dew point) C -20 -10 0 10 20 30 40 50 60 0 10 20 30 40 50 60 70 80 [Example] If air at 30C and 60% humidity is pressurized to 0.7MPa, the dew point of the air will be 62C. ( ) If this is cooled to 25C, the amount of condensed water generated will be 15.2g/m3. ( ) Therefore, with an air flow rate of 3m3/min (22kW equivalent compressor), the amount of condensed water per unit of time is 15.2
This information is needed when contacting an SMC sales distributor. Model number Serial number 41A Kind and amount of refrigerant 315 * (An example of "HRL300-A-20" model.) "3~" stands for "3 inter phase".
width across flats 3 E D C 3 2 A B Stroke: 20 to 50 mm Dimensions: 10 mm Stroke A (mm) B C D E F H I J Model ZPR20F10-0-A14 20 22 12.5 15.5 29.3 58.5 46.5 126.5 ZPR25F10-0-A14 25 28 50 ZPR32F10-0-A14 13 16 29.8 59 47 32 35 127 Additional Dimensions by Stroke (mm) (mm) Q: 6 Q: 8 Model H I J R S R S Stroke ZPR20F10-0-A14 20 +10 3 0 ZPR25F10-0-A14 30 +20 +7 12.8 24.3 15.2 26.2 ZPR32F10-0-A14
to 10 m between an EXW1-series Base and an EX600-W-series Remote. *3 The settings and monitor function are restricted when EX600-WEN/WPN and EXW1-R# are used in combination. *4 For combinations involving EX600-W series, refer to the operation manual for the product in use.
A A afll-'h s-zl;lh P R P R (external pilot type) A A , A;Tt-Zb gzt;]ri! , P R P R Model Specifications Air and inert 20-100 PSI (1.5"7kgf/cm,) VAC-1 10Torr 20-1OoPS|(15-7ksflcm'?) N,lax. 120'F (50'C) 20 ms or less (7OPS|) 600 cpm , Slotted Knob locking type Individual, Common Not (Use turbine oil # 1 (lSO VG32) if lubrication is Drovided.)
LEKFS25(L/R)/Ball Screw Drive Horizontal Vertical 20 30 Lead 6: LEKFS25(L/R)EB Lead 6: LEKFS25(L/R)EB 25 15 Work load: W [kg] Work load: W [kg] 20 Lead 12: LEKFS25(L/R)EA 10 15 Lead 12: LEKFS25(L/R)EA 10 Lead 20: LEKFS25(L/R)EH 5 Lead 20: LEKFS25(L/R)EH 5 0 0 0 100 200 300 400 500 600 0 200 400 600 800 1000 1200 Speed: V [mm/s] Speed: V [mm/s] LEKFS32(L/R)/Ball Screw Drive Horizontal Vertical
r r r q w e OUT side passage IN side passage y u t OUT IN i o Basic type (Knob): IR30l0-A e e r q r w e OUT side passage IN side passage t u OUT IN o i Basic type (Knob): IR30l1 2-A e e r q r w e OUT side passage IN side passage t u OUT IN o i 800 Precision Regulator IR1000-A/2000-A/3000-A Series Dimensions Basic type (Knob): IR10l0-01l-A 10.5 42 ARJ 1.6 Bracket AR425 to 935 Mounting hole
This information is needed when contacting an SMC sales distributor. (It is an example of model "HRS040-A-20".)
This information is needed when contacting an SMC sales distributor. THERMO CHILLER HRS050-A-20 POWER SUPPLY SERIAL No.
speed (mm/s) 20 1 50 100 150 200 0 Stroke + Eccentric distance (mm) Refer to Model Selection in Best Pneumatics catalog Vol. 6/7 for details about model selection procedure. 3 ISO Standards [ISO/21287] Compact Cylinder Series C55 Construction 20, 25 With auto switch (Built-in magnet) w u i t r !
6)*1 55 + 35 (n 2) (n = 2, 3, 4, 5) D-M9mA 25 25 40 25 + 35 (n 2) 2 (n = 2, 4, 6)*1 60 + 35 (n 2) (n = 2, 3, 4, 5) D-M9mV 25 25 35 20 + 35 (n 2) 2 (n = 2, 4, 6)*1 35 + 35 (n 2) (n = 2, 3, 4, 5) D-M9mWV D-M9mAV 25 25 35 20 + 35 (n 2) 2 (n = 2, 4, 6)*1 35 + 35 (n 2) (n = 2, 3, 4, 5) *1 When n is an odd number, an even number that is one larger than the odd number is to be used for the
to 760 10 to 300 701800 Note2) Stroke 30 to 930 20 to 620 10 to 300 801900 Speed range [mm/s] 30 to 780 20 to 520 10 to 250 9011000 30 to 660 20 to 440 10 to 220 10011100 Actuator specification 30 to 570 20 to 380 10 to 190 11011200 20 to 500 30 to 500 10 to 250 1000 Driver type LECPA Note2) Stroke 30 to 500 20 to 440 10 to 220 Speed 10011100 range [mm/s] 30 to 500 20 to 380 10 to 190 11011200
A1 L1 R1 U1 NDH10 E1 MM NX Applicable bore size (mm) I-020B I-032B I-04A IA-04 A B C D E F M R Size Tolerance Note +0.027 0 +0.027 0 +0.027 0 +0.027 0 +0.058 0 +0.058 0 +0.070 0 +0.070 0 0.1 0.2 0.1 0.2 0.1 0.3 0.1 0.3 AD-FI-20 AD-FI-25 AD-FI-32 AD-FI-40 9 9 16 16 16 18 22 22 36 38 55 55 9 9 12 12 10 10 15.5 15.5 20 25 32 40 20 20 24 24 14 14 20 20 30 10 16 22 60 20 25 32 40 46 28 M8 x 1.25
, 521 50 20 40 Pressure loss (kPa) Pressure loss (kPa) 15 30 10 20 5 10 0 200 0 50 100 150200250 300 400 350 450 500 20 50 100 150 Flow rate (l/min) Flow rate (l/min) Sensor Unit Construction PF2A710/750 PF2A510/550 q w e r w t w e Parts list No. 1 2 3 4 5 Description Attachment Seal Mesh Body Sensor Material ADC NBR Stainless steel PBT PBT Flow direction PF2A711/721/751 PF2A511/521/551 Parts
19 20 19 20 19 20 19 20 19 20 19 20 19 20 COM (Based on IEC529) Station 1 Double wiring Station 2 Single wiring Station 3 Double wiring Station 4 Single wiring (Refer to the connector wiring diagram.)
LVA LVH A R P 3 port N.C. PA LVD N.C.
(Refer to 2.3.1 Setting of contact input signal type and form) If an input from an external switch is detected, it can be generated as an alarm.Options to select continuous monitoring or monitoring during operation are available. Also, the detection start time after the start of operation and the detection end time can be set.
(mm) LVQ0-S Dimensions (N.C. valve) A B C D E F G H J K L M N P Q R Model LVQ20-S LVQ30-S LVQ40-S LVQ50-S LVQ60-S 25.5 46 31.5 58 33.6 56.5 12 77 21.8 37 5 7 15 31.3 21 25.3 23.5 47 29.5 59 45.4 77 16.5 95 32 50 6 7 20 37.2 25 31.2 23.5 47 29.5 59 45.4 82.5 22 109 37.5 55.5 6 7 20 37.2 25 31.2 35 70 41 82 75 127 25 141 50.2 78.2 10 7 20 50.8 38.5 45 35 70 41 82 75 137 32 150 60 88 10 7 20
Perform an echo back test for the controller with controller ID:1.
110 130 180 Q 26 28 28 34 34 50 50 60 76 R 4.5 5 5 5 5 9 9 10 12 S 1.6 2.0 2.0 2.3 2.3 3.2 3.2 4.5 4.5 T U 37 37 37 37 37 37 37 37 37 1/8, 1/4, 3/8 1/4, 3/8 1/2 3/8, 1/2 3/4 1/2, 3/4 1 3/4, 1 1, 11/2 159 172 178 204 210 225 232 259 311 13 13 16 16 19 19 22 22 32 100 113 119 145 151 166 173 200 253 63 76 76 90 90 106 106 122 160 20 20 20 20 20 20 20 20 20 63 76 76 90 90 106 106 122 160 24