Cv b Cv 1 2 (P A) 2 3 (A R) Model Flow characteristics Note) Type of actuation Port size Weight (g) Base mounted VZ512 VZ522 VZ514 VZ524 VZ514 VZ524 N.C.
(mm) H1 6 7 8 11 11 H 36 40 45 53 56 GY 5 5.5 7 8 10 GX 10 8.5 9 11.5 11.5 EY 26 42 54 64 72 D 12 14 16 20 20 B1 17 19 22 27 27 C 54 68 86 104 124 B 24 28 32 39 50 BY 7 8 9 9 12 AL 19.5 23.5 27 32 32 BX 9 6.5 8 10 11 ET A 22 26 30 35 35 BS 42 50 54 64 63 K 5.5 5.5 6 7 7 BT Model MUB25 MUB32 MUB40 MUB50 MUB63 Standard stroke (mm) 5, 10 5, 10 5, 10, 15, 20 5, 10, 15, 20 5, 10, 15, 20 M5 x 0.8
(mm) H1 6 7 8 11 11 H 36 40 45 53 56 GY 5 5.5 7 8 10 GX 10 8.5 9 11.5 11.5 EY 26 42 54 64 72 D 12 14 16 20 20 B1 17 19 22 27 27 C 54 68 86 104 124 B 24 28 32 39 50 BY 7 8 9 9 12 AL 19.5 23.5 27 32 32 BX 9 6.5 8 10 11 ET A 22 26 30 35 35 BS 42 50 54 64 63 K 5.5 5.5 6 7 7 BT Model MUB25 MUB32 MUB40 MUB50 MUB63 Standard stroke (mm) 5, 10 5, 10 5, 10, 15, 20 5, 10, 15, 20 5, 10, 15, 20 M5 x 0.8
C Y Y B G A 90 B 90 B G A D Note 1) 90 G A H X X X D Note 1) D Note 1) B B B F E F F E A H A G G RG RT RS B 296 305 C R310 R445 D 93 129 E 60 87 F 10 15 G 6 7 B 296 309 C R390 R495 D 93 129 E 60 87 F 10 15 G 6 7 B 299 307 C R350 R440 D 93 129 F 10 15 G 6 7 H 610 700 A 600 743 A 680 797 A 643 740 15 32 15 32 15 32 Y Note 2) Y Note 2) Y Note 2) X 558 to 573 685 to 708 X 518 to 533 558 to 581
At this time, magnet B goes out of the movement range of switch B, causing switch B to turn OFF . Furthermore, the piston moves to the right, causing magnet A to enter the movement range of switch A. As a result, switch A turns ON.
B C L A B C Lead 20 10 5 2.86 20 10 5 Parameter *1,*2 Para.
At this time, magnet B goes out of the movement range of switch B, causing switch B to turn OFF . Furthermore, the piston moves to the right, causing magnet A to enter the movement range of switch A. As a result, switch A turns ON.
FLUID OUT) Pump chamber B Pump chamber A Check valve Shaft Suction port (FLUID IN) Diaphragm B Diaphragm A Drive chamber A Drive chamber B Control unit 1.
Avoid especially the application of pressure above specifications through a water hammer.
Allowable Kinetic Energy Extension locking direction Retraction locking direction 100 100 50 50 Load weight kg Load weight kg 10 10 50 W 50 5 5 40 40 B 32 32 0.5MPa 0.4MPa 0.5MPa 0.4MPa A A 25 25 1 1 100 500 100 500 B W Maximum speed mm/s Maximum speed mm/s B: Retraction locking direction F: Extension locking direction 9-13-4 4 Series MLU Specific Product Precautions 2 Be sure to read before
CHKGB Bore size Rod end thread type Auto switch Quantity XC64 Stroke With air release valve Dimensions CH KGB--XC64 A C C B A B C Bore size (mm) 20 16.5 9.5 7 25 17 10 8 32 19.5 17 10 40 21.5 18.5 10 50 24 21.5 10 63 27.5 24 10 80 31 27.5 15 100 36 33 15 Note) Dimensions other than those highlighted above are standard. 24
to 90 CKZT80-A015B 30 to 90 80 CKZ80-42 3680N-R A B C 30 to 105 CKZ80-42 3680N-R D E F 30 to 105 For mounting bolt, a hexagon socket head cap screw and a spring washer No. 2 are recommended.
Pin description 1 DC(+) 2 NC/Analog output A (44.2) 3 DC() 4 OUT (mm) A B Output specification Output for monitor unit only 42 62 Output for monitor unit + Analog output 52 72 Flow direction 309 B Series PF2W Dimensions: Remote Type Sensor Unit For Water PF2W511-(N)B 148 32 80 70 58 46 45 36 2 x Port size 45 2 4 x 5.5 (44.2) A (mm) A B Output specifications Output for monitor unit only 63
B B A B B 45 45 2 x 10-32 UNF depth 0.25 (6.3) (Mounting hole) 2 x 10-32 UNF depth 0.25 (6.3) (Mounting hole) 1.0 (25.4) 1.0 (25.4) AP3650 AP3657 1.88 (47.8) 0.44 (11.2) 3.02 (76.7) 0.13 (3.3) 0.4 (10.2) 1.87 (47.5) A B B 0.44 (11.2) 3.6 (91.4) 45 1.0 (25.4) 2 x 10-32 UNF depth 0.25 (6.3) (Mounting hole) A B B Connections A B inch inch (mm) (mm) FV4 MV4 TW4 FV6 MV6 TW6 FV4 MV4 TW4 FV6 MV6
How to Order Sound Absorbing Material Assembly A SE1 ZL112A ZL112A SC1 A Sound absorbing material 2 Sound absorbing material 1 Silencer case assembly Sound absorbing material assembly * Sound absorbing material 1 and 2, 1 pc. each/set (Including sound material assembly and a clip) b How to Order Port Block Assembly 0 How to Order Adapter Assembly for Bottom Mounting ZL112A EP1 A A AD1 ZL112A
Power supply 24 VDC B B B Ground with a ground resistance of 100 or less without connecting the DC1 () lead (Blue) of the power supply cable to the power supply 0 V. Red A A +24 V Black Blue Charged object Charged object 0 V Reduced-wiring Fieldbus System F.G. (mm) Ground with a ground resistance of 100 or less. A B When using the autobalance sensor (body-mounting type) 10 20 20 40 3.
C D 15, 20 (mm) Applicable switch model Bore size (mm) D-A9 D-F9, D-A9W A B C D A B C D 15 56.5 17.5 76.5 21.5 72.5 60.5 87.5 67.5 20 39.5 19.5 23.5 83.5 35.5 71.5 Note 1) Auto switches cannot be installed in Area C in the case of 15.
signal 26 OUT (B contact) The error signal turns OFF when a high voltage alarm or output signal over current is generated.
(A contact) or N.C. (B contact). Contact output signal 2 FLT alarm selects N.O. (A contact) or N.C. (B contact). Contact output signal 3 WRN alarm selects N.O. (A contact) or N.C. (B contact). (1) (2) (3) Setting of contact output signal 1 to 3 Table 5.4-27 Setting of contact output signal 1 to 3 No.
P_1 = A-(A-B)/4 A = Maximum pressure value H_1 = | (A-B)/2| B = Minimum pressure value To clear the stored auto-preset settings, press the and buttons simultaneously for 1 second or longer. -29No.TQ0010298-OM003-B [F 6] Fine adjustment of display value This function is used to manually perform fine adjustment of the displayed pressure. It is adjustable within the range 5% R.D.