74 637 A VND Series Port size: 32A, 40A, 50A H (Valve open) Indicator (Option) Pilot port 12(P1), 10(P2) Port size: refer to table below P1 P2 F G E A 32 B D J Main port 1(A) (Back side 2(B)) C A B Port size: refer to table below Main port 1(A), 2(B) Pilot port 12(P1), 10(P2) A B C D E F G H J Model VND50D-32A VND60D-40A VND70D-50A 1 8 1 4 1 4 1 4 1 2 1 1 2 105 120 140 77 96 113 53 60 74
C [dm3/(sbar)] b Cv C [dm3/(sbar)] b Cv VP517Y G3/8 8.8 0.14 2 8.2 0.15 1.8 VP717Y G1/2 13.8 0.11 2.9 12.9 0.18 2.9 2 VP500/700 Series Spacer Center of F.R.L. body D C B Model A B C D Y300-A 4.2 43.4 21.7 57.9 Y400-A 5.2 53 26.5 68.5 A (Spacer width) Seal Y400-A Spacer with Bracket D K Center of F.R.L. body J H F G E E C B Seal A (Spacer width) Y400T-A Model A B C D E F G H J K Y300T-A 4.2
0.5 0.6 0.7 F 200 V Black COM (0 V) G Shield Data A phase output pulse Connector pin arrangement B phase output pulse G A F B H E D C 0 1 2 3 4 3 2 1 Counter value 10-12-55
Decimal display Hexadecimal display 10 A 11 b 12 c 13 d 14 E 15 F Note 4) Applicable to non-magnetizing lock 47 Programless Controller (With Stroke Study) Series LECP2 LEMB LECP2 LECP1 LECP6 LEC-G LEMC LEMH/HT Model Selection Specific Product Precautions Controller Details e r No. Display Details Description t Power supply ON/Servo ON : Green turns on.
Lube Unit/ALDU600-06 to 10, ALDU900-12 to 20 Float switch mounting position Mounting thread M12 R 3.2 S 40 Q IN P M N M L A B C E E F G K J (Bracket mounting dimensions) H D S Bracket (Option) Panel (Option) 6 x 17 A B C D E F G H J K L M N P Q R S Model Port size ALDU600-06 ALDU600-10 ALDU900-12 ALDU900-14 ALDU900-20 289 291.2 453 453 476 24.5 13.6 51 45.5 14.5 69.5 78.2 89 94.5 102.5 4
This lowers the pressure in the diaphragm chamber q and the force generated by the pressure regulator spring e pushes down the diaphragm.
This lowers the pressure in the diaphragm chamber q and the force generated by the pressure regulator spring e pushes down the diaphragm.
Plug (Prepared by customer) L N E [Accessory] Power supply connector N E Earth leakage breaker (Secondary side) L N Cable Crimped terminal (Prepared by customer) E (Earth) L Cable size : 14AWG Wire tightening torque : 0.5Nm Fig. 3-5 Power supply cable 3.3 Installation HRS Series 3-10 HRX-OM-M090 Chapter 3 Transport and Setting Up Wiring 1.
signal power supply 24V 13 CAL 14 E-STOP *1 *1 When the air servo cylinder is operated, turn ON the E-STOP signal.
The end angular speed is obtained by: t Table 9 Allowable kinetic energy (J) Size Allowable kinetic energy : Rotation angle [ rad ] : Rotation time [ s ] 1 0.001 Kinetic energy E is obtained by: 2 0.0015 3 0.002 7 0.006 E Therefore, the rotary table rotation time is: E: Allowable kinetic energy [ J ] : Rotation range [ rad ] I: Moment of inertia [ kgm2 ] During uniform acceleration, the
e. f. -37- 6.5 (LEFBLEFS -(A) (-(B)) A B LEF16 M2.5x5 LEF16 M2.5x16 LEF25 M3x6 LEF25 M3x20 LEF32 M3x6 LEF32 M4x30 LEFS40 M3x6 LEFS40 M4x35 -38- 7. No. 1) 1 / /P30 4.
ID Construction IDG SFD101-02 SFD102-02 IDK w q r t e q r e w AMG AFF AM AMD AMH Component Parts Component Parts No. Description Note Material Aluminum alloy No.
Stainless steel Aluminum die-casted Material Note Spool/Sleeve Body Platinum silver w e Sub-plate 02 03 Aluminum die-casted Platinum silver Sub-plate Assembly Part No.: VS3110-SReplacement Parts Mounting bolts and gaskets are not attached. Part no. VS3115-G Description Material No.
f g Nil Reed switch L R Solid state switch S h Nil L R S Operating direction Left Right a b h g d c f e Note) Lead wire length symbols 0.5m .
For manifold type 31, S31, 32, S32 Body option 5 port 0: Pilot valve individual exhaust for the pilot valve 3: Common exhaust type for main and pilot valve (With gasket and screws) D: Push-turn locking slotted type M5: With M5 port sub-plate For sub-plate, manifold type 41, S41, 46, S46 R port P, E port R port P, E port Electrical entry 24, 12, 6, 5, 3 VDC 100,110, 200, 220 VAC 24, 12, 6,
Seal type Nil E With Without light, with surge voltage suppressor Metal seal Rubber seal 0 1 Coil voltage 1 2 3 Stations Function D side U side 1 2 3 4 5 6 100VAC (50/60Hz) 200VAC (50/60Hz) 110VAC (50/60Hz) 220VAC (50/60Hz) 24VDC 12VDC Standard type (1W) Energy saving type (0.5W) External pilot Nil Y Note 1) R Note 2) Note 1) Applicable to DC specifications.
bracket) are included with the above parts. 3 Series VCB Direct Operated 2 Port for Heated Water Dimensions (mm) 1in = 25.4mm Grommet: G Conduit: C Q Approx. 300 F D Approx. 280 D Q F C G1/2 C R R E E B A H 2-P Port size 2-P A 2-M Thread depth N B H Port size 2-M Thread depth N L L K K Conduit terminal: T F (Q) 34 25 U R C G1/2 E B A H D 2-P Port size (S) 2-M Thread depth N L K (mm) Electrical
GB WB W QB RSH MIW MIS A (mm) Circumscribed circle O QA Model Stroke A B CD CT CZ D E FT FX FZ GA GB H L N 212.5 QB 8 RS2H50 RS2H63 RS2H80 30 84.5 20 8 36 32 64 20 73 93 16 16 128 85 44 9 14 depth 5 10 30 234.5 90 20 10 45 40 77 25 90 114 24 24 144.5 103 53 11 18 depth 6 12.5 8.5 40 292.5 121 25 10 45 50 98 25 110 138 24 35 171.5 132 54.5 13 20 depth 6 12.5 10 P (Piping port) Model Stroke
ZS-26-E-4 R04 4 plug-in reducer Connector for PSE300 1 pc.
e E , q 1.5 8 1 2 1 6 2 0 Cylinder speed (in/sec.) Sl6ct a propr unit sccording to exhaust flo/, in lh6 following ordr: (l) Oete|mine air con6umplion ot actuaicrs uaed in tl|e ckc\rii.