SMC Corporation of America
Elite Part Number Search
Search Results "JSY5C03-5U-H"

H) Mount the removed drain port spacer. I) Rotate the new drain cock assembly in the direction shown by the arrow below by hand, and tighten it lightly. J) Rotate the lock nut by using a spanner or monkey wrench while lightly holding the internal assembly (chamber head). Tightening torque of the lock nut is 2Nm. H) I) J) Tightening torque 2Nm Tighten lightly.

O R LESS H YSTERESI S 0. 5% F. S. O R LESS PREPEATABI LI TY 0. 5% F. S. O R LESS SEN SI TI VI TY 0. 2% F. S.

ISE70/ISE75(H) ISE70/ISE75(H) ISE70/ISE75(H) () 1 ON ON OFF Yes No 2 OFF ON 1 OFF 3 4 5 -26No.PS-OMH0002CN-D 6 Yes No 7 7 8 9 10 11 12 13 14 15 -27No.PS-OMH0002CN-D No.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ZSP ISA2 IS ZSM PF2 IF Data Detection accuracy Model Detection distance Note) ISA2-G ISA2-H 0.01 to 0.25 mm 0.03 to 0.5 mm 0.01 mm or less Note) Detection distance: 0.01 to 0.15 mm (ISA2-G), 0.03 to 0.15 mm (ISA2-H) Supply pressure: At supply pressure

Material and insulation type Symbol Nil A G H L Body material Coil insulation type Seal material NBR FKM NBR FKM FKM C.O.

VXP2270-12-1G VXP Model Port size Electrical entry X36 DIN terminal or class H coil not available. 17-3-45 4 The VX series will be revised shortly. Series VXP21/22/23 Normally Open (N.O.)

Type 30 Passage pipe assembly VVCW20 2 C 1 01 Types 10, 20 VVDW 2 0 6A Material Brass Stainless steel C S Thread type Materials Series Symbol Nil A G H Rc G NPT Nil F N Pipe material 1 2 10 20 Seal material NBR FKM NBR FKM Stations Brass For 2 stations For 3 stations OUT port size 1 2 Stainless steel Symbol 01 02 Port size 1/8 (6A) 1/4 (8A) Type 30 VVCW20 6A Materials Symbol Nil A G H Seal

Vacuum pressure Suction flow rate 13-5-5 6 Series ZH Box Type (Built-in silencer): ZHB -S L One-touch connection Applicable tubing diameter B Model A 60 6 22 16 12.8 28 5 47 60 6 22 16 12.8 28 5 47 60 6 22 16 12.8 28 5 47 60 6 22 16 12.8 28 5 47 63 6 23 18 12.8 29 5 50 63 6 23 18 12.8 29 5 50 78 8 27.5 23 13.7 35 7 61 78 8 27.5 23 13.7 35 7 61 B C D E F G H ZH05BS-06-06 ZH05BL-06-06 ZH07BS

B 2-P (Piping port) G E G NN ( I ) D X NA R Mounting nut N W K N F S + Stroke F ZZ + Stroke H B E G Mounting nut NN NA F N 12CY3B15 (mm) L 57 66 70 80 92 J 6 6 8 8 10 K 11 8 10 15 16 I 12 15 18 23 G 5.5 7.5 7.5 8 11 H 13 20 20.5 22 29 F 10 13 13 16 16 E 2 2 2 2 3 NN M10 x 1 M20 x 1.5 M26 x 1.5 M26 x 1.5 M32 x 2 D 16.6 21.6 26.4 33.6 41.6 MM M4 x 0.7 M4 x 0.7 M5 x 0.8 M6 x 1 M6 x 1 B 35 36

Applicable bore (mm) A D L MM N R W B C H d Applicable bore (mm) Part no.

H-NBR Stainless steel POM The VHS series cannot be disassembled. Parts cannot be shipped separately. 5 Conforming to OSHA Standard Series VHS2510/3510/4510/5510 Pressure Relief 3 Port Valve with Locking Holes (Double Action) Dimensions VHS4510/5510 VHS3510 VHS2510 10 I EXH. H S U P EXH. H S EXH. U H S P U P G H F SUP. SUP.

Applicable cable O.D. 6 to 8 (D, DZ) P Pg9 J (DIN terminal: D, DZ) I (Grommet: G) F (Air operated) Pilot port 12 (P1) 2 x (Back side 10 (P2)) 4 x M 8 1 Manual override (Non-locking push type) P1 D S Q E 15 B A H (DIN terminal: D, DZ) G (Grommet: G) A R B C Main port 1 (A) (Back side 2 (B)) Port side: refer to table below Model Main port 1(A), 2(B) A B C D E F G H I J K L M N P Q R S VNB2V

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com With double shaft DD W D H 2 10 2-M5 x 0.8 (Port size) (US) (UW) BD Q BC M ab BA BA BB D (AU)Max.

Switch mounting screws (M3 x 0.5 x 10l) Switch spacer 32, 40 50, 63 RS H A Manufacture of Intermediate Stroke BQ-2 Method Spacers installed in standard stroke body. Switch mounting nut RZQ Ordering Refer to standard part number and ordering on page 10-10-2.

Applicable bore (mm) A D L MM N R W B C H d Applicable bore (mm) Part no.

For LEMC/H/HT Motor mounting position: Standard Motor mounting position: Symmetric A A Auto Switch Mounting LEMB Series LEMC/H/HT Series When mounting an auto switch, first hold the switch spacer with your fingers and push it into the slot. Confirm that it is aligned evenly within the slot and adjust the position if necessary.

thread effective depth C 4 x N through Q F 2 x M3 x 0.5 (Port size) I D M E Z L B + Stroke K A + Stroke M G J W 16 Minimum lead wire bending radius 10 Auto switch Q F 4 x N through H thread effective depth C 2 x M3 x 0.5 (Port size) I D M E Z L B + Stroke K A + Stroke M G J W Standard [mm] Bore size Stroke range Without magnet for auto switch With magnet for auto switch C D E F G H I J K

Open the tank lid and supply the circulating fluid up to the H mark on the tank. Fig. 4-6 Filling of Circulating Fluid Check the drain port is closed by the valve to prevent the supplied circulating fluid from draining out. Supply the circulating fluid up to the H mark on the tank.

No.1 , Byte0bit0IN0 =ON Byte0bit15 IN15=OFF 3Byte2bit47Byte3 bit07 No. bit ON bit OFF / 24V 0V ON 2 IN05 OFF SVON DRIVE DRIVE OFF 1 5 Min 15ms 3 4 ON BUSY OFF SVRE [] Byte2, bit6=ON Byte2,bit45=OFF Byte3,bit07=OFF (4)Byte5,bit01 Byte635 []50.00[mm] 5000[0.01mm]=(01388)h Byte8(LL)= (88) h Byte9(LH)= (13) h Byte10(HL)= (00) h Byte11(HH)= (00) h 5 bit Byte4 bit0 =ON ON 6Byte1bit0BUSY

Note 2) Not possible with bronze elements. 20 Port size Rc 2 Symbol Nominal filtration accuracy (m) Nominal filtration accuracy (m) 0.5 1 2 5 10 20 40 50 70 74 75 100 105 120 Symbol Element category X50 001 002 005 010 020 040 050 070 074 075 100 105 120 Material Element type 2 3 Bronze B S T G H P M L Sintered metal Stainless steel Polypropylene Glass fiber Cotton Cotton Stainless steel