When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
AMH X6 AMH X15 Body size Body size Options specification Options (Not available with element service indicator "T") Thread Accessories Thread Accessories Port size Port size Dimensions Dimensions Model Port size A 239 252 258 284 B 80 1/8, 1/4, 3/8 1/4, 3/8 1/2 3/8, 1/2 3/4 1/2, 3/4 1 3/4, 1 1, 11/2 11/2, 2 AMH150 AMH250 80 Model Connection A 240 260 300 380 B 256 300 349 496.5 AMH450 AMH550
Repetition Supply pressure: 1.0MPa Set pressure: 0.45MPa Pressure characteristics Flow characteristics 1000 1 900kPa 900 800kPa 800 Output deviation factor % F.S. 0.5 700kPa 700 Set pressure kPa 600kPa 600 Out 500kPa 500 0 400kPa 400 Return 300kPa 300 -0.5 200kPa 200 100kPa 100 50kPa 0.4 0.6 0.8 1.0 -1 0 1 2 3 4 5 6 0 7 1.2 Flow rate l/min (ANR) Supply pressure MPa Series ITV009 Repeatability
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
bore size 20 5 5 4 (Steel pipe I.D.) 4 3 2 7 6 5 4 3 2 20 30 40 50 60 80 100 200 300 400 500 2.8 Flow velocity inside pipe (m/s) Piston speed (mm/s) Viewing the chart: Example) The flow rate necessary to operate a 50 cylinder at a speed of 100mm/s is 12l/min.
Repetition Supply pressure: 1.0MPa Set pressure: 0.45MPa Pressure characteristics Flow characteristics 1000 1 900kPa 900 800kPa 800 Output deviation factor % F.S. 0.5 700kPa 700 Set pressure kPa 600kPa 600 Out 500kPa 500 0 400kPa 400 Return 300kPa 300 -0.5 200kPa 200 100kPa 100 50kPa 0.4 0.6 0.8 1.0 -1 0 1 2 3 4 5 6 0 7 1.2 Flow rate l/min (ANR) Supply pressure MPa Series ITV009 Repeatability
Set the total current capacity to 300 mA. 300 mA is the value applicable when all I/O signals are used. The current capacity can be decreased by reducing the number of I/O points. The illustration of the 24 V DC power supply is divided between input signal and output signal for convenience. However, they can be configured by one. 11.
Power supply is AC200V single phase (Note 4) Controller Forced Alarm forced stop stop ON OFF RA1 RA2 MC MC SK Driver Servo amplifier Servo motor NFB MC CNP1 L1 1-phase 200 to 230VAC CNP3 (Note 6) U 2 L2 U Motor [1] V 3 L3 V M N W 4 W 1 P1 (Note 1) P2 PE CNP2 P (Note 2) C [3] [2] D (Note 3) Encoder CN2 Encoder cable L11 L21 CN3 CN3 24VDC Forced stop EM1 DOCOM (Note 5) DOCOM DICOM (Note 5)
When set to the factory setting (Pn600 = 0), the DRIVERs built-in option has been used. 27 - When the external Regenerative resistors for power are used at the rated load ratio, the resistor temperature increases to between 200 C and 300 C. The resistors must be used at or below the rated values. Check with the manufacturer for the resistors load characteristics.
When set to the factory setting (Pn600 = 0), the DRIVERs built-in option has been used. 26 - When the external Regenerative resistors for power are used at the rated load ratio, the resistor temperature increases to between 200 C and 300 C. The resistors must be used at or below the rated values. Check with the manufacturer for the resistors load characteristics.
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN