Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~1
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~1
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~1,
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~1
4.68 (0.26) C8: PA/B 12.6 (0.7) A/BR 12.6 (0.7) A, B port piping specifications SY3000 SY5000 SY3000 Operating pressure range External pilot operating pressure range MPa 2 position single Pilot pressure range 2 position double 0.25 to 0.7 Port size 3 position A/B ports Ambient and fluid temperature C Maximum 50 10 3 5 3 SY5000 2 position single, double 3 position Max. operating frequency
4.68 (0.26) C8: PA/B12.6 (0.7) A/BR 12.6 (0.7) SX5000 2 position single, double 3 position Max. operating frequency Hz Manual override Pilot exhaust SX3000 SX5000 Note 2) Valve effective area mm (Cv factor) Non-locking push type, Slotted locking type Pilot valve individual exhaust type Main valve, pilot valve common exhaust type Internal pilot External pilot 2 to 10 stations : W = 26n +
<br><br>
<br>※Refer to the manifold exploded view in the catalog for the part numbers for additional valve stations.
Refer to the following for the SY series manifold blanking plate assembly model: <br><br>
<br>② For manifolds with serial transmission kits, whether the valves are positive common or negative common depends on the type of protocol. For VQC1000/2000 series valves, install valves with the same common specification as the common specification of your protocol.
<br><br>
<br>Note) Consider using a VEX1□3□ series precision regulator for tension control or pressing control.
<br>Note 1) When port 2 (A) is retaining vacuum, there may be a decrease in vacuum power due to leakage from the vacuum pad and piping. Continue vacuuming at the vacuum suction position. <br>Note 2) This product cannot be used for emergency shut-off valves.
<br>Note 1) Air consumption is approx. 9.5 L/min (ANR) [at a supply pressure of 1.0 MPa]. <br>Note 2) If there is an abnormal amount of air leakage from the PE port, the diaphragm may be damaged.
<br>Note 1) The vacuum source for the VHK2 is piped to the 2 (A) side. <br>Note 2) Valve leakage is allowed for the VHK series.