SMC Corporation of America
Elite Part Number Search
Search Results "ISE20-N-M5"

center C4 C6 M5 M Nil N Positive common Negative common 1 2 3 4 5 Nil R Internal pilot External pilot 5 6 24VDC 12VDC When an external pilot valve is to be used, enter a symbol in section (b) of the station table below.

1 2 3 4 5 6 7 Stations D-side 8 U-side M12 Female thread 2-C8 3(R) port 0 DIN rail clamp screw 1 62.5 60 (12) 40.5 25 9.5 7.5 18.5 M12 Male thread 20.5 (7.5) 2n-C3, C4, C6, M5 C3: 3.2 One-touch fitting C4: 4 One-touch fitting C6: 6 One-touch fitting M5: M5 thread 2-C8 1(P) port 34 P = 10.5 Formulas: L1 = 10.5n + 45, L2 = 10.5n + 93.5 n: Stations (maximum 16 stations) n L L1 L2 L3 L4 1 55.5

With blacket F C4 C6 One-touch fitting for 4 One-touch fitting for 6 M5 C3 C4 C6 M5 thread One-touch fitting for 3.2 One-touch fitting for 4 One-touch fitting for 6 DIN rail mounting (for manifold) D N Name plate Note) When specifying more than one option, please list alphabetically.

Type 40 Applicable solenoid valve SYJ514-SYJ514M-SYJ524-SYJ524M-How to Order SS3YJ5--40-05 -M5 R port 1/8 P port 1/8 P, R port thread type Stations A port size 02 : 20 2 stations : 20 stations Applicable blanking plate assembly SYJ500-10-3A Nil A A Rc G NPT NPTF M5 01 M5 x 0.8 1/8 F N T A port M5 x 0.8, 1/8 Note) For more than 9 stations, supply air to both sides of P port and exhaust air

DIN rail clamping screw 2n x C3, C4, M5 C3: 3.2 One-touch fitting assembly C4: 4 One-touch fitting assembly M5: M5 thread 2n x C3, C4, M5 C3: 3.2 One-touch fitting assembly C4: 4 One-touch fitting assembly M5: M5 thread 45.5 2.5 10.5 (5) Dimensions Formula L1 = 11n + 20 n: Station (Maximum 20 stations) 21.5 n L 1 2 3 4 5 6 7 8 9 10 L1 31 42 53 64 75 86 97 108 119 130 L2 50 62.5 75 87.5 100

+ 96 n: Stations (Maximum 12 stations) * Including 1 station for mounting terminal box.

1 2 3 4 5 6 7 Stations D-side 8 U-side M12 Female thread 2-C8 3(R) port 0 DIN rail clamp screw 1 62.5 60 (12) 40.5 25 9.5 7.5 18.5 M12 Male thread 20.5 (7.5) 2n-C3, C4, C6, M5 C3: 3.2 One-touch fitting C4: 4 One-touch fitting C6: 6 One-touch fitting M5: M5 thread 2-C8 1(P) port 34 P = 10.5 (mm) Formulas: L1 = 10.5n + 45, L2 = 10.5n + 93.5 n: Stations (maximum 16 stations) n L L1 L2 L3 L4

L M N NN P Q QQ R X Y U Model 2-3.4 through 2-6.5 counterbore with depth 3.3 4-M3 x 0.5 with depth 4.5 2-M4 x 0.7 with depth 7 2-M3 x 0.5 with depth 5 M3 x 0.5 x 10 46 17 44 15 7.5 2-M4 x 0.7 35 20 4 8 20 6 33.6 8.5 7 30 M5 x 0.8 x 5 CXS10 2-4.3 through 2-8 counterbore with depth 4.4 4-M4 x 0.7 with depth 5 M5 x 0.8 x 10 2-M4 x 0.7 with depth 6 2-M5 x 0.8 with depth 8 38.5 58 20 56 18 9

No indication is necessary for Rc; however, indicate N for NPT, and F for G. Separate interfaces are required for modular unit. T-interface (T) M5 x 0.8, 1/8, 1/4, 3/8, 1/2 Factory mounting of a piping adapter on the AC models is available as a special order. Using a T-interface facilitates the redirection of air flow.

Base mounted) Applicable solenoid valve SYJ540SYJ543SYJ550SYJ553Applicable blanking plate assembly SYJ5000-21-1A How to Order SS5YJ5 40 05 M5 P port 1/8 P, R port thread type Stations 02 2 stations Nil F N T Rc G NPT NPTF : : 20 20 stations R port 1/8 Applicable individual EXH spacer assembly A, B port M5 x 0.8 M5 M5 x 0.8 A, B port size Applicable individual SUP spacer assembly ARBYJ5000

(mm) <M5> <M5> Note) Weight (g) Model D1 P A M D2 L 2-applicable tubing M5 x 0.8 KJU23-M5 KJU23-01S KJU04-M5 KJU04-01S KJU06-M5 KJU06-01S 5.9 8.3 6.4 8.8 7.4 9.9 Reference dimensions after R thread installation.

io n ge io at of at ot ot R an R e n r ng tio ra ta n Ro io at ot R Unit Used as Flange Mount The L dimensions of this unit are shown in the table below.

(EA)5 1 (P) 3(EB) A 4 Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/ Pressure Sensors 3 position exhaust center Common specifications B 2 2(B) (A)4 4 Nil N Positive common Pilot type Negative common M5: M5 x 0.5 Nil R (EA)5 1 (P) 3(EB) Internal pilot When the SI unit specifications are PNP output ( COM), the common specifications of valves

(43) 2.5 (22.5) 0.5 2n-C3, C4, C6, M5 C3: One-touch fitting ass'y for 3 2n-C3, C4, C6, M5 VQZ C3: One-touch fitting ass'y for 3 C4: One-touch fitting ass'y for 4 C4: One-touch fitting ass'y for 4 C6: One-touch fitting ass'y for 6 M5: M5 thread C6: One-touch fitting ass'y for 6 M5: M5 thread VQD 45.5 2.5 10.5 (5) 21.5 VZS Dimensions Equation L1=11n+20 n: Staion ( Max. 24 stations) 7.5 L n

M5 X 40 l M5 X 45 l M5 X 50 l M5 X 55 l M5 X 60 l M5 X 65 l M5 X 70 l M5 X 75 l M5 X 80 l M5 X 85 l 40 45 50 55 60 65 70 75 80 85 M3 X 30 l M3 X 35 l M5 X 40 l M3 X 45 l M5 X 50 l M3 X 55 l 30 35 40 45 50 55 6.5 8.5 Note 1) The appropriate plain washer must be used for through-hole mounting.

This could cause an auto switch malfunction. 0.3 35.7 37 5.5 5.5 10 K 21 NA x M5 x 0.8 thread depth 6.5 5.5 10 KA 21 M 30 3 x M6 x 1 thread depth 10 5H9 ( ) depth 5 +0.030 0 14 2 N 1 x F 6.5 41 4 x M5 x 0.8 thread depth 7 12.5 (Extension end adjuster) F 3.5 49 1 24 14.5 24.5 24.5 28 29 58 6 Retraction end adjuster 5H9 ( ) depth 5 +0.030 0 11 5.5 N x M5 x 0.8 thread depth 6 Note 1) Note 2

Confirm that the external force is 20 [N] or less.

pitch N x P U 20 N 5 C (5.1) 10 5.8 4 5.5 36 1 0.2 6.5 6.5 1 3 39 28 10.5 3.3 T-slot A Body mounting reference plane +0.030 0 depth 4 +0.030 0 depth 4 C 4H9 L-M6 Refer to Cross section C-C.