Voltage to Operaie (on 60 cycles) DC 8090 B70h 13.2 13.2 OIRECT SOLEI{OIO OPERA'ED: The solenoid operates tho spool directly, and a spring returns the spool and solenoid plunger when the solenoid is de-enrgized RESFO SE Time to Energizq (Sconds) 0.018 0.017 o.ga 0.025 0.012 0.012 0.018 0.018 0.015 0.015 0.025 0.025 0.0r7 0.016 0.023 0.023 1r5/50 1n/@ 1 15/50 120r'@ The sOool has no seals,
~ ( 0 '" co; Port size 1/8' 1/4 Gauge '" U'" ~N Drain 45 40 M5 X O .8 With differential pressure type auto drain Optional Specification yJ Metal bowl 45 IN-OUT reversal mounting (-R) specification 9 Filter I Regulator Series AW it (mm) AW3001 .
Y200 AKM2000-01 (02) IS1000M-20 Y210-01 (02) AD17 Y100 AD48 AD47 AD38 AD37 Y300 AKM3000-(01) 02 IS1000M-30 Y310-(01) 02 AD38 AD48 auto drain AD17 AD27 AD37 AD47 Spacer Y100 Y200 Y300 Y400 Y500 Y600 Y400 AKM4000-(02) 03 IS1000M-40 Y410-(02) 03 02 VHS40-03 04 02 E400-03 04 06 02 IS1000E-4003 04 06 Y44-02 03 Y600 Y500 Check valve Note 6) Note 7) Pressure switch Note 7) IS1000M-60 IS1000M-50
Y200 AKM2000-01 (02) IS1000M-20 Y210-01 (02) AD17 Y100 AD48 AD47 AD38 AD37 Y300 AKM3000-(01) 02 IS1000M-30 Y310-(01) 02 AD38 AD48 auto drain AD17 AD27 AD37 AD47 Spacer Y100 Y200 Y300 Y400 Y500 Y600 Y400 AKM4000-(02) 03 IS1000M-40 Y410-(02) 03 02 VHS40-03 04 02 E400-03 04 06 02 IS1000E-4003 04 06 Y44-02 03 Y600 Y500 Check valve Note 6) Note 7) Pressure switch Note 7) IS1000M-60 IS1000M-50
Factory pressure settings from 3 to 50 psi, for extended life, higher setpoints can be attained for devices not requiring extended life. A variety of mounting options and port connections make the F-3000 Series an excellent choice for the O.E.M.
(2.5)] VFRA4311-04 3 8 VFRA4411-03 3 position exhaust center 1.2 1 8 PA, B: 51 (2.8) A, BEA, EB: 57.6 (3.2) [A, BEA, EB: 45 (2.5)] 1 2 VFRA4411-04 3 8 65 (3.6) [PA, B: 30.6 (1.7)] VFRA4511-03 3 position pressure center 1.2 1 8 VFRA4511-04 1 2 67 (3.7) [PA, B: 30.6 (1.7)] ( ): in case of normal position.
CAUTION 236 46 Cassette type Full MESK 49 532 Slit Valve XGT Series Dimensions Cassette type standard/XGT312 440 336 336 60 50 50 50 112 377 244 59 Valve seat side (XGT312, 313, and 311 common) Cassette type half MESK/XGT313 60 405 45 36 XLA XL 59 XLQ XM XY Non-cassette type/XGT311 D62 50 Opening size XSA 348 336 Opening size XVD XGT XGT 280 97 CYV 59 244 533 XGT Series Made to Order Specifications
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 2 to 50 Indoor Three phases 200 VAC (50/60 Hz) Three phases 200 VAC (50/60 Hz) Single phase 100 VAC (50/60 Hz) Single phase 200 VAC (50/60 Hz) Single phase 100 VAC (50/60 Hz) Three phases 200 VAC (50/60 Hz) Power source 90 130 0.4 0.45 1.44 1.4 50 60
Single vane Adjustment range of adjustment bolt (A) Adjustment range of adjustment bolt (B) 90 162 1 25 180 161 90 90 261.5 3 30 180 259.5 90 440 7 50 180 436 10 22.5 90 675 20 60 180 670.5 Positioning pin hole Allowable Load Adjustment bolt (A) Adjustment bolt (B) Do not permit the load and moment applied to the table to exceed the allowable values shown in the table below.
Effective area is larger than the former model. 6, 10, 16, 20 AS12l1F-M5 AS13l1F-M5 M5 X 0.8 6, 10, 16, 20 AS12l1F-U10/32 AS13l1F-U10/32 10-32UNF 20, 25, 32 AS22l1F-01 AS23l1F-01 R(PT)1/8 Tube swivels 360 20, 25, 32, 40 AS22l1F-02 AS23l1F-02 R(PT)1/4 40, 50, 63 AS32l1F-02 AS33l1F-02 R(PT)1/4 Universal style permits 360 piping swivel. 40, 50, 63 AS32l1F-03 AS33l1F-03 R(PT)3/8 63, 80, 100
Port size (A port) Rated voltage Option M5 M5 x 0.8 01 Rc 1 8 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz Nil None With bracket (Not assembled) P, R port: M5 4 5 6 24 VDC 12 VDC F Thread type 7 240 VAC, 50/60 Hz 9 Other Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800
/60Hz) Allowable voltage fluctuation 10% of rated voltage Coil insulation type Class H Power consumption W 50/60Hz VCS2: 4.9/4.1, VCS3: 7.7/6.6, VCS4: 10.5/9.3 Inrush VCS2: 22/19, VCS3: 36/30, VCS4: 45/37 Apparent power VA 50/60Hz Holding VCS2: 10/8, VCS3: 15/13, VCS4: 19/16 Note 1) In case of low pressure steam at a temperature of 120C or less, use FKM for the seal material.
D 5 3-4 IDH Series 52 5. 1 IDX-OM-W038 . 6 6.1 IDH4-10 IDH4-20 IDHA4-23 IDH6-10 IDH6-20 IDHA6-23 1),2) 100500L/min (ANR) 200800L/min (ANR) 540 0.31.0MPa 1535 (85%) 1530 0.150.85MPa 0.15MPa 400L/min (ANR) 600L/min (ANR) 0.7MPa 35 30 30 3) 10 4) 0.1 0.5 () 5) AC100V AC200V AC230V AC100V AC200V AC230V 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 4.2A 2.1A 2.1A 9.4A 4.8A
Refer to back page 50 for Safety Instructions and pages 3 to 12 for Common Precautions. Mounting Warning Caution 1. Before performing installation, removal, or stroke adjustment, make sure to cut the power supply to the equipment and verify that the equipment has stopped. 2.
/60Hz) Allowable voltage fluctuation 10% of rated voltage Coil insulation type Class H Power consumption W 50/60Hz VCS2: 4.9/4.1, VCS3: 7.7/6.6, VCS4: 10.5/9.3 Inrush VCS2: 22/19, VCS3: 36/30, VCS4: 45/37 Apparent power VA 50/60Hz Holding VCS2: 10/8, VCS3: 15/13, VCS4: 19/16 Note 1) In case of low pressure steam at a temperature of 120C or less, use FKM for the seal material.
protrudes by 1mm over the body. 200VAC (50/60Hz) 2 DZM 1 (AVL5000) 10 110 to 120VAC (50/60Hz) 3 Dimension AC20* to AC60* (mm) 220VAC (50/60Hz) 4 Option Model A1 A2 A3 No gauge Nil 24VDC 5 AC20* 41.5 43 67.5 Pressure gauge (Unit: MPa) G 12VDC 6 AC25* 55 57 78 Pressure gauge (Unit: MPa, psi) P Others 9 AC30* 55 57 78 Specifications AC40* 72.5 75 100.5 Piston B Switching Pressure (Close to
= 50 [mm] D-X L2 L1 20Data Item Load factor n Note 1.
] L2 = 50 [mm] D-X L2 L1 20Data Item Load factor n Note 1.
Dynamic moment Me3 We W L2 Review Me3. = 1/3 14.7 (50 + 27) 103 = 0.38 [Nm] 3a = Me3/Me3 max = 0.38/3 = 0.13 Central axis of guide A Me1 W We Me1 = 1/3 We(L1 + B) 103 = 1/3 14.7 (50 + 48) 103 L1 B = 0.48 [Nm] 3b = Me1/Me1 max = 0.48/3 = 0.16 Review Me1.
Standard strokes (mm) Bore sizes (mm) 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 32, 40 50, 63 80, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Example) For CQ2XB40-57D, an 18mm spacer is installed inside a standard stroke CQ2XB40-75D cylinder. Specific Product Precautions Be sure to read before handling. Refer to pages 15 to 24 for safety instructions and precautions.