B MY CY 22 (20) MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A CX D-A9V D-M9V D-F9WV D-X 20( ): Denotes the values of D-M9V, D-F9WV. 5(7) B W Data D-A9, D-A9V D-F9W, D-M9 D-F9WV, D-M9V Bore size (mm) A A W B W B A W B 6 12.5 3.5 (6) 16.5 7.5 2.5 16.5 5.5 2.5
200 300 400 Flow rate (slpm, N2) AK1000 100 psig (0.69 MPa) 40 psig (0.28 MPa) Inlet pressure: 80 psig (0.55 MPa) 20 psig (0.14 MPa) 1.50 (38.1) 50 0.34 2.25 (57.2) 40 0.28 Delivery pressure (MPa) Delivery pressure (psig) 30 0.21 0.69 (17.5) 2.00 (50.8) 20 0.14 10 0.07 0.88 (22.4) 2 x 10-32 UNF depth 0.25 (6.3) (Mounting hole) 0 0.00 0 20 40 60 80 Flow rate (slpm, N2) AK1000HF 100 psig (
Applicable bore Shock absorber model ML1-A25H ML1-A32H ML1-A40H ML1C25 ML1C32 ML1C40 101 90 25 20 11 72 67.3 12 31 39.5 Max. 16.5 4.5 3 RB1412 120 107 30 25 16 93 73.2 15 38 49 Max. 20 5.5 6 RB2015 147 129 30 31 16 105.5 73.2 15 40.5 54.5 Max. 25 5.5 6 Side Support Side support A 2 x G E E F 2 x H A B Side support B 2 x J A B (mm) A B C D E F G H J Part no.
AXT100-20-2-05 AXT100-20-2-06 AXT100-20-2-01 AXT100-20-2-02 AXT100-20-2-03 AXT100-20-2-04 Clip Circuit with light PR plate qChanging the piping direction from in-line to perpendicular (port on the valve) is possible on the VQZ100 series. Follow the steps below to change piping direction: Remove the fitting clips that hold the fitting and port plug in place.
MY1CW16/20 MY1MW16/20 B A Reed Switch Solid State Switch D-A90(V), D-A93(V), D-A96(V) (mm) D-M9N(V), D-M9P(V), D-M9B(V) D-F9NW(V), D-F9PW(V), D-F9BW(V) 16 20 Mounting position Mounting position 16 20 A A B B Operating range Note) Operating range Note) Solid State Switch Reed Switch 24 Series MY1W Mounting of Auto Switch & Installation of Lead Wire Cover (50, 63) Caution Be sure to install
MXW A 16 12 X11 Change of adjuster assembly Option (-X11) Standard Changing the stroke adjustment range from 5 mm to 15 mm for one side A Replace W/o shock absorber 2 Applicable bore size (mm) Nil X11 Replace A B With shock absorber Adjustment range 4 5 mm 15 mm Standard Option MXW8 MXW12 MXW16 MXW20 MXW25 8 12 16 20 25 Changing to the one with shock absorber Add B 2 A B Replace Add Changing
Double acting PA PA B A PB B A With by-pass Suck back valve Manual Operation-Series LVH N.C. Double acting P PA PA Locking and non-locking types available B A B A PB B A Integral fitting type/Threaded type Manifolds Main applications and fields For shut off For air bleeding N.C.
Tightening torque 70D 12.5Nm 80D 24.5Nm 90D 24.5Nm -20- Doc. no. AMX-OMU0058-C 7-3. Element replacement A) Remove the bowl from the body [See Auto drain replacement C) to D)]. B) Remove the element and used O-ring. At this time, remove the support ring for easier removal. C) Insert an element (new) into the bowl and mount an O-ring (new) for the bowl.
35 1 5 9.5 20 1 3.3 22.5 38 9 17 11 A B 13 6 8 Note) NPT thread for AN101 and AN110 is alsoavailable.
Do not use One-touch fittings in an environment where the air catch sensor is exposed to water or other liquid. 16-8-19 20 Series ISA2 Specific Product Precautions 2 Be sure to read before handling. 2 Port Solenoid Valve Series VCA Wiring Disassembly and Assembly Caution Caution DIN connector (B type only) The internal wiring of the DIN connector is illustrated below.
) 32 32 25 25 0.1 0.1 20 20 15 15 10 10 0.01 0.01 0 0 20 40 100 60 80 20 40 100 60 80 Overhang L (mm) Overhang L (mm) CXSJM CXSJL Graph V = over 400 mm/s; up to 50 mm stroke 13 CXSJM CXSJL Graph V = up to 400 mm/s; up to 50 mm stroke 12 1 1 Weight m (kg) Weight m (kg) 32 32 0.1 0.1 25 25 20 20 15 15 10 10 0.01 0 20 40 100 60 80 0.01 0 20 40 100 60 80 Overhang L (mm) Overhang L (mm) 5 Compact
Never use in an atmosphere of explosive gases. The structure of switches is not intended to prevent explosion. Never use in an atmosphere with an explosive gas since this may cause a serious explosion. 2. Mount switches in locations without vibration (98m/s or less) or impact (490m/s or less). 3. Do not use in an area where surges are generated.
Hole Switch holder B Switch holder A Switch guide Switch case Figure 2 Solid state switch First groove MRHQ 20, 25 D-F9 3. Secure the switch at an appropriate position with a flat head watchmakers screwdriver as indicated in Figure 3. Tightening torque: 0.05 to 0.1 Nm Second groove MRHQ 10, 16 3.
Nil S n L Auto switch type Nil Without auto switch Cylinder bore size (stroke mm) Refer to the table below for auto switch part numbers. 6 8 12 16 20 25 10, 20, 30, 40, 50 10, 20, 30, 40, 50, 75 10, 20, 30, 40, 50, 75, 100 10, 20, 30, 40, 50, 75, 100, 125 10, 20, 30, 40, 50, 75, 100, 125, 150 10, 20, 30, 40, 50, 75, 100, 125, 150 Functional option Nil F R Note 2) Standard With buffer With
Hs B 30 (33) 36 Auto switch Numbers in ( ) are for type D-F5LF. Approx. Hs D-A44 D-A5/A6 D-A59W 33 Auto switch A Auto switch A B 34.5 Approx. Ht Approx. Ht 56 36 Approx. Hs B Approx.
Note 2) The figure shows an extended piston rod. 7 Heavy Duty Stopper Cylinder Series RSH/RS1H Auto Switch Proper Mounting Position Auto switch B A Auto switch proper mounting position D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W Auto switch models D-Y69 D-Y7PV D-Y7WV D-Y7BAL Bore size (mm) A B A B A B 20 8(6.5) 18 18 9.5 18 2 32 10.5(9) 13.5 13.5 12 13.5 4.5 50 12(10.5) 22 22 13.5 22 6 63 15.5(14) 24.5
Solenoid Specifications Apparent power (VA) Inrush Holding Power consumption (W) (Holding) Temperature rise (C ) (Rated voltage) Frequency (Hz) 50 25 12 60 20 8 Model Power source 5 50 3.5 35 6 50 8 55 6.5 45 8 50 0.5 60 9.5 50 11.5 55 Note) They are values in an ambient temperature of 20C 5C and application of rated voltage.
Features 2 Model Selection 1 Obtain the correction factor for the temperature from data A or B and the correction factor for the air pressure from data C. Temperature Data A or B = Series IDU: Data A IDF1D to 240D: Data B-1 IDF 370B: Data B-2 Air pressure Data C = Series IDU and Series IDF: Data C 2 Calculate corrected air flow by using A or B and C.