A per branch: 20 m or less At 1.0 A per branch : 16 m or less At 1.5 A per branch : 10 m or less Branch cable length Insulating cap Brown Black White Blue 1: Input terminals are not isolated from Power source. 2: Do not connect outside Power source to Input and Output terminals.
applied to pneumatics only. 14-3-4 5 For details about certified products conforming to international standards, visit us at www.smcworld.com.
When fixing a work piece at the end of the piston rod, first retract the piston rod to the back end. Use the spanner hook at the end of the rod to keep the torque below the allowable tightening torque. 3. Always apply the piston rod load in the axial direction. Avoid operation where rotational torque is applied.
Note 6) The drawing shows these three dimensions when the adjustment bolt is lowered (when energy absorption is at its maximum).
Double vane CRB1BW10-lD CRB1BW15/20/30-lD/Dimensions below are based on size 20. /Dimensions below shows the middle locations of pressurization to A port or B port.
2110 20 21Direct Operated Precision Regulator (For Special Applications) Direct Operated Precision Regulator with Backflow Function (For Special Applications) Series ARP20K to ARP40K 10 20 2110 20 21-ARP20/ARP20K 10 20 21 -ARP30/ARP30K 10 20 21 -ARP40/ARP40K 10 20 21 Description Symbol Body size 20 30 40 Nil 1 Note 4) 3 Note 4) Set pressure c 0.005 to 0.4 MPa setting 0.005 to 0.2 MPa setting
Also, when the sealant tape is used, leave 1.5 to 2 thread ridges exposed at the end of the threads. 1. The valve has been lubricated for life at the factory, and does not require any further lubrication. 2. If a lubricant is used in the system, use class 1 turbine oil (no additive), ISO VG32. For details about lubricant manufacturers brands, refer to the SMC website.
It will causes malfunctions on control circuit that exhausts at both port such as 3 position valve with exhaust center.
Smooth Cylinder Minimum 0.01 to 0.03 MPa operating pressure Minimum Minimum 0.01 to 0.03 MPa operating pressure 0.04 Minimum operating pressure MPa 12 16 0.03 20 25 32 40 0.02 50 63 80 100 0.01 0 0 10 20 30 40 60 50 70 80 90 100 Bore size mm (Measurement based on JIS B8377) Series CQSY/CQ2Y/CM2Y/CG1Y/CA2Y 12 to 25 32 to 100 20 to 40 20 to 100 40 to 100 Stable operation possible even at a
Connection Female Thread: Rc, NPT, NPTF Uni thread size Wrench tightening angle after hand-tightening [deg] Tightening torque [Nm] 1/8 30 to 60 3 to 5 1/4 30 to 60 8 to 12 3/8 15 to 45 14 to 16 1/2 15 to 30 20 to 22 Connection thread size Proper tightening torque [Nm] NPT, R1/8 3 to 5 NPT, R1/4 8 to 12 NPT, R3/8 15 to 20 NPT, R1/2 20 to 25 Connection Female Thread: G Chamfered area for female
CBG1N Rubber bumper type CBG1N25-PS Locking at head or rod end CBG1N32-PS CBG1A20-PS 20 25 32 40 CBG1A20-PS CBG1A25-PS CBG1A32-PS CBG1A40-PS Above no. @5, @6, @7, @8, $0, $1. And a grease pack. CBG1A Air cushion type CBG1N40-PS CBG1A25-PS Locking at both ends CBG1A32-PS CBG1N20-PS-W CBG1A40-PS 20 25 32 40 CBG1N20-PS-W CBG1N25-PS-W CBG1N32-PS-W CBG1N40-PS-W Above no. @5, @6, @7, @8.
(The SI unit type is provided for use in Japan.) *6 p: For pipe thread type: NPT only *1 Options B, G, H are not assembled and supplied loose at the time of shipment. *2 Assembly of a bracket and set nuts (AR20-B to AR40-B) Including 2 mounting screws for the AR50-B and AR60-B *3 Mounting thread for pressure gauge: 1/8, Pressure gauge type: G46-20-l *4 For pipe thread type: NPT.
10 to 20 l/min Simple flow setting Without removing the cover, you can set with a screwdriver from the outside.
M4 hexagon socket head cap screw [Replacement Element] END400-005 (5 m Type) END400-020 (20 m Type) 4 elements are required per unit. Protection cover 2-3. Removing cylinder a. Remove the M8 hexagon nut at four parts. b. Remove the cylinder flange holding bolts. Holding bolt: M8 hexagon socket head cap screws at four parts up to the cylinder, and remove it.
M4 hexagon socket head cap screw [Replacement Element] END400-005 (5 m Type) END400-020 (20 m Type) 4 elements are required per unit. Protection cover 2-3. Removing cylinder a. Remove the M8 hexagon nut at four parts. b. Remove the cylinder flange holding bolts. Holding bolt: M8 hexagon socket head cap screws at four parts up to the cylinder, and remove it.
Note that power daisy chaining supports a maximum of 20 MPCs in one power group. This does not mean that you cannot have more than 20 MPCs connected to a single supply. More MPCs can be supported as long as the supply can source enough power to support multiple chains of MPCs. Each MPC uses about 7 watts of power when moving.
Mark C on the unit Mark B at cable end Mark A at cable end (1) (2) (3) End plate bracket (EX600-ZMA2) DIN rail mounting groove 1 Intermediate reinforcing brace (EX600-ZMB2) Intermediate reinforcing brace (EX600-ZMB1) Lock screw: No.4-40 UNC DIN rail 2 End plate bracket (EX600-ZMA2) 5 Connector pin assignment Digital input unit 3 4 3 2 1 1 0 EX600-DX B/DX D EX600-DX C 25 24 23 22 21 20 19
Mount an auto switch at the center of the operating range. In the case of 2-color display auto switch, mount it at the center of the green LED illuminating range. Adjust the mounting position of the auto switch so that the piston stops at the center of the operating range. (The mounting position shown in the catalog indicates the optimum position at stroke end.)
Switching element OFF Resistor Leakage voltage Valve Power supply Leakage current AC coil is 20% or less of rated voltage. DC coil is 3% or less of rated voltage. Selection 2. Low temperature operation Although the valve can be operated at a temperature as low as 0C, measures should be taken to avoid solidification or freezing of drainage and moisture, etc. Warning 1.