Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 225/85, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 225/85, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 225/110, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 225/110, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 250/135, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 260/110, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 260/110, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket:
Mounting: Both Ends Tapped, Bore Size: 50mm, Thread: NPT Thread, Full Stroke: 150mm, First Stroke: 100mm, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Vertical, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -
Mounting: Both Ends Tapped, Bore Size: 50mm, Thread: NPT Thread, Full Stroke: 300mm, First Stroke: 150mm, Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: -, Number: -
Mounting: Both Ends Tapped, Bore Size: 50mm, Thread: NPT Thread, Full Stroke: 300mm, First Stroke: 120mm, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: 3 pcs.
Mounting: A (Both Ends Tapped), Bore Size: 50mm, Thread: TN (NPT Thread), Full Stroke: 75mm, First Stroke: 40mm, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m)
Time Accumulated pulse output mode 50 msec Time -35No.LV50***-OMQ0002-G [F 2] Setting of OUT2 Set the output mode of OUT2.
() 5S/cm M12 M12 M12 M12 LFE LFE LFE LFE-1 1 1 1-A3 A3 A3 A3 AWG21 0.9 mm PVC 1.7 mm PVC 6 66 No.LFE*-OMY0008 ( ( ( ( ) ) ) ) LFE1 LFE2 0.02 0.02 0.015 0.015 [MPa] [MPa] [MPa] [MPa] [MPa] 0.01 0.01 0.005 0.005 0 0 0 20 40 60 80 100 [L/min] 0 5 10 15 20 [L/min] [L/min] [L/min] LFE3 0.02 0.015 [MPa] 0.01 0.005 0 0 50 100 150 200 [L/min] [L/min] 67 No.LFE*-OMY0008 IN IN IN IN ( ( ( (
Port size (A port) Rated voltage Option M5 M5 x 0.8 01 Rc 1 8 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz Nil None With bracket (Not assembled) P, R port: M5 4 5 6 24 VDC 12 VDC F Thread type 7 240 VAC, 50/60 Hz 9 Other Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800
Rated voltage G: Grommet (Lead wire length: 300 mm) D: DIN terminal DO: DIN terminal H: Grommet (Lead wire length: 600 mm) 50 60 1 2 3 100 VAC, Hz 200 VAC, Hz 110 VAC, Hz 220 VAC, Hz 24 VDC 12 VDC 240 VAC, Hz Other (Without connector) 50 60 50 60 50 60 4 5 6 7 50 60 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside
Rated voltage Electrical entry 2 200 VAC 50/60 Hz 1 100 VAC 50/60 Hz G Grommet C Conduit 3 110 VAC 50/60 Hz D DIN terminal 4 220 VAC 50/60 Hz T Conduit terminal 5 24 VDC Refer to the table (1) given below for availability. 6 12 VDC 7 240 VAC 50/60 Hz 8 48 VAC 50/60 Hz 9 Other (Contact us for inquiry) Refer to the table (1) given below for availability.
(Initial conditions) 200 0.05 32 SFE1 SFE3 Inlet pressure/Back pressure [MPa] 150 SFE5 0.04 25 100 SFE4 SFE7 95 20 0.03 50 10 0 0.02 0 100 200 300 400 500 600 700 800 Cylinder driving speed [mm/s] AN 0.01 AMC Example) Bore size: 32, Driving speed: 400 mm/s, Supply pressure: 0.5 MPaG 1. From the graph, exhaust flow rate is found to be 95 L/min (ANR). 2.
L-type block (75) (50) W R P Q Port size Weight (kg) d K W Y AE (mm) (75) (50) W J W (mm) 1/2B (04) 3/4B (06) 1B (08) 1 1/4B (10) 1 1/2B (12) 2B (16) 2 1/2B (20) 3B (24) 22.2 27.7 34.5 43.9 49.1 61.1 77.1 90.0 47 47 47 50 50 50 50 50 70 70 70 85 85 85 105 105 9 9 9 9 9 9 9 9 62 62 62 65 65 65 65 65 3.5 3.5 3.5 6.2 6.2 6.1 11.9 11.9 Port size Weight (kg) E J P Q Port size Weight (kg) E 69
(Values at the initial period) VT325-C VT325-G JIS Symbol Solenoid Specifications Grommet, Conduit, DIN terminal, Conduit terminal 100, 200 VAC, 50/60 Hz, 24 VDC 15 to +10% of rated voltage 75 VA 60 VA 27 VA 17 VA 12 W Electrical entry Coil rated voltage Allowable voltage fluctuation 50 Hz 60 Hz 50 Hz 60 Hz Inrush AC Apparent power (3) Holding DC Power consumption (3) Note 3) At rated voltage
0.04 0.04 0.02 0.02 Conditions: P1 = 0.5MPa Needle: One side fully open 0 0 2000 4000 6000 8000 0 0 50 100 150 200 Flow rate L/min (ANR) Flow rate L/min (ANR) AL20 Rc 1/4 AL50 Rc 1 0.1 0.1 P1 = 0.3MPa P1 = 0.5MPa P1 = 0.7MPa P1 = 0.7MPa A portion of the air introduced from the IN side pressurizes the lubricant inside the bowl.