Applicable shaft type: J Equal dimensions are indicated by the same marker. Applicable shaft types: K, T Equal dimensions are indicated by the same marker.
On the other hand, tightening below the range of tightening torque may allow the auto switch to slip out of position. (3) Do not carry a rotary actuator by the auto switch lead wires. Never carry a rotary actuator by its lead wires.
Do not carry a cylinder by the auto switch lead wires. Never carry a cylinder by its lead wires. This may not only cause broken lead wires, but it may cause internal elements of the switch to be damaged by the stress. 3. Mount switches using the proper tightening torque.
(actuation port [2]-(7) is released) Conversely, by applying pressure to actuation port [2]-(7), the piston (8), sealed by the cylinder seal (13) and the piston seal (9), is operated closing the valve (15) which is sealed by the valve seal (14).
R2 side by mounting a reverse pressure spacer.
construction and discharging by relief port directly to the outside of clean room.
the following formula which is based on the test conducted by the test circuit analogous to ISO 6358.
1 manually counterclockwise lowers the piston u, and causes the seal created by the seal !
However, it is still necessary to avoid reversed connections, since the auto switch could be damaged by a load short circuit in this condition. 2) If connections are reversed (power supply line + and power supply line) on a 3-wire type auto switch, the auto switch will be protected by a protection circuit.
Release pressure inside the filter completely by loosening the air vent plug. 1-3. Discharge fluid inside the filter by removing the drain plug. 1-4. Remove the stopper from the retainer by loosening the wing bolt on the V-band. 2-1. Make sure that O-rings are not damaged or deformed. If needed, replace with new ones. 2-2.
The braking force is released as the steel balls are removed from the taper ring by the ball retainer.
Design so that human injury and/or damage to machinery and equipment will not be caused by operation of a rotary actuator when machinery is stopped by a manual emergency stop or by a safety device under abnormal conditions, such as a power outage. 9. Consider the action when operation is restarted after an emergency stop or abnormal stop.
As a Socket case Hold surely by inserting the both of tube and barb. Possible to connect in the required position by the convex and concave for engagement. result, separate transportation of panel Plug and machinery equipment and backup Easy insertion of tube by the floating mechanism to adjust to the case hole. unit exchange are made possible.
Design minimizes influences of unlocking air quality A structure largely unaffected by factors such as condensate and moisture in compressed air has been realized by separating the locking mechanism and the unlocking chamber.
Release pressure inside the filter completely by loosening the air vent plug. 1-3. Discharge fluid inside the filter by removing the drain plug. 1-4. Remove the stopper from the retainer by loosening the wing bolt on the V-band. 2-1. Make sure that O-rings are not damaged or deformed. If needed, replace with new ones. 2-2.
This is affected by factors such as leakage in pipping, consumption by drain valves and pilot valves, etc., and reduction of air volume due to drops in temperature.
The manual has been written to be used by trained and competent personnel.
(power supply cut) GW unit reset by turning power OFF and back ON.
When the counter is reset by pressing the cylinder rod to the reference plane, that point becomes the home position.