Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: None, Mounting: Foot, Type: Standard, Bore Size: 63mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 45mm, Body Option: C+M, Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Both Ends Tapped, Type: Standard, Bore Size: 20mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 45mm, Body Option: C+M, Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support

Magnet: None, Rod Type: Standard, Mounting: A (Both Ends Tapped), Bore Size: 63mm, Stroke: 45mm, Body Option: CM (C+M), Auto Switch Groove: Z (Auto Switch Mounting Grooves)

Magnet: None, Rod Type: Standard, Mounting: B [Through Hole (Standard)], Bore Size: 40mm, Stroke: 45mm, Body Option: CM (C+M), Auto Switch Groove: Z (Auto Switch Mounting Grooves)

Magnet: D (Built-in), Mounting: F (Front Flange), Type: Standard, Bore Size: 100mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 45mm, Body Option: CM (C+M), Auto Switch Groove: Z (Auto Switch Mounting Grooves)

Magnet: D (Built-in), Rod Type: Standard, Mounting: B [Through Hole (Standard)], Bore Size: 20mm, Stroke: 45mm, Body Option: CM (C+M), Auto Switch Groove: Z (Auto Switch Mounting Grooves)

Applicable auto switch Description Size Quantity BBA4 Auto switch mounting screw M3 x 0.5 x 15 L 1 BJ2-008S, BJ2-010S, BJ2-012S, BJ2-016S D-C7, C8 D-H7 BM2-020AS, BM2-025AS, BM2-03AS, BM2-040AS 112 C85/C75 Series Rail Mounting Type Mounting Bracket Solid state D-M9N(V), D-M9P(V), D-M9B(V), D-M9NW(V), D-M9PW(V), D-M9BW(V), D-M9NA(V), D-M9PA(V), D-M9BA(V) Reed D-A90

For details, refer to pages 443 and 445. 273 CHKD Series How to Mount and Move the Auto Switch Solid state D-Y59 , D-Y69 , D-Y7P(V) D-Y7NW(V), D-Y7PW(V), D-Y7BW(V) D-Y7BA Reed D-Z73, D-Z76, D-Z80 Solid state D-M9N(V), D-M9P(V), D-M9B(V), D-M9NW(V), D-M9PW(V), D-M9BW(V) D-M9NA(V), D-M9PA(V), D-M9BA(V) Reed D-A90(V), D-A93(V), D-A96(V) A