Nil s n A 12mm 32 32 Bore size 32 40 50 63 32mm 40mm 50mm 63mm 40, 50, 63 A B 16.5mm 19.5mm 40, 50, 63 50, 63 Nil Without auto switch (built-in magnet) Auto switch type 40 is only available with A:16.5mm clevis width. Select applicable auto switch models from the table below. Cylinder stroke (mm) 32, 40, 50, 63 50, 75, 100, 125, 150 Built-in magnet cylinder part nos.

INLET (Upstream) is defined as a port connected to the region below the valve seat. It is illustrated with an arrow pointing towards the valve body or an "empty" triangle on the schematic. OUTLET (Downstream) is defined as a port connected to the region above the seat and below the diaphragm.

Hexagon socket head cap screw MYMK-16-A MYMK-16-A MYMK-25-A MYMK-25-A MYMK-25-A Side seal unit Nickel plated Seal List No. !

Precautions Plug a connector in or out vertically, never at an angle. Applicable cable O.D.: 3.5 to 7 (Reference) 0.5 mm2 2 core and 3 core wires equivalent to JIS C 3306.

Do not If using the product in an interlocking circuit Provide a double interlocking system, for example a mechanical system. Check the product regularly for proper operation. Otherwise malfunction can result, causing an accident.

Install an air filter close to the valve on the upstream side. A filtration size of 5 m or smaller should be selected. 3) Install an aftercooler or air dryer, if necessary. Compressed air that contains excessive drainage may cause the malfunction of the valve or other pneumatic equipment. To prevent this, install an aftercooler, air dryer, etc. 2.

Install a deceleration circuit to reduce the speed before cushioning, or install an external shock absorber to relieve the impact. In this case, the rigidity of the machinery should also be examined. 5) Consider a possible drop in operating pressure due to a power outage, etc.

(Default setting: 0 s) 0.00 s 0.05 to 0.1 s (increment of 0.01 s) 0.1 to 1.0 s (increment of 0.1 s) 1 to 10 s (increment of 1 s) 20 s 30 s 40 s 50 s 60 s Setting of security code The user can select whether a security code must be entered to release the key lock. At a time of shipment from the factory, it is set such that a security code is not required.

Note 2) The figure shows an extended piston rod. 7 Heavy Duty Stopper Cylinder Series RSH/RS1H Auto Switch Proper Mounting Position Auto switch B A Auto switch proper mounting position D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W Auto switch models D-Y69 D-Y7PV D-Y7WV D-Y7BAL Bore size (mm) A B A B A B 20 8(6.5) 18 18 9.5 18 2 32 10.5(9) 13.5 13.5 12 13.5 4.5 50 12(10.5) 22 22 13.5 22 6 63 15.5(14) 24.5

P T 21.5 27.5 A I R R G Y 7 R A I 8 17.5 32 8 42 Side A Side B Scale: 40% 12 Rotary Gripper Series MRHQ Construction Description Material Note Parts list No.

B 0.2 A 0.2 Bore size [mm] A [mm] B [mm] Hexagon socket head cap screw 12 (10 x 2) 52 11 M3 x 0.5 16 (12 x 2) 57 11 M4 x 0.7 20 (16 x 2) 75 14 M4 x 0.7 25 (20 x 2) 84 17 M5 x 0.8 32 (25 x 2) 98 21 M6 x 1.0 40 (32 x 2) 107 27 M8 x 1.25 50 (40 x 2) 135 37 M8 x 1.25 63 (45 x 2) 146 40 M10 x 1.5 80 (56 x 2) 184 50 M12 x 1.75 100 (71 x 2) 219 62 M14 x 2 7.

A model should be selected with a gripping force of 7 to 14 times that of the workpiece mass. If high acceleration, deceleration or impact forces are encountered during motion, a further margin of safety should be considered.

Water Hammer Relieving Characteristics (VXR2150/2152/2260/2262) Water hammer (Example) Series VXR2 prevents damage of piping, equipment and system and generation of vibration through a great relieving of a water hammer generated using an ordinary solenoid valve.

Install an air filter near this product on the supply side. Select a filtration degree of 5m or less. 2. Compressed air containing a large amount of drainage can cause malfunction of this product and other pneumatic equipment. As a countermeasure, install an after-cooler, air dryer or water separator, etc. 3.

A B C A B A B A B A B 15A 20A 25A Note 1) For each piping diameter for each body size, the second and later numbers or symbols indicate reducing.

A C D-F9 D-F9W D-M9 D-A93 D-A90 D-A96 D-F9V D-F9WV Bore size (mm) CXSJ15 to 32 B D A 15.5 25.5 31.5 39 40 49 D 9.5 7 0 3 5 5.5 C 9.5 19.5 25.5 33 34 43 B 6 9 11 11.5 B 0.5 3 10 13 15 15.5 D 7.5 5 2 5 7 7.5 A 15.5 25.5 31.5 39 40 49 A 19.5 29.5 35.5 43 44 53 C 11.5 21.5 27.5 35 36 45 D 5.5 3 4 7 9 9.5 D 8 5.5 1.5 4.5 6.5 7 B 6 9 11 11.5 B 0.5 3 10 13 15 15.5 C 13.5 23.5 29.5 37 38

If the body is held while tightening bolts etc., the guide section will be subjected to a large moment, and there may be a loss of precision. For connection with a load having an external support/guide mechanism, select an appropriate connection method and perform careful alignment.

Doing so may cause human injury and/or an accident. 9. Refer to the Auto Switches Precautions (Web Catalog) if using with an auto switch. 10. Risk to people with pacemakers The product has a magnet inside. It may interfere with the use of an electronic equipment such as a pacemaker.

1 Fine Lock Cylinder with Guide Series MLGC 20, 25, 32, 40 A linear transfer cylinder unit with a built-in locking mechanism and a guide rod integrated in a compact design.

40 5.5 40 Since this is a guideline including hysteresis, not meant to be guaranteed.