VDC 6 VDC 5 VDC 3 VDC Power consumption Pressure specification Flow rate Power consumption (W) Maximum operating pressure (MPa) 0.1 0.3 0.3 0.5 0.1 0.3 Cv factor Symbol 0.021 0.011 0.021 0.011 0.011 0.006 A B C D E Note) 0.35 0.5 0.1 (With power saving circuit) F Note) Note) An option only applicable to 24 VDC plug lead type. 4-11-12 13 Series S070 3 Port Solenoid Valve Compact Direct
Standard Base mounted Universal External pilot Flow Characteristics/Weight Flow characteristics (1) Port size Valve model Weight (kg) Series 2 1 (A P) 1 2 (P A) 3 2 (R A) 2 3 (A R) C [dm3/(sbar)] 3.3 4.0 2.9/2.9 3.1/2.9 6.6 9.1 6.5/7.0 7.9/8.1 12 15 12/12 15/14 Cv 0.86 0.99 0.74/0.76 0.79/0.83 1.6 2.4 1.7/1.8 1.8/1.9 2.9 3.8 2.9/3.1 3.5/3.3 C [dm3/(sbar)] 3.4 3.7 3.3/3.6 4.1/4.1
Red 12 E 2 phase stepper motor PD Yellow 11 F 8 5 phase stepper motor For a signal power supply of 24VDC, connect an external resistor R (1.3k 1/2W) in order to hold the current to 15mA or lower.
(mm) TLM0201 2 x 1 2 1 TLM0302 3 x 2 3 2 TLM0425 4 x 2.5 4 2.5 TLM0403 4 x 3 4 3 TLM0604 6 x 4 6 4 TLM0806 8 x 6 8 6 TLM1075 10 x 7.5 10 7.5 TLM1008 10 x 8 10 8 TLM1209 12 x 9 12 9 TLM1210 12 x 10 12 10 TLM1916 19 x 16 19 16 TLM2522 25 x 22 25 22 TLM1613 16 x 13 16 13 Length per roll Color Translucent Translucent Symbol N N R BU B N N N 10 m Red (Translucent) 20 m Blue (Translucent) Roll
DIN terminal 4-15-12 13 3 Port Solenoid Valve Metal Seal, Body Ported/Base Mounted Series VZ400 Dimensions: Body Ported Grommet: VZ4 2-G H (S)-01 With foot bracket: VZ4 2--01-F 1 2 1 2 2-3.4 mounting hole 2-4.5 mounting hole M5 x 0.8 Pilot EXH V100 Manual override (Non-locking) SY Manual override (Locking type (Tool required)) Manual override (Locking type (Manual)) SYJ 2-3.4 mounting hole
Q1 5 4 () 1) () Q2 1)+COM (4) 7) (2)1U (3)J1,J2, Q2 (11) (P ) L L 0.3m 0 (M5x0.8) LO L 2 4 3 6 (5) 5 4 2) B (12) (2):1U 2)(3)Q1 8) (3)Q2 Assy N C 3) ) (6) ( D [kPa] (2):3M EA NPN2 9) 8) (PD) EB PNP2 0 to -100 EC NPN1 + S EE PNP1 + C FA NPN2 D FB PNP2 -100 to 100 8)VQ100 Ass yP.41 FC NPN1 + FE PNP1 + (3)Q2 (4)LO 9)(3)J1,J2Q2 P.6 (3)C 4) F 3) ZFC 4
(16 points) 16 0 EX600-DY *B (8 points) 0 8 Digital output unit EX600-DY *E (16 points) 0 16 (EX600 Series) DY EX600-DY *F (16 points) 0 16 EX600-DM *E (8/8 points) 8 8 Digital I/O unit (EX600 Series) DM EX600-DM *F (8/8 points) 8 8 Analog input unit AX EX600-AXA*1 (2 points) 32 0 Analog output unit AY EX600-AYA*1 (2 points) 0 32 Analog I/O unit AM EX600-AMB*1 (2/2 points) 32 32 *1: User
wire AWG#26) 3.5 27 6 26 23.5 20.5 3 9.5 28.5 3.5 4 Series S070 Dimensions Base mounted with screws S070B-G-M5 Grommet type 16.5 3 7 15 21 2-3.4 Mounting hole 150 (lead wire AWG#26) 22 5 6 22 20.5 3 2 1 11 7 6 5 12 12.3 12 25 M5 0.8 3 (EXH) port M5 0.8 2 (OUT) port M5 0.8 1 (SUP) port S070B-C-M5 Plug lead type 0.1 W with power saving circuit 6 150 (lead wire AWG#26) 3.5 27 27.5 25 22
In that case, loosen the screw with washer o and place a lead wire into the bracket , and then tighten it once again. b The maximum size for the round terminal o is 1.25 mm23.5 and for the Y terminal is 1.25 mm24. c Cable i outside diameter: 6 to 12 mm Note) For the one with outside diameter ranged between 9 to 12 remove the inside parts of the rubber seal u before using. 3.
-wire (PNP) 12 V 2-wire Relay, PLC 3-wire (NPN) 3-wire (PNP) IC circuit Grommet 5 V, 12 V 24 V Diagnostic indication (2-color indication) 2-wire 12 V 3-wire (NPN) 3-wire (PNP) IC circuit With timer 5 V, 12 V Lead wire length symbols: 0.5 mNil (Example) E76A 3 mL (Example) E76AL 5 mZ (Example) M5NTZ Solid state switches marked with are produced upon receipt of order.
AS420 Thread type AS500 AS600 AS800 Nil Rc NPT G N F 1 4 1 2 AS900 Needle Valve/Flow Characteristics Note) The flow characteristics are representative values.
-wire (PNP) 12 V 2-wire Relay, PLC 3-wire (NPN) 3-wire (PNP) IC circuit Grommet 5 V, 12 V 24 V Diagnostic indication (2-color indication) 2-wire 12 V 3-wire (NPN) 3-wire (PNP) IC circuit With timer 5 V, 12 V Lead wire length symbols: 0.5 mNil (Example) E76A 3 mL (Example) E76AL 5 mZ (Example) M5NTZ Solid state switches marked with are produced upon receipt of order.
Speed Controller with One-touch Fitting Elbow Type (Metal Body) AS Series AS-F AS-F Model TMH Speed controller with Applicable tubing O.D. Model Port size 4 6 8 10 12 ASD One-touch fittings for AS121-M5 AS221-01 AS221-02 AS321-02 AS321-03 AS421-04 M5 x 0.8 AS 1 8 R metal body specifications 1 4 R AS-FE 1 4 Uses flame resistant resin as standard.
Please consult with SMC separately for psi and F unit display specifications. Bowl assembly for the AFJ30 and AFJ40 models comes with a bowl guard (Material: Polycarbonate).
Example 1) When the pressure in the rear and the front of the cylinder differs: Example 2) When the air supply is cut off and releasing the inlet pressure to the atmosphere, the residual pressure release of the outlet side can be ensured for a safety purpose. 1 1 2 12 2 1 2 1 3 1 2 1 14 2 4 12 L 10 5 1 3 How to Order ARP 30 03 BE K Option / Semi-standard: Select one each for a to f.
Example 1) When the pressure in the rear and the front of the cylinder differs: Example 2) When the air supply is cut off and releasing the inlet pressure to the atmosphere, the residual pressure release of the outlet side can be ensured for a safety purpose. 1 1 2 12 2 1 2 1 3 1 2 1 14 2 4 12 L 10 5 1 3 How to Order ARP 30 03 BE K Option / Semi-standard: Select one each for a to f.
-mGm-m VX VNl VQ Dotted line: Bracket mounting style (-F) 4.3-9 Series VQ20/30 Dimensions/Series VQ30 DIN connector (Y) VQ31A1-mYmm-m Dotted line: Bracket mounting style (-F) 4.3-10 Series VQ20/30 For Dry Air, Pilot Operated 2 Port Solenoid Valve How to Order Manifold VV2Q 2 2 08 How to Order Manifold Assembly List valve and option part numbers under the manifold base part number.
Flame Resistant (Equivalent to UL-94 Standard V-0) Speed Controller with One-touch Fittings Elbow Type AS Series Model AS-F AS-F Minimizes installation time and cost Port size Applicable tubing O.D.
Without light SY100-61-1 With light Rated voltage Voltage symbol Part number 24 VDC 24 V SY100-61-3-05 12 VDC 12 V SY100-61-3-06 100 VAC 100 V SY100-61-2-01 200 VAC 200 V SY100-61-2-02 110 VAC 110 V SY100-61-2-03 220 VAC 220 V SY100-61-2-04