Hysteresis 0.5 kPa Internal orifice 0.5 0.8 Supply voltage 12 to 24 VDC (Ripple 10% or less) Output type NPN open collector 30 V, 80 mA Indicator light ON: When output is ON.
Base mounted (With sub-plate) 75 (Without sub-plate 45) Rc(PT)1 /8 4.5 (0.25) SYJA524-01 N.O. SYJA712-01 N.C. Rc(PT)1 /8 9 (0.5) 80 Body ported SYJA722-01 N.O. Base mounted M5 X 0.8 Rc(PT) 1 /8, 1 /4 01 02 01 02 SYJA714N.C. Base mounted (With sub-plate) 130 (Without sub-plate 80) SYJA724N.O.
Low frequency operation Valves should be switched at least once every 30 days to prevent malfunction. (Use caution regarding the air supply.) 4. Manual override operation When the manual override is operated, connected equipment will be actuated. Confirm safety before operating.
Filtration 30 m ZQ107 0.7 ZQ110 1.0 13-9-1 2 Compact Vacuum Ejector Series ZQ How to Order ZQ1 07 5 D31 1U K1 L C Ejector unit Nozzle nominal size Check valve 05 07 10 Nil K None With check valve 0.5 0.7 1.0 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Note) The
Model Main port 1(A), 2(B) A B C D E F G H I J K L M N P Q R S T U VNB2-10A VNB2-15A VNB3-20A VNB4-25A 3 8 1 2 3 4 1 144.5 55 125.5 52 26 4.5 24.3 2.3 25 34 63 42 28 14 72.5 80.5 75 80 84.5 124 60.5 73 135.5 151.5 137 153 156 172 62 72 31 36 5.5 6.5 28.3 33.3 2.3 2.3 30 35 43 49 80 90 50 60 35 44 17.5 22 84 100 92 108 84 90 89 95 93.5 99.5 Port size: 10A, 15A, 20A, 25A Vacuum pilot K L N
Ambient and fluid temperature Response time (1) 30 ms or less (at the pressure of 0.5 MPa) Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)
Construction Precautions Mounting Bracket Assembly 4 2 Vertical Lateral Area 75% reduction Male thread Female thread Barb fitting (Applicable tubing: 2) One-touch fitting (Applicable tubing: 2) Female thread Barb fitting (Applicable tubing: 2) One-touch fitting (Applicable tubing: 2) 2 x 7 pcs. 4 x 7 pcs.
kW 125A 110 to 125 kW 150A 150 kW 220A 180 to 220 kW Port size 20 2BJIS 10k flange 30 3BJIS 10k flange 40 4BJIS 10k flange 14-20-10 3 Main Line Filter Series AFF Flow Characteristics/Select the model taking the max. flow capacity into consideration.
TB W Counterbore depth TC Inner cover holding screw Note) (mm) E 4 6 J M6 x 1 M10 x 1.5 LD 5.6 9.2 L 67 90 K 21 20 JK 10 12 HP 44 73.5 HL 37.6 63.3 HI 23 39 HA 23 39 H 45 75 G 10 9 F 12.5 25 EK 4 6 ED 9.5 13 C 6.4 10.2 B 10.5 16 A 8 12 Model CYV15 CYV32 +0.030 H9 0 +0.030 H9 0 Z 132 165 Y 2.5 3.5 W 69 115 TC 0.5 0.5 TB 15 22 TA 20 22.5 T 30 34 R 45 79.5 QW 48 83 Q 112 147 PC 10 12 PB 60 100
Specications [mm] Table 1 Cylinder Strokes Bore size Stroke 16 15, 20, 25, 30 20, 25 15, 20, 25, 30, 35, 40, 45, 50 32 to 63 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Ambient and uid temperature range 32 to 302F [0 to 150C] Seal material Fluororubber Grease Heat resistant grease Standard stroke See Table 1. Dimensions See below.
---I -~ _:_::-::: : ::-0.7ipa ~,,:-~~.'. "". 0~~1~00 ~~2~0~~~ ~ 0 30~0-4~OLO-~50~0~~60~0 0 1500 3000 4500 6000 7500 Air flow rate Qlmin (ANR) Air flow rate Qlmin (ANR) AMH350 AMH850 0.5MPa )7MPa I I // ",0.06I-Air pressure 0.3MPa '" 0.06 Inlel air pressure 0.3MPa / a. V o/pa ~pa ::;; a. V~V ::;; Q) /-Y :; ~0 . 04 '// ~ / /,/ ~ 0.04
Setting item Indication Item Setting and selection Setting range Disabled Operation continues during the alarm Communication alarm detection time 1 Alarm AL34 : Communication error 30 to 600sec 30sec Comm.
TB W Counter bore depth TC Inner cover holding screw Note) (mm) E 4 6 J M6 x 1 M10 x 1.5 LD 5.6 9.2 L 67 90 K 21 20 JK 10 12 HP 44 73.5 HL 37.6 63.3 HI 23 39 HA 23 39 H 45 75 G 10 9 F 12.5 25 EK 4 6 ED 9.5 13 C 6.4 10.2 B 10.5 16 A 8 12 Model CYV15 CYV32 +0.030 H9 0 +0.030 H9 0 Z 132 165 Y 2.5 3.5 W 69 115 TC 0.5 0.5 TB 15 22 TA 20 22.5 T 30 34 R 45 79.5 QW 48 83 Q 112 147 PC 10 12 PB 60
Lightweight: 30 g(LVM11)/34 g(LVM1R/LVM11) A Weight savings by adopting resin as a standard B Power consumption: 1 w(LVM11)/1.5 w(LVM1R/LVM11) LVM11 Applications: Various analytical and inspection equipment Analytical instruments for blood, urine, immune system, etc.
Setting range: 0.1/0.2/0.5/1/2/5/10/30/60 s (Initial value 1 s) * The analog input update time is set for every wireless Remote unit. (4) Output while upper communication is not established Sets the output action of the entire wireless system for when the CC-Link communication is disconnected. CLEAR: Clear the output. HOLD: Fix the output at the current value.
Max. operating pressure Note 1) 2R (MPa) One-touch fittings, Insert fittings, Self-align fittings, Miniature fittings Applicable fittings Note 1) Note 2) Min. bending radius 100 15 25 30 50 65 13 20 24 30 40 50 60 Min. bending radius (mm) Note 3) Fixed end Bending value (Reference) 75 12 20 23 40 48 10 15 18 23 30 40 45 40 to +100C, Water: 0 to +70C (No freezing) Nylon 12 Operating temperature
(Crimping tool: DXT170-75-1) 3. Attaching and detaching lead wires with sockets Attaching Push the socket into the square holes of the connector (with +, 1, 2, indication), and continue to push the sockets all the way in until they lock by hooking into the seats in the connector. (When they are pushed in their hooks open and they are locked automatically.)
) J (DIN terminal: D) G (Air operated) H (Grommet: G) I (Conduit: C) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Main port Main port Rc Pilot port Rc A B C D E F G H I J K L M Model VNB5-32A VNB6-40A VNB7-50A 1 8 1 4 1 4 1 4 1 2 1 1 2 77 96 113 53 60 74 26.5 30
VXZ2230 VXZ2232 VXZ2240 VXZ2242 VXZ2350 VXZ2352 VXZ2360 VXZ2362 H Y F X E W D U V C S T B K R A J N Q N 79.5 87.5 101.5 106.5 L 108 117 130 135 1 4 3 8 , 28 35 43 45 26 30 38 43 14 17 22 22 7.5 8.5 9 9 24 33 42 47 1.6 2.3 2.6 2.6 22 28 36 42 5.5 6.5 6.5 6.5 40 52 65 70 6 7 7 7 11 14 18 21 93 102 115.5 120.5 25 25 28 28 89 97 112 117 67 75 87 92 50 63 80 90 23 23 25.5 25.5 35 35 40 40 25.5